manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. GE
  6. •
  7. Floodlight
  8. •
  9. GE SBF Wide Beam Floodlight User manual

GE SBF Wide Beam Floodlight User manual

This manual suits for next models

1

Other GE Floodlight manuals

GE PF-400 Powerflood User manual

GE

GE PF-400 Powerflood User manual

GE Evolve EFH1 User manual

GE

GE Evolve EFH1 User manual

GE Ultra Sport GEH-5897 User manual

GE

GE Ultra Sport GEH-5897 User manual

GE PF-154 User manual

GE

GE PF-154 User manual

GE Powerflood HLU User manual

GE

GE Powerflood HLU User manual

GE Current Evolve GEH-6033 User manual

GE

GE Current Evolve GEH-6033 User manual

GE Criterion GEH-5874 User manual

GE

GE Criterion GEH-5874 User manual

GE Evolve EFM1 User manual

GE

GE Evolve EFM1 User manual

GE Ultra Sport GRH-5736F User manual

GE

GE Ultra Sport GRH-5736F User manual

GE HLU Powerflood User manual

GE

GE HLU Powerflood User manual

GE UltraSport User manual

GE

GE UltraSport User manual

GE Evolve EFH1 User manual

GE

GE Evolve EFH1 User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

GEH-3873H
SBF®WideBeamFloodlight
SBNNarrowBeamFloodlight
WithHIDMediumBaseSocket
INSTRUCTIONS
READTHOROUGHLYBEFOREINSTALLING
GENERAL
This floodlight has been designed for use in outdoor
applications and should not be installed in areas of
limited ventilation or in high ambient temperature
enclosures. Best results will be obtained if installed and
maintained according to the following
recommendations.
UNPACKING
This luminaire has been packed so that no parts
should have been damaged during transit. Inspect to
confirm.
INSTALLATION
This floodlight is provided with a pre-wired 1/2-inch
NPT threaded swivel fitting for mounting to standard
wiring boxes or conduit (locknuts not provided). Contact
your local GE electrical distributor for information
regarding availability of accessories for other mounting
options; cross-arm mounting adaptor, flat surface adaptor
for mounting over 4-inch J-box, swivel/slipfitter adaptor
for mounting on 1-1/2-inch to 2- inch pipe and trunnion
mounting adaptor (threaded portion of swivel fitting
must be removed to install trunnion adaptor).
WARNING
Risk of electric shock
•Turn power off before servicing
–see instructions
CAUTION
Unit will fall if not installed properly
•Follow installation instructions
NOTE: THE FLOODLIGHT IS INTENDED TO BE
MOUNTED IN THE ORIENTATION SHOWN
ABOVE. DO NOT MOUNT OR OPERATE IN AN
INVERTED POSITION SUCH THAT LAMP IS
OPERATING IN A BASE-UP ORIENTATION AS
WATER CAN ENTER THE FIXTURE IF OPERATED
IN A WET ENVIRONMENT.
These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation
or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be
referred to GE Lighting Solutions.
gGE
Lighting Solutions
OK DO NOT INVERT
35-201578-91 (1/00)
NOTE: REMOVE SCREWS FROM WEEP HOLES IN
BACK OF THE FIXTURE WHEN FLOODLIGHT IS
AIMED UP (ABOVE HORIZONTAL). FAILURE TO
DO SO COULD RESULT IN WATER BEING
TRAPPED INSIDE FIXTURE.
Use only lamps specified on nameplate. Observe
lamp manufacturer’s recommendations and
restrictions on lamp operation, particularly ballast
type, burning position, etc.
Lamp Tightness – Medium Base Lamp: The lamp
should be tightened to a light firmness sufficient to
depress the center contact.
CAUTION: FOR METAL HALIDE VERSIONS OF THE
SBF WITH PHOTOCONTROLS AIMING IS RESTRICTED
BELOW 45 DEGREES. AIMING MORE THAN 45
DEGREES BELOW HORIZONTAL MAY LEAD TO
OVERHEATING OF FIXTURE COMPONENTS, VOIDING
UL LISTINGS AND MANUFACTURER'S WARRANTY.
Make all electrical connections in accordance with
the National Electrical Code and any applicable
local code requirements.
Verify that supply voltage is correct by comparing
it to nameplate.
Do not remove insulated connectors from wires
not needed for required voltage connection.
When changing voltage on reconnectable units,
move only the lead with the insulated connector.
IF SINGLE VOLTAGE:
CAUTION
Riskofburn
•Allow lamp/fixture to cool before
handling
WARNING
Riskofburn
•Do not touch operating luminaire
All single voltage ballasts are pre-wired such that
user need only connect the supply conductors.
IF MULTIVOLT: (120/208/240/277 volts)
Connect the ballast lead with the insulated terminal
to the desired voltage terminal as indicated on the
ballast terminal nameplate.
IF MULTIWATT:
Multiwatt ballasts are available in various combina-
tions of wattage. See wiring instructions on wiring
tag inside the luminaire.
MAINTENANCE
It will occasionally be necessary to clean the
luminaire to maintain light level. Frequency of cleaning
will depend on ambient dirt level and minimum light
level which is acceptable to user. Lens door should be
washed in a solution of warm water and any mild,
non-abrasive household detergent, rinsed with clean
water and wiped dry. Should optical assembly become
dirty on inside, wipe reflector and clean lens door in
above manner and replace any damaged gasket.
gGE Lighting Solutions is a subsidiary of the General Electric Company. Evolve and other trademarks belong to GE Lighting Solutions. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
16943533----888
AIMING LIMITATIONS FOR METAL HALIDE UNITS