Optional Undercounter Dimensions and Installation Information
Listed by
Underwriters
Laboratories
For answers to your Monogram,® GE Profile™or
GE®appliance questions, visit our website at
ge.com or call GE Answer Center®service,
800.626.2000.
Specification Created 5/10
220230
PT900DR
GE Profile™30" Built-In Single Wall Oven
Note: 36” ribbon cooktop are approved for use
over GE 30” single wall ovens only. 30” ribbon
cooktops are approved for use over GE 30” and
GE 27” single wall ovens. Refer to cooktop and
wall oven installation information packed with
products for current dimensional data.
Note: CleanDesign or Sealed Burner Gas
This installation is to achieve minimum gap
between bottom of countertop and control
panel. For this installation, the bottom trim will
not be flush with a typical 4” toe kick
Note: Cabinets installed adjacent to wall ovens
must have an adhesion spec of at least a 194°F
temperature rating.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
Dimension and installation information are shown in inches.
4-3/4"
to
5-1/4"
36" Typical
Countertop height
Power cord
30-3/4"
to
31-3/4"
1-1/2" MIN.
Free space
1-1/2" Typical countertop
Side View
22
27-5/16" MAX.
Cutout height
27-1/4" MIN.
Junction box(s) for
oven & radiant
cooktop 22"
from floor
Add suitable filler to match
adjacent cabinets when needed
to maintain toe kick alignment
30" Oven W/ Rad. Cktp.
5
24
25
Gas or electric cooktops may be installed
over this oven. See cooktop installation
instructions for cutout size. See label on
top of oven for approved cooktop models.
Gas (including the pressure regulator) and
electrical connections for gas cooktop must
be located in an adjacent accessible location.
For a 30" gas cooktop, the connections are
more conveniently made to the right.
120 Volt
Outlet
Gas
connection
Junction box
location
240/208V
36'' MIN.
4'' To 4-1/2 '' Toe kick allowable
Match toe kick height
front and two sides
22'' MIN. above
support platform
Top and/or side
fillers may be
necessary if unit
is positioned
between
existing cabinets
28-1/2'' MIN.
28-5/8'' MAX.
3/4'' Support
platform required
23-1/2" MIN.
Cutout depth
Allow 11/16''
overlap over side
edges of cutout
1-1/2"
Countertop
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
With Gas Cooktop
With Electric Cooktop
Note: For this installation, the bottom trim will not be flush with a
typical 4" toe kick.
Note: Cabinets installed adjacent to wall ovens must have an
adhesion spec of at least a 194°F temperature rating.