For answers to your Monogram,® GE Profile™or 
GE®appliance questions, visit our website at 
geappliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Revised 2/11 221218
Electrical Requirements: 240v/208v; 60Hz, 40A
Effective January 1, 1996, the National Electrical 
Code requires that new construction (not 
existing) utilize a 4-conductor connection to an 
electric range.
Receptacle Locations: Locally approved flexible 
service cord or conduit must be used because 
terminals are not accessible after range 
installation. See shaded area in drawing for 
location of electrical outlet box. Recommended 
outlet locations allow range to be installed 
directly against wall.
Note: 30" ranges conform to U.L. requirements 
for 0" spacing from adjacent walls below 
countertops. To reduce possibility of scorching 
walls, engineering recommends a minimum of 
1-1/2" spacing to allow for possible extended, 
high-heat, no-load heating element operation.
Installation information: Before installing, 
consult installation instructions packed with 
product for current dimensional data.
Optional accessories: Tall backguard JXS8055 
(Available at additional cost)
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation 
of the range.
Dimensions and Installation Information (in inches) 
C2S980SEMSS 
GE Café™30" Free-Standing Dual-Fuel Range with Baking Drawer
Product is shipped with 4-prong 
plug. Recommended outlet is 
a NEMA 14-50R receptacle.
7-1/2
8
9
4
30
3
3
3
2-1/4
2
NOTE: Make gas connections on 
the left side and electrical conections 
on the right side of the
cutout opening. Recommended acceptable 
electrical outlet area. Orient
the electrical receptacle so the
length is parallel to the floor.
Wall-Mounted
Recommended area 
for through-the-wall 
connection of pipe 
stub/shut-off valve.
Recommended area for
through-the-floor connection
of pipe stub/shut-off valve.
This area allows 
flush installation 
to rear wall.
Product is shipped with 4-prong 
plug. Recommended outlet is 
a NEMA 14-50R receptacle.
7-1/2
8
9
4
30
3
3
3
2-1/4
2
NOTE: Make gas connections on 
the left side and electrical conections 
on the right side of the
cutout opening. Recommended acceptable 
electrical outlet area. Orient
the electrical receptacle so the
length is parallel to the floor.
Wall-Mounted
Recommended area 
for through-the-wall 
connection of pipe 
stub/shut-off valve.
Recommended area for
through-the-floor connection
of pipe stub/shut-off valve.
This area allows 
flush installation 
to rear wall.
30"
26-1/2"
46-3/4"
36-1/4"+
_1/4*
*Dimension from floor to top of
 the cooktop. Floor to top of rear
 vent trim is 37-1/4”