gebatronic Cody Light HF 1/1 User manual

X0508 V1.0
Cody Light HF
1/1 1/2
GB
Assembly, connection and maintenance of the device
may only be executed by personnel trained accordingly.
At this the underlying national and local regulations have
to be observed.

Note: Optional Cody Universal Service ool
The Cody Universal gives you the possibility to program your Cody
Universal conveniently to your requirements.
LCD display shows you every programming step, including the # of a
used memory slot, relays settings etc.
It also allows you to delete RC transmitters directly by their used
memory slot.
Ref. 500.S U0.00
The Cody Light HF consists of a decoder and a control element.
These units are connected by a simple double-wire cable without
a special plug. The Cody Light HF is a modern and safe
alternative to traditional key switches. The Cody Light HF can
safely be used after programming the pass code. For opening or
closing of the door only a four or five digit numeral code (pass
code) has to be entered. fter correct input of the pass code and
pushing the button the drive is triggered by the potential free
relay contact.
Pass code:
The pass code is either a four or five digit numeral code, by which
you operate your door drive unit. You have the possibility to store
up to four different pass codes, which means that up to four
different persons with different pass codes can open the door. If
you are accompanied by another person when entering your
passing code you can at first press as many keys as you like
before you finally enter your code. This ensures that no other
person can notice your pass code.
The input of the pass code is confirmed by pressing the
button.
Device description

IP OMA IC:
Especially for garage doors the Cody Light HF is designed with
TIPTOM TIC timing. fter entering a pass code and within a period of
60 seconds (adjustable) this function allows you to control the door
with any key, except for the button, and without the need to enter
the pass code once again. This function, however, can be interrupted
prior to the expiration of the 60 seconds, by pressing the button.
Lock-out function:
If the lock-out function is activated, the Cody Light HF automatically
blocks any input for a set period after the input of a wrong pass code
which is signalled with a (3 beeps) sound signal.
The end of the blocking time is signalled by a long sound signal.
General reset
General reset
Put DIP switch 4 to
ON
Push reset button
on the PCB
> 5 sec.
Put DIP switch
back to OFF
All factory settings are restored by the general reset !
Factory settings (default settings):
all memory slots erased (except 00)
Tiptomatic time = 60 sec.
switching time = 1 sec.
lock-out time = 20 sec.

Mounting instructions
Interior mounting of the logic:
1. Put the screw-driver into the gap of the enclosure front, push the screw-driver up and
open the enclosure.
2. Remove the control PCB (which is force fitted to the inside of the enclosure).
3. Locate the screwed glands supplied (sealing nipple left side) in the
enclosure and replace the PCB. (Please ensure PCB is firmly in position)
4. Bore the fastening holes and fix the enclosure bracket at the wall.
5. The wires for the keyboard ensure through the left cable entry (sealing nipple), the wires
for the relay contact through the middle cable entry and the wires for the supply voltage ensure
through the right cable entry. Ensure tight seating of sealing nipple and cable gland, otherwise the
water-protection of the appliance cannot be assured.
6. ccording to connection diagram connect the wires to the corresponding terminals.
geba GmbH is released of its obligations regarding guarantee and product liability if – without prior
permission - the unit has been modified, or if the installation is unproper or not in accordance with our
instruction manual. The installer has to take care that the EMC-regulations are respected.
he taught-in transmitters of the selected relays are now all
deleted !
RC transmitter
Deleting of remote controls
Delete specific transmitter:
Set DIP of the
relay used
(1/2) to ON
Press the button of the
RC transmitter
> 5 sec.
Put all DIP to OFF
Press the reset
button on the
logic board
> 5 sec.
Put
DIP 4 to ON LED flashes
2x long
Delete all transmitters of a single relay:
Put all DIP to OFF
Put
DIP 4 to ON
Set DIP of the
relay used
(1/2) to ON
he specific transmitter is now deleted !

Assembly versions - potential free contacts
Cody Light HF 1 / 1 = X6
Cody Light HF 1 / 2 = X6 + X7
This product complies with:
EC Electromagnetic Compatibility Directives
EN 61000-6-1 08/2002
EN 61000-6-3 08/2002
Low Voltage Directive 2006/42/EC
echnical data
Supply voltage: 20-28V C/DC, 230-240 V C
Output: 250V C 5
Connections: 1.5 mm² max.
mbient temperature: -20 °C to +60 °C
RC transmitter
Put DIP 4 to ON
Press the desired
button on the remote
control LED flashes
1x long
Put DIP of the
relay used
(1 or 2 ) to ON
Put all DIP to OFF
he transmitter is programmed to the desired relay!
each-in of remote controls
Make sure before the teach-in that the optional wireless module is plugged in firmly at the logic board.
230/240V C

Creating a new pass code
Cody Light HF 1/1 (up to 4 pass code for the relay output)
The four possible pass codes are programmed in the easiest way.
There are four DIP switches on the logic unit (see picture below). These four DIP switches correspond
to the four memory slots for each pass code.
Cody Light HF 1/2 (maximum 2 pass codes for each relay output)
The stored pass codes with the DIP switches 1 and 2 activate the output relay 1
The stored pass codes with the DIP switches 3 and 4 activate the output relay 2
Deleting a pass code
Keypad Keypad
Enter 4 or 5
digit pass code sound signal
1x long
push
button
Set all DIP to
OFF
he new pass code is now saved!
he selected memory slot of the pass code
is now deleted!
sound signal
1x long
push
button
push
button
Set all DIP to
OFF
sound signal
1x long
Enter 4 or 5
digit pass code push
button
Entering a pass code
A correct code is detected; the corresponding relay is switched!
Before the actual pass code, you can press any other keys to prevent fraud.
If an incorrect pass code is entered, you will hear a sound signal (3 beeps).
Entering a new pass code is only possible after the lock-out period (factory: 20 sec.) which end is
signalled by a long sound signal.
Put DIP of the
desired memoy
slot to ON
Put DIP of the
desired memoy
slot to ON
This manual suits for next models
2
Table of contents