GEIGER GJ56 E14 Series User manual

1
www.geiger.de EN
EN
DE Original-Montage- und
Betriebsanleitung
Original assembly and
operating instructions
Notice originale de montage
et d’utilisation
Instrucciones originales de
instalación y funcionamiento
Istruzioni originali di installazione
e funzionamento
EN
FR
ES
IT
Venetian blind motor:
GEIGER GJ56.. E14 Perfection with electronic end stop
For Venetian blinds and exterior blinds

2Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
1. General information
Dear customer,
By purchasing a GEIGER motor you have decided on a quality product from GEIGER.
Thank you very much for your decision and the condence placed in us.
Before you put this drive into operation please observe the following safety instructions. It
serves for the prevention of danger and for the avoidance of personal injury and damage to
property.
The installation and operating instructions contain important information for the installer, the
specialist electrician and the user. Please pass on these instructions if you transfer the product.
These instructions should be kept by the user.
2. Guarantee
In the case of incorrect installation contrary to the installation and operating instructions and/
or constructional modication, the legal and contractual guarantee for property damage and
product liability lapses.
Index
1. General information ............................................................................2
2. Guarantee.............................................................................................2
3. Intended use ........................................................................................3
4. Safety instructions ..............................................................................3
5. Safety instructions for assembly.......................................................3
6. Assembly note.....................................................................................4
7. Installation instructions......................................................................5
8. Information for the specialist electrician ..........................................7
9. Setting of the end stops .....................................................................7
10. Calling up the different modes...........................................................8
11. Activate the programming mode ......................................................8
12. Programming/changing the end stops..............................................9
13. Correction of the end positions or the shade position..................10
14. Moving to the shade position...........................................................10
15. Activating the option mode .............................................................10
16. Referencing on the limit stop switch/torque ..................................10
17. Resetting to factory setting .............................................................11
18. Blocking detection and anti-freeze protection ...............................11
19. What to do if… ...................................................................................11
20. Declaration of conformity.................................................................12
21. Technical data....................................................................................13
22. Maintenance.......................................................................................13
23. Notes on waste disposal ..................................................................13

3
www.geiger.de EN
EN
3. Intended use
The motors of the model range GJ56.. E14 Perfection with electronic end stop are designed
exclusively for the operation of Venetian blinds.
The motors may not be used for the operation of roller grilles, garage doors, furniture and lifting
tools.
GJ 56 xx x
Design options
Torque in Nm
For head rails at least 56 mm
GEIGER Venetian blinds motor
4. Safety instructions
I ATTENTION: Important safety instructions. For personal safety,
it is important to follow these instructions. Please keep these
instructions for future reference.
fDo not allow children to play with stationary controls. Keep remote controls away
from children.
fThe installation is to be checked regularly for defective balance, signs of wear or
damaged cables and springs, if relevant.
fDo observe the moving sun protection system and keep persons away until it has
closed completely.
fWhen operating the manual release with the sun protection system open, please be
cautious as it can fall down quickly if springs or tapes wear off or are broken.
fDo not operate the device if operations such as, for example, window cleaning are to
be carried out in the vicinity.
fDisconnect the automatic controlled device from the mains power supply if opera-
tions such as, for example, window cleaning are being carried out in the vicinity.
fDuring operation observe the danger zone.
fDo not use the installation if people or objects are in the danger zone.
fUrgently shut down damaged installations until repair.
fUnconditionally shut down the unit during maintenance and cleaning operations.
fPinching and shearing points are to be avoided and must be secured.
fThis appliance can be used by children aged 8 and above and persons whose
physical, sensorial or mental capacities are impaired, or who have no experience or
know-how if they have been supervised or been given instructions on the use of the
appliance and if they understand the possible resulting dangers. Children are not
permitted to play with the device. Cleaning and maintenance should not be carried
out by children.
fThe rated sound pressure level is less than 70 dB(A).
fDisconnect the device from the mains power supply for maintenance and replace-
ment of parts.
If the motor is disconnected via a plug connection the operator must be able to
control - from any place to which it has access – that the plug is removed.
If this is not possible - due to design or installation - the disconnection from the
power supply must be ensured via locking in the disconnected position (e.g. isolator).
fThe motor tube can get very hot during prolonged use.
When working on the unit, do not touch the tube before it has cooled down.
5. Safety instructions for assembly
I ATTENTION: Important safety instructions. Follow all installation
instructions, as incorrect installation can lead to serious injuries.
fWhen mounting the motor without any mechanical protection of the driven parts and
of the tube which may become hot, the motor must be installed at a height of at least
2.5 m above the ground or of another level which provides access to the drive.

4Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
fBefore the motor is installed, all cables which are not needed are to be removed and
all equipment which is not needed for power-operated actuation is to be put out of
operation.
fThe actuating element of a manual release must be mounted at a height of less than
1.8 m.
fIf the motor is controlled by a switch or pushbutton, the switch or pushbutton must
be mounted within eyeshot of the motor. The switch or pushbutton must not be
located in the vicinity of moving parts. The height of installation must be at least
1.5mabovetheoor.
fPermanently installed control devices must be attached visibly.
fIn case of devices extending horizontally, a horizontal distance of at least 0.4 m must
berespectedbetweenthefullyextendedpartandanyotherxedelement.
fThe rated speed and the rated torque of the motor must be compatible with the
device.
fThe mounting accessories that are used must be designed in accordance with the
selected rated torque.
fGood technical knowledge and good mechanical skills are necessary for the motor
installation. Incorrect installation can lead to serious injury.
Electricalworkmustbecarriedoutbyaqualiedelectricianinaccordancewiththe
regulations in force locally.
fOnly use connecting cables that are suitable with the environmental conditions and
which meet the construction requirements. (see accessories catalogue)
fIf the device is not equipped with a connecting cable and a plug, or other means for
disconnecting from the mains with a contact opening on each pole according to the
conditions of the overvoltage category III for full disconnection, a disconnecting
device of this type must be incorporated into the permanently installed electrical
installation according to the wiring rules.
fDo not mount the connecting cables near hot surfaces.
fA plug for the disconnection of the motor from the power supply must be accessible
after installation.
fDamaged connecting cables must be replaced by GEIGER connecting cables of the
same type.
fThe device must be mounted as described in the installation instructions. Fixations
shall not be made with adhesives since they are regarded as unreliable.
6. Assembly note
When viewed from inside the room, the
power supply connection of the GJ56..
E14 Perfection is located on the left side.
The straps are wound on the winding
rollers from the outside.
The GJ56.. E14 Perfection must be
installed in alignment with the turning
bars.
It is important that the GJ56.. E14
Perfection is installed centrally. Please
make sure that the load is evenly
distributed.
Inclined installation:
The inclined installation is permitted till
45° maximum to level.
Electric mains
Inside the room
Direction OPEN

5
www.geiger.de EN
EN
7. Installation instructions
I Prior to installation please check to ensure there is no visible damage
to the motor like cracks or open cables.
I Beforexingpleasecheckthestrengthofthemasonryandofthe
surface.
Head rail opening at top:

6Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
Head rail opening at bottom:
i

7
www.geiger.de EN
EN
8. Information for the specialist electrician
H Caution: Important installation instructions.
Please follow all instructions since
incorrect installation can lead to
the destruction of the motor and the
switching unit.
• An unlocked switch must be used for operation
(simultaneous UP/DOWN command possible).
• The operations with the service clamps may be
accomplished only by an electrical specialist.
• Motors with electronic limit stops can be connected in
parallel.
• In this case the maximum load of the switching unit
must not be exceeded.
• When changing the running direction the switchover
must be effected through an off-position.
• When changing the running direction the switchover
time must be at least 0.2 s.
• With a three-phase network, please use the same
external conductor in order to control the UP and
DOWN directions.
• Connecting cables with plug connectors of the
Hirschmann Company are tested and approved with
couplings of the Hirschmann Company.
• In order to prevent a malfunction caused by coupling,
the supply line (ref. NYM) from the actuator/switch to
the motor must not exceed 100m in case of motors with
electronic end stops.
H Attention! Only use connecting cable
with GEIGER plug.
9. Setting of the end stops
General information
In order to set the end positions of the GJ56.. E14 Perfection motors, any setting switch can be
used that has a programming key or that allows a simultaneous UP/DOWN command. In this
case, the UP/DOWN keys must be activated simultaneously instead of the programming key.
The motor can also be operated with the limit stop switch and a standard switch.
Article number / GEIGER setting switch
M56F154 with service terminal (D), 4-wires
M56E399 Adapter cable with STAK3 and open cable ends
I Important: please observe the connecting diagram on the back of the
setting switch.
Factory setting
• The motor is set on the lower end position at the factory. The upper end stop is at the very
other end. (at least lower end stop + 200 motor rotations).
• The motor command is in normal operation.
• The referencing is enabled on delivery.
12 3
PE N
L1
N
PE
Electronic /
mechanical
limit stop
blue
brown (UP)
black (DOWN)
green/yellow
Mains: 230V / 50Hz

8Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
✎Note: If the motor is installed in a closed Venetian blind and if the
limit stop switch is used the motor can be operated without further
settings.
I If the factory setting has been carried out and if the programming
mode is activated, max. 100 revolutions can be done downwards.
Reset to factory settings for a further run downwards.
10. Calling up the different modes
11. Activate the programming mode
I Prerequisite: The motor is positioned between the upper and the
lower end position. The limit stop switch should not be pressed.
I The GJ56.. E14 Perfection can be set with any setting switch that
permits a simultaneous UP/DOWN command. In this case, the UP/
DOWN keys must be simultaneously pressed instead of the program-
ming key.
A) Activate the programming mode via limit stop switch
Activating the learning mode is effected by performing the following driving movements:
I Please note: a break of at least 5 seconds
must be observed between movements.
Press the PROG key of the limit stop switch or the UP/
DOWN keys simultaneously until, after about 3 seconds,
the drive conrms “end position programming activated”
(2 x UP-DOWN). Then release the key.
B) Activate the programming mode on
the motor
Activating the learning mode is done by pressing and
holding the limit switch and the DOWN key on the blind
switch. The motor moves for 1 second.
Keep both keys pressed for another 3 seconds. The motor
conrms with a short movement downwards.
Normal mode
UP + DOWN
command 3 … <6 sec.
6 … <20 sec.
20 … <30 sec.
>30 sec.
UP + DOWN
command
2x
UP-DOWN
UP + DOWN
command
UP + DOWN
command
Faulty
operation
Factory
Reset
3x
UP-DOWN Option mode
Learning mode
Factory
setting
4x
UP-DOWN
2 x
Press PROG key
for 3 seconds
UP-DOWN
PROG
PROG
5 sec1 sec 5 sec1 sec 5 sec1 sec1sec
breakUP –– ––––breakDOWN break
5 sec
–break
5 sec
–breakUP UP
Press key
+

9
www.geiger.de EN
EN
12. Programming/changing the end stops
I Learning and referencing can be realized on the limit stop switch
but also on torque if the system has been specially designed for this
purpose. In this case, the installation parts are extremely stressed.
Learning and referencing with torque shut-off must be separately
tested and released by the sun protection manufacturer.
The upper and lower end stops can be programmed
and changed independently of each other.
• Activate learning mode as described above.
• Move in the direction of the lower end position.
The motor briey interrupts the movement to indicate
that it is in programming mode.
• Press the PROG key or UP and DOWN keys
simultaneously for approx. 1 second to store the end
position. The drive conrms with a feedback signal
(1 x UP-DOWN).
• Now the blind can be moved to the desired shade
position. Once this is reached, the position is saved
by pressing the PROG key or the UP and DOWN keys
simultaneously for approx. 1 second. The drive conrms with a feedback signal
(1 x UP-DOWN).
• Move the blind to the desired upper end position. The motor briey interrupts the movement
to indicate that it is in the programming mode.
• The end position is saved by pressing the PROG key or the UP and DOWN keys
simultaneously for approx. 1 second. The drive conrms with a feedback (1 x UP-DOWN).
The programming mode is automatically terminated and changes to normal mode.
The referencing is automatically activated if the upper end position is programmed.
Note: when referencing, the motor runs over the set upper end position until the limit
stop switch or switches off (torque shut-off).
I If the upper end position is reprogrammed on position, after the
end position had been programmed on the limit stop switch/torque,
the referencing is automatically switched on. If the upper end posi-
tion is programmed on position again, the referencing remains swit-
ched off or on.
Limit stop switch or torque shut-off instead of upper end position
• If the direction UP should be turned off by the limit stop switch/torque, there is no need to
program the upper end stop. The blind moves every time till the limit stop switch/switches off
(torque shut-off) at top.
• If an upper end position is already programmed and you now want to switch off with the
limit stop switch/torque, the programming mode must be activated and the blind moved
against the limit stop switch/torque shut-off. The lower end position is unchanged and the
programming is completed.
• The motor is now always turned off by the limit stop switch/switches off (torque shut-off) at top.
PROG
PROG

10 Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
13. Correction of the end positions or the shade position
Changing an end position or the shade position is done in the same way as programming. If a
position is not to be changed, press the PROG key or the UP and DOWN keys simultaneously
to change to the next position.
14. Moving to the shade position
By pressing the UP and DOWN keys simultaneously, the blind is moved into the
shade position.
15. Activating the option mode
NOTE: The options can be activated via a setting switch or an unlocked
control switch.
Activating the option mode is achieved by performing the following driving movements:
I Please note: there must be a pause of at least 5 seconds between the
movements.
Then press and hold the PROG key or UP and DOWN keys simultaneously on the setting
switch. The drive reacts between 3 and 6 seconds (2 x UP-DOWN). Continue to hold down the
programming keys until, after approx. 6 to max. 20 seconds, the drive conrms the option mode
item with the feedback (3 x UP-DOWN).
Switching on referencing
Switch on the referencing by pressing the UP key. The motor moves in UP direction and
interrupts with 1 x Stop-Go. The motor changes to normal mode.
Switching off referencing
Press the DOWN key to switch off the referencing. The motor moves in DOWN direction and
interrupts with 2 x Stop-Go. The motor switches to normal mode.
Activate direct shade position
Pressing the UP and DOWN keys simultaneously for approx. 3 to 6 seconds activates the direct
shadow position. The motor conrms with 1 x UP-DOWN. The motor changes to
normal mode.
Activating the indirect shade position
Pressing the UP and DOWN keys simultaneously for approx. 6 sec. activates the indirect
shadow position. The motor conrms with 2 x UP-DOWN. The motor changes to
normal mode.
16. Referencing on the limit stop switch/torque
The referencing on the limit stop switch can compensate a possible drifting of the upper end
position due to the modied winding behaviour of the lifting tapes.
If the referencing has been activated (see below), the next UP run is done till the limit stop
switch/torque shut-off.
The variation in distance between the upper limit position and the limit stop switch is stored.
After 1, 5, 20 and then every 50 cycles on the upper end stop, the motor runs against the limit
stop switch in order to test if the variations in distance have changed. If this is the case, the
upper end position is readjusted.
The motor stops on the limit stop switch/at top by the reference runs.
5 sec1 sec 5 sec1 sec 5 sec1 sec1sec
breakUP –– ––––breakDOWN break
5 sec
–break
5 sec
–breakUP UP

11
www.geiger.de EN
EN
17. Resetting to factory setting
Activating the programming mode is achieved by performing the following driving movements:
I Please note: there must be a pause of at least 5 seconds between the
movements.
Press and hold the programming keys (programming key/UP and DOWN key/limit stop switch
and DOWN key). The drive reacts between 3 and 6 sec. (2 x UP-DOWN) , between 6 and
20 sec. (3 x UP-DOWN) and after 20 to < 30 sec. with 4 x UP-DOWN. As soon as the drive
starts the UP-DOWN 4 times, the programming keys can be released. After that, the drive is
reset to the factory setting and the referencing is switched on.
Please note: The position at which the drive was reset to factory setting is now dened as the
lower end position and can be adjusted by activating the learning mode.
18. Blocking detection and anti-freeze protection
The drive has a blockage detection in the UP direction. After a blockage detection
(e.g. due to freezing of the blind on the window sill), the UP direction is blocked.
The UP direction is released again by a short move command in the DOWN direction.
19. What to do if…
Problem Solution
Motor does not run. • Motor not plugged in.
Please check the plug connection.
• Check connecting cable for possible
damage.
• Check the mains voltage and allow the
cause of the voltage breakdown to be
tested by a specialist
electrician.
Instead of in the downwards direction,
motor runs upwards.
• The control leads are interchanged.
Exchange black/brown control leads.
Motor only runs in one
direction.
• Motor in the end position.
Run motor in the opposite direction.
Readjust the end positions, if necessary.
After running several times,
the motor breaks down and
no longer responds.
• The motor became too hot and has
switched off.
Try it again after a cooling time of about
15 min.
The blind is in the upper position,
actuates the limit stop switch and can
no longer be moved downwards.
• The motor was installed upside down or the
lower end position has been overrun and
the lift tapes were wound up incorrectly.
Allow free mobility of the limit stop switch.
Reset the end stops.
5 sec1 sec 5 sec1 sec 5 sec1 sec1sec
breakUP –– ––––breakDOWN break
5 sec
–break
5 sec
–breakUP UP

12 Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
20. Declaration of conformity
Current declarations of conformity are available under www.geiger.de
Schleifmühle 6 |D-74321 Bietigheim-Bissingen
Phone +49 (0) 7142 9380 |Fax +49 (0) 7142 938 230 |info@geiger.de |www.geiger.de
Sitz Bietigheim-Bissingen |Amtsgericht Stuttgart HRA 300591 | USt-IdNr. DE145002146
Komplementär: Geiger Verwaltungs-GmbH |Sitz Bietigheim-Bissingen |Amtsgericht Stuttgart HRB 300481
Geschäftsführer: Roland Kraus |WEEE-Reg.-Nr. DE47902323
Gerhard Geiger GmbH & Co. KG
300H0204
EU Declaration of Conformity
Bietigheim-Bissingen, 20.04.2022 Roland Kraus (General Manager)
Product designation:
Venetian blinds motor, motor for rolling shutters, motor for awnings
Type designation:
GJ56.., GR45.., GU45.., GSI56.., GB45.., GB35..
Applied directives:
2006/42/EG
2014/53/EU
2011/65/EU + (EU)2015/863 + (EU)2017/2102
Applied standards:
EN 60335-1:2012
EN 60335-1:2012/AC:2014
EN 60335-1:2012/A11:2014
EN 60335-1:2012/A13:2017
EN 60335-1:2012/A1:2019
EN 60335-1:2012/A14:2019
EN 60335-1:2012/A2:2019
EN 60335-2-97:2006+A11:2008+A2:2010+A12:2015
EN 62233:2008
EN 62233 Ber.1:2008
EN 55014-1:2017
EN 55014-2:2015
EN 61000-3-2:2019
EN 61000-3-3:2013
ETSI EN 301 489-1 V2.2.0(2017-03)
ETSI EN 301 489-3 V2.1.1(2019-03)
ETSI EN 300 220-2 V3.1.1(2017-02)
DIN EN IEC 63000:2019-05
Authorized representative for technical data:
Gerhard Geiger GmbH & Co. KG
Address:
Schleifmühle 6, D-74321 Bietigheim-Bissingen
en
Gerhard Geiger GmbH & Co. KG
Antriebstechnik
Schleifmühle 6
D-74321 Bietigheim-Bissingen
0422100W1518

13
www.geiger.de EN
EN
21. Technical data
Technical data GJ56.. E14 Perfection with electronic end stop
GJ5606k GJ56061) GJ5610 GJ5620
Voltage 230 V~/50 Hz
Current 0,40 A 0,40 A 0,60 A 0,85 A
Cos Phi (cosj)> 0,95
Inrush current (factor) x 1,2
Power 93 W 90 W 135 W 190 W
Torque 6 Nm 6 Nm 10 Nm 2 x 10 Nm
Speed 26 rpm
Protection class IP 54
Limit switch range 200 rotations
Operating mode S2 4 min. S2 6 min. S2 4 min. S2 4 min.
Length 324,5 mm 329,5 mm 334,5 mm 361,7 mm
Diameter 55 mm
Weight ca. 1,50 kg ca. 1,60 kg ca. 1,70 kg ca. 2,20 kg
Air humidity dry and non-condensing place
Storage temperature T = -15°C .. +70°C
1) Run-time optimized version
Subject to technical modifications. Please find information to the ambient temperature range of our
GEIGER motors under www.geiger.de
22. Maintenance
The drive is maintenance-free.
23. Notes on waste disposal
Recycling of packaging materials
In the interest of environmental protection, please contact your local government’s recycling or
solid waste management department to learn more about the services it provides.
Waste disposal of electric and electronic equipment
Electrical and electronic equipment must be collected and disposed of separately in accordance
with EU regulations.

14 Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN

15
www.geiger.de EN
EN

16 Gerhard Geiger GmbH & Co. KG | 100W2589 0323V000en
EN
EN
Table of contents