Genie WIP2FRTMTP User manual

Quick Start Guide
Please read these instructions carefully before operating the unit
and keep for further reference.
2MP HD Face Recognition,
Temperature Check and Face
Mask Detection Terminal
WIP2FRTMTP

ii
Intro Section
Please read this instruction carefully before operating the product and keep it for further
reference. All examples and pictures used here are for reference only.
The contents of this manual are subject to change without notice.
CAUTION:
• Please use our product according to the following safety instructions and warnings.
• Do not place the device in extremely hot, cold, dusty or damp locations.
• Do not expose it to high electromagnetic radiation.
• If the product does not work properly, please contact your dealer.
• Never attempt to disassemble the product yourself. We shall not be responsible for any
problems caused by unauthorised repair or maintenance.
• Do not drop the device or subject it to any physical shock.
• Keep away from liquid while in use.
• Do not touch the screen with sharp objects.
• If cleaning, please use clean cloth to wipe it gently, avoiding water or alcohol.

Contents
iii
1.0 Introduction..........................................................................................................4
1.1 Product Features...........................................................................................4
1.2 Product Dimensions.....................................................................................4
1.3 Package Contents ........................................................................................4
1.4 Specification ................................................................................................5
2.0 Cable Connection................................................................................................6
3.0 Overview..............................................................................................................7
4.0 Installation ...........................................................................................................8
4.1 Ambient Illumination Requirement..............................................................8
4.2 Installation ...................................................................................................8
4.3 Pole Mounting..............................................................................................9
4.4 Height Requirement....................................................................................10
5.0 Network Connection ...........................................................................................11

4
The Genie WIP2FRTMTP is a professional robust high quality HD camera system designed
to utilise any combination of human body temperature sensing, facial recognition and mask
detection screening for secure and safe access control and monitoring. Designed
especially for many applications such as schools, offices, hospitals, airports, railway,
factories and retail. The system is built to our usual high standards, accurate and extremely
flexible, and can be networked or operated in standalone mode. The WIP2FRTMTP is the
perfect system to enable any premises a safe and exceptionally secure access.
1.1 Product Features
• 8” LCD touch screen
• All metal surround ensuring excellent heat dissipation
• High-accuracy IR body temperature measurement
• Human-sounding voice prompt
• Non-contact body temperature measurement
• Real-time face mask detection
• Face liveness detection technology distinguishing real faces from non-real face spoof
attacks
• Highly accurate face recognition using deep learning algorithm
• Stand-alone device or networkable allowing AI information when used in conjunction
with the WNVR18P5SM smart management NVR
1.2 Product Dimensions
1.0 Introduction
138.6mm
Device Quick Start
Guide
CD
Tapping Screw×4
Screw (KM3*7)×6
Cable Cover
Drill
Template
Bracket
Plastic Plug ×4
L-Wrench
34.2mm
301.8mm
1.3 Package Contents

Quick Start Guide 2MP HD Face Recognition, Temperature Check and Face Mask Detection Terminal
5
1.4 Specification
Performance OS Embedded Linux
Storage 8GB DDR3, 16GB EMMC
Screen
Display Screen 8” LCD touch screen, Resolution: 1280 × 800, Contrast: 500:1
Brightness 500 Lux
Control Interface I2C
Temperature
Measurement
Temperature Measuring Range 32~43°C
Accuracy ± 0.3°C
Ideal Measuring Distance 25cm ~50cm
Face
Recognition
Sensor 1/2.8
Lens 2MP Dual Lens, f=3.97mm @ F1.6
Lens Mount M12
WDR 120db
Height Range of Face
Recognition 1.2m-2.2m (The recommended installation height is 1.45m, based on the tester’s height of 170cm)
Face Recognition Distance 0.3m-2m (The recommended face recognition distance is from 0.5m to 1m)
Recognition Mode Face: 1:N
Recognition Duration ≤ 0.5 s per person
Face Capacity 20,000
Recognition Accuracy 99.7%
Supplementary
Light
Fill-in Light Soft white light, IR light
White Light Distance 1–3m
Smart Linkage
Screen Wakeup Yes
Light Adjustment Yes
Snapshot Yes
Audio
Two-Way Talk Yes (Noise reduction and echo cancellation)
Audio Input 1CH built-in MIC
Audio Output Built-in speaker
Interface
Network Interface 10/100Mbps self-adaptive Ethernet port x1
Alarm Input 2CH
Alarm Output 2CH
Wiegand Interface Wiegand input / output (26/34)
RS485 RS485 x1 (Half duplex)
Door Lock Output Relay output, NO/NC (Optional), Delay setting supported
SD Card Interface 1 Micro SD card slot up to 128GB
USB Interface USB x1
Anti-Tamper Interface 1 button
Exit Button 1
Reset Button 1
Others
Power DC12V @ 1A
Power Management Screen sleep, screen protection
Power Consumption <12W
Environment Surge Protection and Voltage Transient Protection
Working Environment 16°C~35°C, <95% (Non-condensing)
Environment Protection Complies with Directive EU RoHS, WEEE (2012/19/EU), Directive 94/62/ EC and
REACH(EC1907/2006)
Certificate CE, FCC
Installation Wall Mount, Pole Mount, Embedded Installation, Desktop
Dimensions 301.8 × 138.6 × 34.2 mm
Weight Approximately 1.2Kg

6
Note:
* The wiegand terminal here is a wiegand input terminal. If you want to connect to an access controller, you
shall set the Wiegand direction to “Output”.
* The RS 485 interface of this device supports security module access. Once the security module is enabled, the
exit button and lock control will be invalid.
2.0 Cable Connection
2CH alarm output Lock interface RS485 2CH alarm input Wiegand interface Exit Button
Connector

7
3.0 Overview
White Fill
Light
IR Temperature
Measurement
Module
Infrared
Light
Cameras
Display
Screen
Speaker
Front Left Right Back
Micro SD
Card Slot
USB Port
Reset
Microphone
18-Pin
Interface
Power
Interface
Anti-Tamper
Button

8
4.1 Ambient Illumination Requirement
Make sure faces can be captured clearly.
Avoid direct sunlight and backlight .
The device should be at least 2 meters away from the light, and at least 3 meters away
from the window or door.
4.2 Installation
4.0 Installation
30°
30 °
3m
30 °
30 °
2m
Direct/indirect
sunlight through
window
Drill Template
Gang Box
Bracket
(KM3*7)
Screws
(KM3*7)
Screws
Cable Entry Cable Cover
Wall
1. Place the drill template onto the wall and
then drill the holes according to it.
2. Install the gang box on the wall. Secure
the bracket onto the wall with 4 screws.
3. Route and connect the cables and then
install the cable cover.
4. Hang the device onto the bracket hook
and then tighten the screws.

Quick Start Guide 2MP HD Face Recognition, Temperature Check and Face Mask Detection Terminal
9
4.3 Pole Mounting
Note: Pole mounting bracket is not supplied with the device by default.
Package Contents
Installation
1
2 3
7
8
4 5 6
Ø33.5
32.0
Rubber Plug
Bracket
Cut the hole on the
installation surface
according to the drill
template.
Install the pole and
then tighten the nut.
Installation
Surface
Nut
Rubber
Plug
4 Screws
(KM3*9)
Screw
0~25°
Route the cables.
Tighten the screw
with a L-shaped
screwdriver.
Connect the
cables.
Install the rubber
plug.
Attach the
device to
the bracket
with four
screws.
Loosen the
screw to
adjust the
angle of the
device.
L-Wrench Screw (KM3*9) x4
Drill Template

Quick Start Guide 2MP HD Face Recognition, Temperature Check and Face Mask Detection Terminal
10
4.4 Height Requirement
The recommended installation height (H) is from 1.30m to 1.45m which can cover
human height of 1.4m ~1.9m in the detection area. It can be adjusted according to the
actual scene.
The ideal temperature measuring distance ranges from 0.3m to 0.4m.
The ideal face recognition distance ranges from 0.5m to 1m.
H
0.3m
0.4m

11
5.0 Network Connection
1. Make sure that the device and the PC are well connected via LAN.
2. Find the IP-Tool from the CD and then install it in the computer. After that, run the IP
Tool as shown below.
3. Modify the IP address. The default IP address of this camera is 192.168.226.201. Click the
information of the camera listed in the above table to show the network information
on the right hand. Modify the IP address and gateway of the camera and make sure its
network address is in the same local network segment as that of the computer. Please
modify the IP address of your device according to the practical situation.
After modification, please enter the password of the administrator and click “Modify”
button to modify the settings.
The default password of the administrator is “123456”.
Double-click the camera listed in the IP-Tool or manually enter the IP address in
the address bar of the web browser to connect IP-CAM. Then follow directions to
download and install the plugin.
Enter the username and password in the login interface. The default username is admin,
the default password is 123456.
Table of contents
Other Genie Digital Camera manuals

Genie
Genie HDC222 User manual

Genie
Genie WHD8BVAF User manual

Genie
Genie WIPX4EB User manual

Genie
Genie GHDPIR User manual

Genie
Genie SSAHD2B User manual

Genie
Genie WAHD8162 User manual

Genie
Genie WAHD2EBVAF User manual

Genie
Genie GIPPIR User manual

Genie
Genie GEBV User manual

Genie
Genie MSC Series User manual

Genie
Genie WHD5EB User manual

Genie
Genie WHD8EB User manual

Genie
Genie WHD5EBVAF User manual

Genie
Genie HDMC221V2 User manual

Genie
Genie GHD190DV User manual

Genie
Genie PWIP4EB User manual

Genie
Genie WNVR416P5OAI User manual

Genie
Genie GIP2CMIR User manual

Genie
Genie WHD8EBVAF User manual

Genie
Genie GEB User manual