Overspeed Governor ALJO 2130
UCM
Maintenance and assembly instructions
4.4.- Mechanical reset.
When the overspeed governor is triggered, its rope is maintained in a locking position being required the displacement of the
car in the opposite direction of which the blocking was produced for the mechanical resetting.
4.5.- UCM blocking.
There is a 24 VDC solenoid (100%) which with current allows free rotation of the overspeed governor and without current
works on a cog wheel (in unison with the pulley of the overspeed governor) allowing detection of UCM (by activating the
contact for UCM detection), giving a signal to the control panel of stoppage of the car and in the case of this not being
sufficient the blocking of the overspeed governor and the activation of the safety gears. When the car is on the floor and with
open doors this solenoid should not have current.
5.- Tension Pulley.
The tension pulley 12.065.0A has been estimated to produce a tension on the safety gear in the ascent direction of at least
300 N. In descent the tension is over 600N. Other tension pulleys can be used, always when the minimum tension is
guaranteed on the axle of the tension pulley. The tension pulley has a contact to detect the loosening of cables, which is
activated when the pulley turns on lengthening the rope.
6.- Electrical assembly.
The current of the remote tripping device (see table). Maximum time of activated coil of 10 second, waiting time for next
activation of 30 seconds.
The current of the electroiman must be 24 VDC. Maximum consumption of 1,9 A.ED =100% If the electroiman has tension
the UCM system will be desactived. The positionning contact of the electromagnet, safety contact is made up of two switch
contacts, 1NC + 1NO. The NC closed electromagnet with current and UCM system desactivated the NC opened.
The electrical tripping device, safety contact, is composed of 1 contacts 1NC (manual reset) and 1 NC+1NO (automatically
reset) or 2NC (remote reset at 24 VDC with 4,2 A or 230 VAC with 0,5 A).
The electrical UCM device, safety contact, is composed of 2 contacts 1NC + 1 NO. If the UCM is not detected the NC will be
closed.
7.-Maintenance.
All the rotation axes of the overspeed governor and of the return pulley have autolubricating caps, which means that they do
not require any subsequent greasing or maintenance.
At the same time, greasing of the cable can reduce the adherence of the cable and the channel of the overspeed governor.
This could reduce the strength of the test pulley.
Two things should be kept in mind to avoid incorrect operation of the overspeed governor. First, mobile elements should be
kept clean to avoid possible mixfunction. The installer should ensure of the perfect condition. Second, although the
equipment leaves the factory finished to avoid corrosion, the installer should check the parts, and act where appropriate. The
maintenance company will determine the frequency of inspections, but they should take into account the atmosphere where
the equipment is installed.
8.- Responsibilities.
Gervall no se responsabiliza de los problemas derivados del no cumplimiento de los consejos y
prescripciones descriptos. Así mismo, no se hace responsable de la manipulación de los precintos.
Gervall will not be held responsible for any problems caused by the non-compliance of advice and
guidelines. At the same time, Gervall will not be responsible for any manipulation of seals.