Ghost Controls AXWK User manual

WIRELESS KEYPAD
AXWK INSTRUCTIONS
www.GhostControls.com
Made in China, Rev. 2016-07
2016 GHOST CONTROLS
NUMBER KEYS (0-9)
Use to enter numbers for
Master and Access PIN
PARTYMODETM OR 1KEYTM (ON/OFF)
Use with MASTER PIN to turn
PARTYMODE SECURETM or
1KEYTM function ON/OFF
PARTYMODE® (ON/OFF)
Use with MASTER PIN to
turn PARTYMODE function
ON/OFF
STATUS LED
Provides visual feedback
for programming and
entering pins
VACATION MODE® (ON/OFF)
Use with MASTER PIN to
turn VACATIONMODE®
function ON/OFF
PROGRAM
Use to enter programming
mode to perform various
programming operations
SEND
Press after your PIN
is entered to open
gate
UNDERSTANDING NORMAL KEYPAD BEEPS AND LED’S
SUCCESSFUL ENTRIES FAILED ENTRIES
LED’s will flash ON/OFF each time you press a
key indicating the keypad has accepted each entry Invalid Pin: LED flashes and buzzer beeps TWICE
then goes o. Retry till successful entry
LED will flash slowly and keypad lights will remain
on for 30 sec. if you have entered a valid PIN Invalid Programming: ALL LEDs and buzzer stay on
for 2 seconds then goes o. Retry till successful entry
TROUBLESHOOTING GUIDE
STATUS
LED LIGHT BUZZER DESCRIPTION
NORMAL MODE
OFF OFF OFF OFF OFF Unit in sleep mode
1 short
blink 1 short beep N/A N/A N/A When any key is pressed provides
visual and audio feedback
2 short blinks 2 short beeps N/A N/A N/A Unit enters sleep mode after 2
short blinks and beeps
ON for 2
seconds ON for 2
seconds N/A N/A N/A Too many PIN entry attemps. Unit
goes to shut down mode for 1 min.
N/A N/A ON OFF OFF is pressed, MASTER PIN entry
is expected next
N/A N/A OFF ON OFF
is pressed,MASTERPINentry is
expected next or keypad is already
operating in PARTYSECURETM or
1KEYTM mode.
N/A N/A OFF OFF ON is pressed, MASTERPIN entry
is expected next
PROGRAMMING MODE
3 short blinks 3 short
beeps
3 blinks and
stay ON
3 blinks and
stay ON
3 blinks and
stay ON
Successful initial entry into
PROGRAM mode (Program key
is pressed while unit is in sleep
mode). Unit will automatically
return to normal operation after
60 seconds of inactivity.
1 short
blink 1 short beep ON ON ON When any key is pressed to provide
visual and audio feedback
3 short blinks
PAUSE
2 short blinks
3 short blinks
PAUSE
2 short blinks
ON during
beeping
then OFF
ON during
beeping
then OFF
ON during
beeping
then OFF
Successful completed
programming sequence
ON for 2
seconds
ON for 2
seconds
ON then
OFF
ON then
OFF
ON then
OFF
Invalid entry during programming
mode. Programming is not
successful. Unit exits to
normal operation
FACTORY DEFAULT MEMORY
3 long blinks
PAUSE
2 short blinks
3 long blinks
PAUSE
2 short blinks
3 blinks 3 blinks 33 blinks
Unit’s PINs memory and setting
is in Factory Default Mode. No
other function is operational until
the unit is initialized. Please refer
to INITIAL SET-UP section to
initialize the unit
2 long blinks
PAUSE
2 short blinks
2 long blinks
PAUSE
2 short blinks
2 blinks 2 blinks 2 blinks
Unit’s RF transmitting code is still
at factory default (blank). Refer to
LEARN TRANSMITTER section
to program a transmitter’s code to
the keypad.
YOUR MASTER PIN #* _____________________ ACCESS PIN # _______________________
ACCESS PIN 2 # ____________________________ ACCESS PIN 3 # _____________________
ASSEMBLING YOUR KEYPAD IN 3 EASY STEPS
NOTE: Keypad housing must be removed and two (2) C batteries (not included) need to be installed
before programming or mounting keypad. Installing the batteries require you to unscrew the bottom
two screws and inserting the batteries.
* (DO NOT GIVE OUT MASTER PIN!)
BACK OF
HOUSING
1. 2. 3.

PROGRAMMING ADDITIONAL PINS FOR ACCESS
ADD AN ACCESS PIN USING YOUR NEW MASTER PIN XXXX Follow below:
X= master pin | ?= access pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
ADD A TEMPORARY PIN (this time based pin will not work after “DD” days) Follow below:
X= master pin | ?= temp pin | (SUCCESS= hearing 3 beeps, pause, 2 beeps)
ADD A USE BASED TEMPORARY PIN (this use based pin will not work after “UU” uses)
Follow below:
X= master pin | ?= use temp pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
DELETE AN ACCESS PIN (You can no longer use this pin to operate gate) Follow below:
X= master pin | ?= access pin deleting | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
REPLACE MASTER PIN (do not give out your master pin to allow access) Follow below:
X= master pin | N = new master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
PROGRAMMING SPECIAL FEATURES (CAN ONLY PROGRAM USING MASTER PIN)
PARTYMODE®(keeps gate open to allow access to property for a set time) When you
want to enable PARTYMODE®keep gate in open position and suspend gate’s auto-close feature
(if enabled), the gate opener will beep twice if there is an attempt to close the gate. This is to
indicate that PARTYMODE®is enabled, therefore gate cannot be closed. Follow steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
PARTYMODE SECURETM AND 1KEYTM (use any number key and send key to operate gate
to allow access) When you want to enable PARTYMODE SECURETM or 1KEYTM,any number key
and the SEND key will operate the gate without the need to enter an ACCESS pin. The
buttons green LED will stay on when any key is pressed to indicate the keypad is in
1KEYTM mode. Follow steps below:
X = master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
VACATIONMODE® (keeps gate closed NO access to
property) When you want to enable VACATIONMODE®to
keep gate in closed position (gate has to be closed to set). Gate
will beep twice if there is an attempt to open the gate. This is to
indicate that VACATIONMODE®is enabled and the gate can
not be opened. Follow steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
WARNING
Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
PROGRAMMING
All GHOST CONTROLS®Premium Keypads must be programmed with a 4-digit Master PIN
prior to operating the Gate Opener System so that the safety and security of your system is
maintained. Keypad will store up to 20 access pins, including the master access pin.
NOTE: Keypad will remain in programming mode for up to one minute between key presses to
allow adequate time to go through each step. If you happen to incorrectly press a key sequence
(such as SEND, SEND) then the keypad will immediately drop out of programming mode and
you will have to start back at Step 1 of that programming sequence.
SET TING UP YOUR MASTER PIN (DO NOT GIVE OUT MASTER PIN!)
YOUR DEFAULT FACTORY MASTER PIN=
1 REPLACE DEFAULT MASTER PIN TO A NEW 4DIGIT PIN NUMBER XXXX
(keep pin safe, don’t lose)
EX:
TEACHING YOUR REMOTE TO THE KEYPAD
The keypad will not transmit a signal to the gate opener controller until it has learned the unique
transmitting code from a programmed working remote transmitter that currently operates your gate
opener. The remote teaches the GhostCode to the keypad. Proper positioning of the transmitter to
the keypad is critical for this process to work. Please see diagram
and steps below.
1 ENTER MASTER PIN AND THEN 58 ON KEYPAD
2 POSITION REMOTE AND KEYPAD
(as shown in diagram)
3 PRESS & HOLD THE TRANSMITTER BUTTON
THAT OPERATES THE GATE UNTIL KEYPAD
“LEARNS” THE SIGNAL
(SUCCESS = hearing 3 beeps from keypad, pause, 2 beeps)
4 GATE SHOULD WORK USING YOUR KEYPAD
AND NEW MASTER PIN XXXX
OUTDOOR MOUNTING PEDESTAL
AXGN Accessory for mounting
keypad to post
PROGRAM
KEY NUMBER
KEY

PROGRAMMING ADDITIONAL PINS FOR ACCESS
ADD AN ACCESS PIN USING YOUR NEW MASTER PIN XXXX Follow below:
X= master pin | ?= access pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
ADD A TEMPORARY PIN (this time based pin will not work after “DD” days) Follow below:
X= master pin | ?= temp pin | (SUCCESS= hearing 3 beeps, pause, 2 beeps)
ADD A USE BASED TEMPORARY PIN (this use based pin will not work after “UU” uses)
Follow below:
X= master pin | ?= use temp pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
DELETE AN ACCESS PIN (You can no longer use this pin to operate gate) Follow below:
X= master pin | ?= access pin deleting | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
REPLACE MASTER PIN (do not give out your master pin to allow access) Follow below:
X= master pin | N = new master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
PROGRAMMING SPECIAL FEATURES (CAN ONLY PROGRAM USING MASTER PIN)
PARTYMODE®(keeps gate open to allow access to property for a set time) When you
want to enable PARTYMODE®keep gate in open position and suspend gate’s auto-close feature
(if enabled), the gate opener will beep twice if there is an attempt to close the gate. This is to
indicate that PARTYMODE®is enabled, therefore gate cannot be closed. Follow steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
PARTYMODE SECURETM AND 1KEYTM (use any number key and send key to operate gate
to allow access) When you want to enable PARTYMODE SECURETM or 1KEYTM, any number key
and the SEND key will operate the gate without the need to enter an ACCESS pin. The
buttons green LED will stay on when any key is pressed to indicate the keypad is in
1KEYTM mode. Follow steps below:
X = master pin | (SUCCESS = hearing 3 beeps, pause, 2 beeps)
VACATIONMODE® (keeps gate closed NO access to
property) When you want to enable VACATIONMODE®to
keep gate in closed position (gate has to be closed to set). Gate
will beep twice if there is an attempt to open the gate. This is to
indicate that VACATIONMODE®is enabled and the gate can
not be opened. Follow steps below:
X= master pin | (SUCCESS = hearing 2 beeps)
WARNING
Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
PROGRAMMING
All GHOST CONTROLS®Premium Keypads must be programmed with a 4-digit Master PIN
prior to operating the Gate Opener System so that the safety and security of your system is
maintained. Keypad will store up to 20 access pins, including the master access pin.
NOTE: Keypad will remain in programming mode for up to one minute between key presses to
allow adequate time to go through each step. If you happen to incorrectly press a key sequence
(such as SEND, SEND) then the keypad will immediately drop out of programming mode and
you will have to start back at Step 1 of that programming sequence.
SET TING UP YOUR M A STER PIN (DO NOT GIVE OUT MASTER PIN!)
YOUR DEFAULT FACTORY MASTER PIN=
1 REPLACE DEFAULT MASTER PIN TO A NEW 4DIGIT PIN NUMBER XXXX
(keep pin safe, don’t lose)
EX:
TEACHING YOUR REMOTE TO THE KEYPAD
The keypad will not transmit a signal to the gate opener controller until it has learned the unique
transmitting code from a programmed working remote transmitter that currently operates your gate
opener. The remote teaches the GhostCode to the keypad. Proper positioning of the transmitter to
the keypad is critical for this process to work. Please see diagram
and steps below.
1 ENTER MASTER PIN AND THEN 58 ON KEYPAD
2 POSITION REMOTE AND KEYPAD
(as shown in diagram)
3 PRESS & HOLD THE TRANSMITTER BUTTON
THAT OPERATES THE GATE UNTIL KEYPAD
“LEARNS” THE SIGNAL
(SUCCESS = hearing 3 beeps from keypad, pause, 2 beeps)
4 GATE SHOULD WORK USING YOUR KEYPAD
AND NEW MASTER PIN XXXX
OUTDOOR MOUNTING PEDESTAL
AXGN Accessory for mounting
keypad to post
PROGRAM
KEY NUMBER
KEY

WIRELESS KEYPAD
AXWK INSTRUCTIONS
www.GhostControls.com
Made in China, Rev. 2016-07
2016 GHOST CONTROLS
NUMBER KEYS (0-9)
Use to enter numbers for
Master and Access PIN
PARTYMODETM OR 1KEYTM (ON/OFF)
Use with MASTER PIN to turn
PARTYMODE SECURETM or
1KEYTM function ON/OFF
PARTYMODE® (ON/OFF)
Use with MASTER PIN to
turn PARTYMODE function
ON/OFF
STATUS LED
Provides visual feedback
for programming and
entering pins
VACATION MODE® (ON/OFF)
Use with MASTER PIN to
turn VACATIONMODE®
function ON/OFF
PROGRAM
Use to enter programming
mode to perform various
programming operations
SEND
Press after your PIN
is entered to open
gate
UNDERSTANDING NORMAL KEYPAD BEEPS AND LED’S
SUCCESSFUL ENTRIES FAILED ENTRIES
LED’s will flash ON/OFF each time you press a
key indicating the keypad has accepted each entry Invalid Pin: LED flashes and buzzer beeps TWICE
then goes o. Retry till successful entry
LED will flash slowly and keypad lights will remain
on for 30 sec. if you have entered a valid PIN Invalid Programming: ALL LEDs and buzzer stay on
for 2 seconds then goes o. Retry till successful entry
TROUBLESHOOTING GUIDE
STATUS
LED LIGHT BUZZER DESCRIPTION
NORMAL MODE
OFF OFF OFF OFF OFF Unit in sleep mode
1 short
blink 1 short beep N/A N/A N/A When any key is pressed provides
visual and audio feedback
2 short blinks 2 short beeps N/A N/A N/A Unit enters sleep mode after 2
short blinks and beeps
ON for 2
seconds ON for 2
seconds N/A N/A N/A Too many PIN entry attemps. Unit
goes to shut down mode for 1 min.
N/A N/A ON OFF OFF is pressed, MASTER PIN entry
is expected next
N/A N/A OFF ON OFF
is pressed,MASTERPINentry is
expected next or keypad is already
operating in PARTYSECURETM or
1KEYTM mode.
N/A N/A OFF OFF ON is pressed, MASTER PIN entry
is expected next
PROGRAMMING MODE
3 short blinks 3 short
beeps
3 blinks and
stay ON
3 blinks and
stay ON
3 blinks and
stay ON
Successful initial entry into
PROGRAM mode (Program key
is pressed while unit is in sleep
mode). Unit will automatically
return to normal operation after
60 seconds of inactivity.
1 short
blink 1 short beep ON ON ON When any key is pressed to provide
visual and audio feedback
3 short blinks
PAUSE
2 short blinks
3 short blinks
PAUSE
2 short blinks
ON during
beeping
then OFF
ON during
beeping
then OFF
ON during
beeping
then OFF
Successful completed
programming sequence
ON for 2
seconds
ON for 2
seconds
ON then
OFF
ON then
OFF
ON then
OFF
Invalid entry during programming
mode. Programming is not
successful. Unit exits to
normal operation
FACTORY DEFAULT MEMORY
3 long blinks
PAUSE
2 short blinks
3 long blinks
PAUSE
2 short blinks
3 blinks 3 blinks 33 blinks
Unit’s PINs memory and setting
is in Factory Default Mode. No
other function is operational until
the unit is initialized. Please refer
to INITIAL SET-UP section to
initialize the unit
2 long blinks
PAUSE
2 short blinks
2 long blinks
PAUSE
2 short blinks
2 blinks 2 blinks 2 blinks
Unit’s RF transmitting code is still
at factory default (blank). Refer to
LEARN TRANSMITTER section
to program a transmitter’s code to
the keypad.
YOUR MASTER PIN #* _____________________ ACCESS PIN # _______________________
ACCESS PIN 2 # ____________________________ ACCESS PIN 3 # _____________________
ASSEMBLING YOUR KEYPAD IN 3 EASY STEPS
NOTE: Keypad housing must be removed and two (2) C batteries (not included) need to be installed
before programming or mounting keypad. Installing the batteries require you to unscrew the bottom
two screws and inserting the batteries.
* (DO NOT GIVE OUT MASTER PIN!)
BACK OF
HOUSING
1. 2. 3.
Other manuals for AXWK
3
Table of contents
Other Ghost Controls Keypad manuals