DSC PowerSeries LCD5511 Guide

Using the LCD5511 Keypad
WARNING: Please refer to the System Instruction Manual for information on limita-
tions regarding product use and function and information on the limitations as to lia-
bility of the manufacturer.
The LCD5511
shows the status
of your security
system using an
LCD display,
along with fixed
symbols and
numbers.
This instruction
sheet describes
the basic fea-
tures of the key-
pad. For more
detailed informa-
tion on your se-
curity system
and how to use it, please read your system’s In-
struction Manual. Test system weekly and have
any system trouble conditions corrected by
your alarm installer.
1. Display
2. System Lights
Ready Light (Green)
If the Ready light is ON, the system is ready for
arming. The system cannot be armed unless
the Ready light is ON.
Armed Light (Red)
If the Armed light is ON, the system has been
armed successfully.
3. Number Pad
Use the number pad to enter your code, and to
access system functions. To exit a function and
return to the Ready state, press . To select
a function press .
4. Emergency Keys
NOTE: *(All Keypads) The Fire, Auxiliary and
Panic keys will NOT function unless programmed
by the installer. If these keys are in service and the
installer has enabled audible feedback, holding
down the key for two seconds will cause the keypad
sounder to beep indicating that the input has been
accepted and sent.
5. Function Buttons ( )
If your installer has enabled them, you can use
the function buttons to access the Stay arm,
Away arm, Door Chime features (your installer
may program other functions for these but-
tons). Press and hold the appropriate button
for two seconds. Refer to your Installation Man-
ual for more information on these features.
Using the LCD5511 Keypad
The LCD5511 works similarly to the other key-
pads described in your system’s Instruction
Manual. For more information on individual func-
tions, see your system’s Instruction Manual.
Viewing Open Zones
Before you can arm your system, all the zones
must be closed. If some zones are currently
open, the keypad will display , and the
Ready light will be off. To see the numbers of
the open zones, press . Before you try to arm
your system, go to the open zones and close all
doors and windows, and make sure no one is
present in zones with motion detectors.
Viewing Zones in Alarm Memory
If there is an alarm on your system the keypad
will display and will scroll the numbers of
the zones affected. To view zones in memory,
press .
AC is present Zone(s) open
Zone(s)
bypassed
System Trouble
Trouble display
Door Chime
System armed
in Away mode
System armed
in Stay mode
Alarm(s) in memory
Fire alarm(s) in memory
System armed
Night mode
Programming
in progress
Press and hold both keys simultaneously for
2 seconds to send the following messages:
Fire Message
Auxiliary Message
Panic Message
1. Display
2. System
Lights
3. Number
Pad
alarm shop
System Functions - Quick Reference
The following chart lists the basic functions of your system and the keys to press for each function.
NOTE: Some functions may not be available on your system. Ask your installer for more information.
To do this: Press this:
Arm system (Away): [access code], leave through entry/exit door OR press and
hold for 2 seconds (if enabled)
Arm system (Quick): (from Ready state)
Arm system (Stay): [Access Code], do not exit premises OR press and hold for 2
seconds(if enabled)
Arm system (No Entry Delay): [Access Code]
Bypass zones: [2-digit zone number(s)], to exit
Disarm system: [Access Code]
Exit premises when system
armed:
Reset smoke detectors:
Program access codes: Refer to “Programming Access Codes”in the Instruction Manual
Send Fire message: (press and hold both keys simultaneously for 2 seconds)
Send Auxiliary message: (press and hold both keys simultaneously for 2 seconds)
Send Panic message: (press and hold both keys simultaneously for 2 seconds)
Set system time and date: [Master Code] , enter current time (24-hr for-
mat: 00:00-23:59) and date (month/day/year) as 10 digits:
[hh:mm MMDDYY]
Silence alarm: [Access Code]
Turn auto-arm on/off: [master code]
Turn door chime on/off: to toggle on or off OR press for 2 seconds
(if enabled)
Turn on bypassed zones (if Stay
armed):
View alarm memory:
View troubles:
(Troubles indicated by numbers 1-8 on top of keypad dis-
play. See ‘Viewing Trouble Conditions’in Instruction Manual for list
of trouble definitions)
#
alarm shop

Other manuals for PowerSeries LCD5511

4

Other DSC Keypad manuals

DSC HS2LCDWF v1.0 User manual

DSC

DSC HS2LCDWF v1.0 User manual

DSC Power PK55 433 Series User manual

DSC

DSC Power PK55 433 Series User manual

DSC PK5 Series User manual

DSC

DSC PK5 Series User manual

DSC HS2LED Series User manual

DSC

DSC HS2LED Series User manual

DSC LCD5501Z32-900 User manual

DSC

DSC LCD5501Z32-900 User manual

DSC PC 4010 User manual

DSC

DSC PC 4010 User manual

DSC PK5500 User manual

DSC

DSC PK5500 User manual

DSC RF5501-433 User manual

DSC

DSC RF5501-433 User manual

DSC PowerSeries PTK5507 User manual

DSC

DSC PowerSeries PTK5507 User manual

DSC PowerSeries RFK5501 User manual

DSC

DSC PowerSeries RFK5501 User manual

DSC PowerSeries Neo User manual

DSC

DSC PowerSeries Neo User manual

DSC PC500 User manual

DSC

DSC PC500 User manual

DSC PowerSeries Neo HS2LCDWF User manual

DSC

DSC PowerSeries Neo HS2LCDWF User manual

DSC PowerSeries Neo HS2TCHP User manual

DSC

DSC PowerSeries Neo HS2TCHP User manual

DSC PK5500 User manual

DSC

DSC PK5500 User manual

DSC PowerSeries LCD5511 Quick start guide

DSC

DSC PowerSeries LCD5511 Quick start guide

DSC PK5500 User manual

DSC

DSC PK5500 User manual

DSC PowerSeries Neo User manual

DSC

DSC PowerSeries Neo User manual

DSC PK5500 User manual

DSC

DSC PK5500 User manual

DSC RF55O1-433 User manual

DSC

DSC RF55O1-433 User manual

DSC PowerSeries LCD5511 User manual

DSC

DSC PowerSeries LCD5511 User manual

DSC PC1000 User manual

DSC

DSC PC1000 User manual

DSC WT5500 User manual

DSC

DSC WT5500 User manual

DSC PC5532Z User manual

DSC

DSC PC5532Z User manual

Popular Keypad manuals by other brands

Genovation Micropad 630 Quick start quide

Genovation

Genovation Micropad 630 Quick start quide

AMX Metreau DAS-MET-6SRC datasheet

AMX

AMX Metreau DAS-MET-6SRC datasheet

Nexus Scoria Touch installation manual

Nexus

Nexus Scoria Touch installation manual

Abus PLBE10000 manual

Abus

Abus PLBE10000 manual

Paradox DigiplexNE DGP2-641 Reference and installation manual

Paradox

Paradox DigiplexNE DGP2-641 Reference and installation manual

Contro l4 C4-KC240 installation guide

Contro l4

Contro l4 C4-KC240 installation guide

US Automatic 050550 manual

US Automatic

US Automatic 050550 manual

Contro l4 Auxiliary C4-KA Series installation guide

Contro l4

Contro l4 Auxiliary C4-KA Series installation guide

Doorentryonline 596KP user manual

Doorentryonline

Doorentryonline 596KP user manual

Scantronic I-KP01 installation guide

Scantronic

Scantronic I-KP01 installation guide

Simons Voss PinCode-Terminal quick guide

Simons Voss

Simons Voss PinCode-Terminal quick guide

Connect IT CKB-0060-BK user manual

Connect IT

Connect IT CKB-0060-BK user manual

Contro l4 C4-KP2-Z installation guide

Contro l4

Contro l4 C4-KP2-Z installation guide

DMP Electronics Thinline 7060 installation guide

DMP Electronics

DMP Electronics Thinline 7060 installation guide

Climax Technology KPT-32 manual

Climax Technology

Climax Technology KPT-32 manual

Kyungwoo SMK TAG B PCB user manual

Kyungwoo

Kyungwoo SMK TAG B PCB user manual

Bosch D1265 user guide

Bosch

Bosch D1265 user guide

ANXELL E-Access E3AK5 instructions

ANXELL

ANXELL E-Access E3AK5 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.