WARNING: BEFORE PLUGGING IN THE UNIT OR TURNING THE UNIT ON/OFF, BE SURE TO
RESET THE VOLUME CONTROL KNOB TO ITS MINIMUM SETTING. STARTING THE UNIT AT ITS
MAXIMUM SETTING MAY DAMAGE THE FUSE.
The High-Frequency machine generates a current characterized by a high rate of oscillation. The current is
thermal (or heat producing), and germicidal. This current is also known as Tesla Current.
Included with this unit should be a pre-assembled complete handle and 4 glass electrodes.
OPERATION
A. Insert the electrode into the handle.
B. Turn on the machine by using the green toggle switch.
TIP: To avoid sparking, operators should first have the electrode in contact with the client’s skin
before turning on the power switch.
C. Use the intensity knob to adjust the power according to your client’s sensitivity.
a. To increase the power of the electrode, turn the knob clockwise.
b. To decrease the power of the electrode, turn the intensity knob counter clockwise.
D. During the process do not let the electrode jump then touch the area being treatment. This may
cause sparking.
E. When changing electrodes, adjust the intensity knob to MIN then turn power switch to the OFF
position. Remove the electrode from the holder and insert the desired electrode into the holder.
Turn the power switch to the ON position.
F. After treatment reset the intensity knob to its minimum position. Store in a cool dry place.
MAINTENANCE
Attachments should be sanitized after each use.
A. Wipe glass electrodes and attachments with rubbing alcohol and a soft cloth.
B. Dry electrodes and store in a sanitizer cabinet or autoclave.
TROUBLESHOOTING
When machine fails to work properly, use the following directions to detect the cause of the problem:
A. Check the power cord for proper connection.
B. Make sure the power switch is in the ON position.
C. Check the power source by connecting another electrical appliance to the AC outlet.
D. When a glass electrode does not glow, use another electrode to charge the dull electrode. Cross
the two like an “X” charging for 1 minute. After this process, both electrodes should glow. If the
electrode(s) still do not glow, the electrode(s) may need to be replaced.
E. If the problem persists, please contact your dealer for assistance.
F. To prevent an electrical shock, PLEASE DO NOT REMOVE THE COVER.
PARAGON®
203 HIGH FREQUENCY
ATTENTION Recommended for use by professional, state-licensed
estheticians. Operator shall be responsible for and damages to
him/herself, the machine, and/or clients.
Before installing and/or using this unit, please carefully read these
instructions. Be sure to keep this available for later reference.
REMOVE ALL JEWELRY PRIOR TO USING THE HIGH FREQUENCY.
HIGH FREQUENCY SHOULD NOT BE USED WHEN ON CLIENTS WHO ARE PREGNANT,
WHO MAY HAVE A PACE MAKER, OR THOSE WHO ARE EPILEPTIC.
NEVER USE ON AREAS MOISTENED WITH INFLAMMABLE LIQUIDS (ALCOHOL, ETHER,
ETC.) SPARKS COULD IGNITE THE LIQUIDS CAUSING SEVERE BURNS. THIS TYPE OF
LIQUID/LOTION CAN BE APPLIED AFTER ENDING USE OF HIGH FREQUENCY.