Liquid Level Sensor
7010 Liquid Level Sensor
gillsc.com
7010-30-083 Issue 2
Copyright © Gill Sensors & Controls
A few Do’s & Don’ts:
DO check you have the correct length of sensor for the tank, observing a minimum of 5mm clearance to the
bottom of the tank and clearance above for access.
DO check the sensor has the correct mounting ange (either 5 Bolt and 1.125”UNF, 5 Bolt & 1.25”BSP tting or
2” NPT tting) for the installation.
DO check the details to ensure you have a sensor with the correct output for your system (0-10V or 4-20mA).
DON’T attempt to cut the sensor to length or bend the sensor. Both actions will result in the sensor failing
and will invalidate the warranty.
DON’T use the sensor in a tank that is not adequately vented.
DON’T immerse the ange or cable in the liquid to be measured.
*Please note, images and diagrams in this document are for illustrative purposes only.
What you need to install this product:
1. A hole above the deepest part of the tank with the appropriate tting to match the sensor (5 Bolt,
UNF threaded, BSP threaded, NPT threaded).
2. O-ring or gasket dependant on model (supplied with the sensor)
3. PTFE or pipe sealant dependant on model (not supplied)
4. 5 x M5 bolts & xings (length dependant on tank wall thickness)
5. Adjustable spanner (50.0mm A/F for NPT version)
6. Torque wrench
Fitting the Sensor:
There are four dierent options for installing the sensor into the tank with three methods of sealing them.
These are as follows;
• 5 Bolt SAE mounting using the supplied gasket to seal the tank.
• 1.125” UNF threaded mounting with either the gasket or O-ring
• 1.25” BSP threaded mounting with either the gasket or O-ring
• 2” NPT threaded tting with either PTFE or pipe sealant.