GIRA
Info Instabus Binary input
Installation Instructions
Instabus Binary input 12/96 Page 2 of 2
Technische Daten
Supply instabus EIB: 24 V DC (+6 / -4 V)
Power drain instabus EIB: max. 150 mW
Connection
instabus EIB: Pressure contact on data bar
Inputs: Plug terminals 1 - 2,5 mm²
Ambient temperature: -5 °C to +45 °C
Storage temperature: -40 °C to +55 °C
Type of protection: IP 20
Build-in width: 35 mm (2 PU)
Binary Input 230V AC
Length of input lead: max. 100 m
Signal current: ca. 4 mA
Signal voltage
“0“ - signal: 0 to 100 V AC
“1“ - signal: 198 to 253 V AC
Signal duration: min. 70 ms
Binary Input 24V AC/DC
Length of input lead: max. 100 m
Signal current: 3,5 mA (AC); 6 mA (DC)
Signal voltage
“0“ - signal: 0 V to 5 V AC / -30 V to +5 V DC
“1“ - signal: 10 V to 30 V AC/DC
Signal duration: min. 50 ms
Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal provisions.
Please return the unit postage paid to our central service department giving a brief description
of the fault:
Gira
Giersiepen GmbH & Co. KG
Service Center
Dahlienstrasse 12
D-42477 Radevormwald
The CE sign is a free trade sign addressed exclusively to the authorities and does not include
any warranty of any properties.
Gira
Giersiepen GmbH & Co. KG
Postfach 1220
D-42461 Radevormwald
Telefon: +49 / 21 95 / 602 - 0
Telefax: +49 / 21 95 / 602 - 339
Internet: www.gira.de