•Installation
Make sure all parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector.
hooked onto the fit ting and secured to the framework, so that,
if the primary support system fails,the fitting falls as little as possible.
If the safety chain gets used, it needs to be replaced with a genuine spare.
The safety chain must be properly
•Minimum distance from flammable materials
The projector must be positIoned so that any flammable materials are at least 0.2 metres from
every point on the surface of the fitting.
•Mounting surfaces
It is permissible to mount the fitting on normally flammable surfaces.
•Maximum ambient temperature
Do not operate the fixt ℃ure if the ambient temperature (Ta) exceeds 33 .
•Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing ( appliance
according to standard EN 60598-1).
It is,moreover, recommended to protect the supply lines of the projectors from indirect contact and/or
shorting to earth by using appropriately sized residual current devices.
Class I
•Connection to mains supply
Connection to the electricity mains must be carried out by a qualified electrical installer.
Check that the mains frequency and voltage correspond to those for which the projector is designed
as given on the electrical data label.
This label also gives the input power to which you need to refer to evaluate the maximum number
of fittings to connect to the electricity line, in order to avoid ove rloading.
•Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting , in a thermally
steady state, is 45 .℃
•Maintenance
Before starting any maintenance work or cleaning the projector, cut off power from the mains supply.
After switching off, do not remove any parts of the fitting, to avoid getting burnt for at least 30 minutes.
After this time the likelihood of the lamp exploding is virtually nill.
The fitting is designed to hold in any splinters produced by a lamp explodin g. The lenses must be
mounted and, if visibly Damaged, they have to be replaced with genuine spares.
•Lamp
The fitting mounts a high-pressure lamp that needs an external igniter. This igniter is fitted onto the
apparatus.
-Carefully read the "operating instructions" provided by the lamp manufacturer.
-Immediately replace the lamp if damaged or deformed by heat.
•Battery
This product contains a rechargeable lead-acid battery. To preserve the environment, please dispose
the battery at the end of its life according to the regulation in force.
SAFETY INFORMATION
The products referred to in this manual conform to the European Community Directives to which
they are subject:
•Low Voltage 2006/95/CE
•Electromagnetic Compatibility 2004/108/CE
Pb
t 45
c
℃
2
t 33
a
℃
GLG Lighting