Global Industrial 761218 User manual

1
Wall Mounted Water Bottle Refilling Station
052120
globalindustrial.ca
User's manual Manual del usuario Manuel de l'utilisateur
Customer Service
US: 1-800-645-2986
Servicio de atención al Cliente
US: 1-800-645-2986
Service à la clientèle
Canada: 888-645-2986
WARNING
•Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
• For indoor commercial use only.
• All installation work must be performed by authorized
service personnel.
• Two or more people are recommended to lift and install
the unit.
• To avoid the risk of property damage and/or personal
injury, mount the unit to a flat finished wall surface with
adequate support.
• Check local codes for plumbing requirements prior
to installation.
• Prior to initial installation, install a shut-off valve (not
included) from the water supply.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the cooler. Failure to do so
will void warranty.
• Check for any leaks before initial operation.
• DO NOT attempt to repair or replace any part of your
appliance unless it is specifically recommended in
this manual. All other services should be referred to a
qualified technician.
• For use with clean, clear potable drinking water only.
• Shut-off water supply during installation to reduce risk
of water damage.
• Ensure proper ventilation by allowing appropriate
clearance of housing louvers to the wall on each side
of the cooler, as specified in rough-in guide.
•
NEVER wire the compressor directly to an electrical supply.
• DO NOT allow children to play with the appliance.
• Interior of unit may contain sharp edges. Wear gloves
when handling or servicing unit.
•
Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial
use only. Do not expose to freezing temperatures.
The grounding of electrical equipment to water lines is
a common procedure. This grounding may be in the
building or occur away from the building. This grounding
can cause electric feedback into the water cooler
creating an electrolysis which creates a metallic taste or
causes the water metal content to increase. Connect to
water supply using non-conductive materials.
Model 761218
Read this manual thoroughly prior to
installation, operation or maintenance.
Keep these instructions in a safe location
for future reference. For questions, visit
globalindustrial.com or contact Customer
Service at 1-800-645-2982.

User's Manual
Wall Mounted Water Bottle
Refilling Station
2
Risk of Electrical Shock
• Disconnect power before servicing unit.
• Electric supply must be identical in voltage, cycle and
phase to those specified in the specifications below.
Unit must be plugged into a GFCI outlet.
• Always pull the plug – not the cord – when disconnecting
from the outlet
• DO NOT use if the power cord is worn or damaged.
Power cords should only be replaced by qualified
service technicians using genuine replacement parts.
• Check local codes for electrical requirements.
• DO NOT disassemble or modify unit.
• Use Global Industrial filters only – Model 670336
Note:
• Prior to installation, consult with local, state, and federal
codes for proper mounting height.
• All installation and service should only be performed by
authorized personnel.
• Dimensions shown below comply with ADA requirements
at time of printing.
• Allow 4" minimum clearance on both sides to allow for
proper ventilation through cabinet louvers.
• Thoroughly flush all water lines and fittings of all foreign
matter before connecting to the Cooling System.
Failure to do so will void warranty.
Required Tools:
1. Safety Glasses
2. Safety Gloves
3. Electric Drill
4. Phillips Head Screwdriver
5. Flathead Screwdriver
6. Tape Measure
7. Pencil
8. Level Device
9. (11) 75-lb. Capacity Flat Head Wall Anchors
(appropriate for your wall type)
10.(11) Flat Head Anchor Screws
WARNING
•Review manual thoroughly and verify rough-ins before
installation. Keep these instructions in a safe location
for future reference.
•Keep compressor in upright position for 24 hours
before water connections and initial power-on. Failure
to do so will void warranty.
•It is recommended to assemble this product on a
tabletop or bench.
•Fixture must be mounted to a flat finished industry
standard wall surface. The wall surface must have
adequate support to secure the fixture, with the
addition of wall anchors (not included) if required.
•All receptacles must be wired to a GFCI protected
circuit. Fixture must be earth grounded per National
Electric Code (NEC).
•Inspect fixture and all parts for damage.
Package Contents:
Box 1 - 761213 Top Assembly for Bottle Filler
Box 2 - 761212 Cooling System for Water Fountain
Voltage/Hertz 115V/60Hz
*Chilling Capacity 8.0 GPH
Full-Load Amps 1.9 Amps
Rated Watts 185 W
Filter Capacity 4750 or 3000 Gallons
Quick-Fill Rate 1.0 GPM
Water Flow Laminar
Overall Dimensions 181/8"W x 16"D x 3713/16"H
Certification
UL399 and CAN/CSA 22.2 No. 120
ADA Compliant
ANSI/NSF 372
ANSI/NSF 42 and 53 (Filter)
* At 46° - 54° (F) against ambient air temperature of 77° (F)
Stainless
Steel Pan
Water
Filter Not Pictured:
Hardware Bag
Mounting Stencil
Mounting Bracket
(attached to rear)
Cooling System
Rubber Gasket
Mounting Bracket
(attached to rear)
Bottle Filler
Top Assembly

3
User's Manual
Wall Mounted Water Bottle
Refilling Station
Check local codes for plumbing
requirements prior to installation.

CONTENTS
Ref. Qty. Description
1 1
Cooling System
2 1
Lower Cover
3 1
Bottom Mounting Bracket
4 1
Bottle Filler Top Assembly
5 1 Back Plate
6 1 Top Mounting Bracket
7 1 Gasket
8 1 Stainless Steel Pan
9 1 Water Filter
10 1Filter Access Door
H1
4M4 x 8mm Lg. Torx
Pan Head Anti-Theft Screw
H2
1Torx Key
H3
2M6 x 20mm Lg. Phillips
Truss Head Screw
H4
4#4 x 1/2 Lg. Phillips
Pan Head Screw
H5
6M4 x .7x 8mm Lg.
Phillips Flat Head Screw
H6
1Filler Access Door Key
WARNING
Assembly and installation
of equipment should be
performed by 2 people.
1
2
H2
H1
1
2
3
Remove Lower Cover
Using the Anti-Theft Screw Star Key, remove the (4)
screws at the bottom of the Lower Cover. Set Lower
Cover aside and save screws for reinstallation.
Remove mounting bracket
Using a Phillips head screwdriver, remove the
Mount Bracket from the rear of the Cooling
System by removing (1) screw. Discard screw
and set bracket aside.
Discard after removal
Assembly Instructions
4
Wall Mounted Water Bottle Refilling Station
Model 761218

5
Wall Mounted Water Bottle
Refilling Station
Remove top mounting bracket
Using a Phillips head screwdriver, remove the
Top Wall Mount Bracket fastened to the rear of
the Bottle Filler Top Assembly by removing (1)
screw. Discard screw and set bracket aside.
Attach gasket
Attach Gasket to the bottom of the Bottle Filler
Top Assembly as shown.
Attach bottle filler
Flip Bottle Filler Top Assembly right-side-up and carefully
feed connections though the Stainless Steel Pan hole.
Ensure gasket is seated properly and lies flat. Attach
Bottle Filler Top Assembly to the Stainless Steel Pan
using (2) H3 screws.
Remove back plate
Using a Phillips head screwdriver, remove Back Plate
from the rear of the Bottle Filler Top Assembly by
removing (3) screws. Set Back Plate aside and save
screws for reinstallation.
6
Discard after
removal
Assembly Instructions
3 4
56
Note: Ensure gasket is seated properly and
lies flat so there are no gaps.
4
4
5
7H3 4
8
5
7X
Stainless
Steel Pan
Table of contents
Other Global Industrial Water Dispenser manuals
Popular Water Dispenser manuals by other brands

IBC Water
IBC Water AST0715MP-960 Installation & operating instructions

Lancaster Water Treatment
Lancaster Water Treatment X FACTOR LX15 Series Installation, operating and service manual

Elkay
Elkay EMABF8 Series Installation & use manual

Oasis
Oasis Osmosis Home installation manual

Monarch Water
Monarch Water ULTIMATE MINI AQUA HE install guide

Haier
Haier HLM-109B instruction manual