Glunz & Jensen PlateWriter Infuse 10102450-0001 User manual

Pre-installation Guide
PlateWriter Infuse
IMPORTANT!
Please keep this manual with other equipment documentation for future reference.
August 9th, 2021
Edition AA, Part No 10105529
English (en-us) Original version

2General information
General information
About this manual
This manual applies to the PlateWriter Infuse .
This manual is valid for serial nos:
PlateWriter Infuse 10102450 - 0001
10103500 - 0001
The PlateWriter Infuse is manufactured by:
Glunz &Jensen s.r.o.
Kosicka 50
080 01 Presov
Slovakia
Always read the Safety Instruction Manual part No 21741 before installing, servicing, or operating the
equipment.
The manual is published by:
Glunz &Jensen A/S
Selandia Park 1
4100 Ringsted
Denmark
Phone: +45 57 68 81 81
E-mail: gjhq@glunz-jensen.com
Internet: www.glunz-jensen.com
Copyright © August, 2021 by Glunz &Jensen A/S
Pre-installation Guide |PlateWriter Infuse August, 2021

General information 3
Reservations
• This manual was written and illustrated using the best possible information available at the time of
publication.
• Any differences between this manual and the PlateWriter Infuse reflect improvements introduced
after the publication of the manual.
• Changes, technical inaccuracies and typographic errors will be corrected in subsequent editions.
• As a part of our policy of continuous improvement, we reserve the right to alter design and
specifications without further notice.
Notes, Cautions and Warnings!
Notes, cautions, and warnings in this manual are used and categorized as described below:
Symbol Meaning Explanation
NOTE
The operator should observe and/or act according to the information in order to
obtain the best possible function of the PlateWriter Infuse.
CAUTION
The operator must observe and/or act according to the information in order to
avoid any mechanical or electrical damage to the PlateWriter Infuse.
WARNING
The operator must observe and/or act according to the information in order to
avoid any personal injury.
Other manuals
Please refer to the PlateWriter Infuse product page on www.glunz-jensen.com for a complete list of
manuals available for the equipment.
The PlateWriter Infuse
Approvals
• Approvals will appear from the labels attached to the name plate or the frame part of the PlateWriter
Infuse.
Unintended use of the PlateWriter Infuse
Glunz & Jensen A/S does not take any responsibility for any damage or accidents caused by unintended
use of the PlateWriter Infuse:
Intended use of the PlateWriter Infuse
Development of photographic materials as specified in “Technical specifications” in Part 1 in this manual.
• Never install the PlateWriter Infuse in explosive environments.
August, 2021 Pre-installation Guide |PlateWriter Infuse

4General information
• It is the responsibility of the owner and operator(s) of the PlateWriter Infuse that the installation is
made in accordance with local regulations, and by engineers authorized to carry out plumbing and
electrical installations.
• The manufacturer cannot be held responsible for any damage caused by incorrect installation of the
PlateWriter Infuse.
Technical data
• Observe technical data from the PlateWriter Infuse name plate and from the "Technical
Specifications" on page1 in this manual.
Chemicals
It is the responsibility of the owner of the PlateWriter Infuse that data is available concerning possible
health risk from the chemicals used with the PlateWriter Infuse.
"End of lifetime" disposal
The PlateWriter Infuse is designed for easy disassembling. All disposal of parts from the PlateWriter
Infuse must be made according to local regulations with special regards to following parts:
• For recycling purposes significant components are marked with material specification according to
the ISO 11469 standard.
• PVC, tank etc., must be sent to a waste deposit with recycling in view. Alternatively the PVC can be
incinerated at a suitable incinerating plant.
• PCBs and other electric parts must be sent to a suitable waste deposit.
Service assistance
If help is needed to correct any problem with the PlateWriter Infuse, please contact your local supplier.
Pre-installation Guide |PlateWriter Infuse August, 2021

When the crate arrives 5
When the crate arrives
Storing the crates
The crates containing the PlateWriter system will usually arrive some time before the arrival of the Service
Technician. In such a case you should prepare an appropriate place indoors to store the crates.
Crate dimensions and weights
Below are the dimensions and weights of the crates included with the delivery:
L x W x H Weight
PlateWriter system 2140 x 1420 x 1500 mm
(84.3 x 55.9 x 59.1")
343 kg
Checking for damage
When receiving the crates do the following:
• Check if the crates are damaged at the time of delivery.
• Report any damage to the crate(s) to the transport company.
• Take notes of the damage before you unpack the crates. Provide a detailed description and/or take a
photograph of the damage.
August, 2021 Pre-installation Guide |PlateWriter Infuse

6When the crate arrives
Transporting the crates
Handling the crates
The icons on the crates indicate how to handle them during transport and storage:
Lifting the crates
To lift the crates, at least a fork-lift truck or two persons and a hand-powered pallet mover are required.
Available doorway width for transport
If the width of the door(s) through which the crates have to be transported to the installation site are too
narrow, you will have to unpack the crates and transportall parts to the installation site separately.
NOTE: Two or more persons are required for this operation.
Pre-installation Guide |PlateWriter Infuse August, 2021

Site requirements 7
Site requirements
General requirements
Environmental requirements
Provide a heating and ventilating system capable of maintaining room temperature between 20 and 24°C
(68 and 75°F) and relative humidity between 40 and 80%.
For heat emission see “Power consumption” on the page 11.
Cleaning facilities
We recommend that you have easy access to a sink and a water tap with hot water for cleaning purposes.
The minimum recommended size of the sink is 90 x 40 cm (35.4 x 15.8").
August, 2021 Pre-installation Guide |PlateWriter Infuse

8Site requirements
Space requirements
PlateWriter dimensions
Pre-installation Guide |PlateWriter Infuse August, 2021

Site requirements 9
Free space around the PlateWriter
Decide where to place the unit and make sure that the free space around it makes operation and servicing
possible.
Be aware of the following:
•Liquid Dot cartridges need to be replaced on each side of the unit.
• Access to cables is required on the right side of the unit.
• Plates are loaded onto the input table from the rear right of the unit.
• After imaging, the plate is placed onto the finishing unit’ s transport belts from the lower front of the
unit.
• After finishing, the plate is removed from the finishing unit’s exit tray at the lower back of the unit.
The recommended minimum free space around the machine is specified in the illustration below:
August, 2021 Pre-installation Guide |PlateWriter Infuse

10 Site requirements
RIP workstation
Location
The RIP workstation is placed in the bracket under the input table from the imaging unit and need to be
connected using the enclosed USB-cable.
Network connection
If the RIP workstation is going to be connected to a local network (LAN) make sure to provide a network
connection nearby.
Power supply
NOTE: Electrical installation must conform to local rules and regulations.
Main power connection
The PlateWriter system requires three main power connections, one for the PlateWriter itself, one for the
finishing unit, and one for the RIP workstation.
The PlateWriter main power inlet is located at the right side of the equipment and finishing unit main power
inlet is located at the rear side under the equipment (see illustration below).
Pre-installation Guide |PlateWriter Infuse August, 2021

Site requirements 11
Power outlet requirements
If not already present, main power outlets should be installed in the room where the unit will be situated.
Max. distance to the machine 2m (6ft.).
WARNING: The units are Class 1 appliances and must be connected to earthed mains socket
outlets.
WARNING: These units require a short circuit protection device in the building installation as
specified below.
CAUTION: The requirements below are specifications for preparing the installationprotection. It is
important to prepare the fuses/circuit breakers with adequate capacity as specified here.
NOTE: Specification on the unit's name plate is the actual input current and will thus not be
identical to below mentioned.
Unit Supply/fuse
EUR Printer unit Single Phase, 1W+N+PE, 230V, 50 - 60 Hz
Fuse: Max. 16A, type D01, gL/gG, interrupting capacity 50kA
Finishing unit Single Phase, 1W+N+PE, 230V, 50 - 60 Hz
Fuse: Max. 16A, type D01, gL/gG, interrupting capacity 50kA
RIP workstation Single Phase, 1W+N+PE, 230V, 50 - 60 Hz
Fuse: Max. 16A, type D01, gL/gG, interrupting capacity 50kA
USA Printer unit Single Phase, 1W + N + PE, 115V, 50 - 60 Hz
Fuse: Max. 20A, class G or CC branch circuit, interrupting capacity 100kA
Finishing unit Single Phase, 2W + PE, 230V, 50 - 60 Hz
Fuse: Max. 20A, class G or CC branch circuit, interrupting capacity 100kA
RIP workstation Single Phase, 1W + N + PE, 115V, 50 - 60 Hz
Fuse: Max. 20A, class G or CC branch circuit, interrupting capacity 100kA
All Voltage tolerance ± 10%
Power consumption
Mode Imaging unit Finisher and ink dryer
EUR/USA Stand by: approx. 175 BTU/hour approx. 170 BTU/hour
Operation: approx. 175 BTU/hour approx. 7100 BTU/hour
August, 2021 Pre-installation Guide |PlateWriter Infuse

12 Site requirements
Power cables
NOTE: The equipment is delivered with the power cables required for the installation (USA only,
outside USA these must be ordered separately).
If, for some reason, you decide to use cables others than those supplied, make sure that they conform to
the directions given below.
CAUTION: If you are replacing a plug, be aware that the yellow/green conductor may only be
connected to a terminal marked or .
Printer + RIP workstation (USA)
1. Appliance coupler (IEC 60320)
2. Plug type NEMA 5-15P
3. Cable min.3x18AWG, type SJT or harder service
Printer + RIP workstation (Rest of world, upon order only)
1. Appliance coupler (IEC 60320)
2. Plug type may vary
3. Cable min.3x18AWG, type SJT or harder service
Pre-installation Guide |PlateWriter Infuse August, 2021

Site requirements 13
Finishing unit (USA)
1. Appliance coupler 16A (IEC 60320)
2. Plug type NEMA L6-15P, 230V AC, 15A
3. Cable min.3x18AWG, type SJT or harder service
Finishing unit (Rest of world)
NOTE: A connector plug only included with the maintenance kit when the country of installation is
specified upon order.
29759, Cable, maintenance kit, Europe
29760, Cable, maintenance kit, UK
29761, Cable, maintenance kit, Denmark
29762, Cable, maintenance kit, Italy
29763, Cable, maintenance kit, Switzerland
NOTE: When deciding what type of cable to use, take into account the mechanical resistance
(operator may step onto cable).
The conductors in the power supply cable should be of copper.
Provide for additional cable protection, e.g., cable covers, if cable is exposed to heavier transport
such as fork-lift trucks etc.
August, 2021 Pre-installation Guide |PlateWriter Infuse

14 Pre-installation checklist
Pre-installation checklist
Please ask the customer to answer the following questions in order to ensure a trouble-free installation of
the processor:
1. Delivery of the crate and transport to the installation site
- A. Is there a place indoors where the crates box can be stored temporarily?
- B. Is there a hand-powered pallet mover, a fork-lift truck or any other lifting
device available?
- C. Can the crates be transported directly to the installation site? See
minimum width specifications on page ?
- D. Are there other factors (stairs, elevators, obstacles, etc.) which should
be taken into account when transporting the crate or processor?
YES NO
If so, explain:...........................................................................
..............................................................................................
..............................................................................................
- E. Are there any known problems in the building where the PlateWriter will
be installed?
If so, explain:...........................................................................
..............................................................................................
..............................................................................................
2. Power supply & network
- A. Make a note of the present supply specifications:
YES NO
No. of phases .......... Voltage .......... V Fused by .......... Amps
Neutral wire? .......... Earth wire? ..........Frequency .......... Hz
- B. Is there a house electrician available?
- C. Is there a network connection nearby?
3. Ventilation and ink storage
- A. Is air condition/ventilation system capable of maintaining room
temperature between 20 and 24°C (68 and 75°F) and relative humidity
between 40 and 80%?
- B. Is capacity of air condition/ventilation adequate with regard to BTU as
specified on page ?
- C. Is there a proper storage facility for ink cartridges?
YES NO
Pre-installation Guide |PlateWriter Infuse August, 2021