Good Doctors Dr's Finder NEO User manual

User manual
Eng
Apex Locator
New Concept of Apex Locator
Model : AL-DFA20
Be Smart, Be Compact!

01
Contents
3. List of Components 09
4. Parts identification 10
5. Installation 11
6. How to use 14
7. Maintenance 21
8. Trouble Shooting 22
9. Specification 25
10. Accessories 25
11. Warranty 25
12. Warranty card 26
2. Safety Information 03
- Warning and caution
- Notes and reference
- Installation and Connection
- Operation
- Maintenance
1. Introduction 02
- Features
- Description

Introduction1
- Touch color screen
- Smallest size
- Rechargeable battery
- Working length select
Features
02 Be Smart, Be Compact!
Thank you for purchasing the device. The instructions described below have been designed to provide the
necessary information for the successful operation, maintenance and safety for the use of this device.
Description
This unit can be used to detect the apex of root canal.

03
Safety information2
It is important to understand the following information to use this product safely.
Warning and caution
Indicates a potentially hazardous situation which, if not avoided, may result in
serious injury or death.
Indicates a potentially hazardous situation which, if not avoided, may result in
minor/moderate injury or in damage of property.
Caution
Warning
Warning and caution used in this manual are shown below.
Notes and references used in this manual are shown below.
Indicates that potential malfunctions may occur if the description is ignored.
Supplementary information to facilitate better operation.
Reference
Note
Notes and references

Be Smart, Be Compact!
- Keep away from source of ignition to avoid fire or explosion.
- Protect the device from any liquid to avoid electric shock or functional error.
- Place the device on a flat and stable surface. Do not drop device to avoid internal
defect that may cause overheating or fire.
- Do not place the electric cord near a gas burner or sources of heat. Should the cord
catch on fire, replace with the new one to avoid short-circuit.
Warning
- Do not use or leave the unit in areas of high temperature or exposed to direct
sunlight, internal circuit defect may cause overheat or fire.
- Securely connect the dust-free power plug to the outlet.
- Use this device ventilated areas. Overheating may cause fire.
- Do not touch the terminal areas of device with finger or conductive objects, such
as metal wire or safety-pin. It may electric shock or fire.
- Do not use any accessories other then supplied. It may cause fire or device malfunction.
- Make sure the cables, file hook, lip hook, and etc are securely plugged for each
and device. A poor connection can prevent measurement.
Caution
Safety information2
Installation and Connection
04

05
Safety information2
Operation
Warning
- Do not plug the charging cable with wet hands. This may result in an electric shock.
- In case of fluid leak from battery or partial discoloration/deformation of the device,
immediately discontinue use.
- Connect the cord to device when charging.
Wrong directed placing may cause malfunction, explosion, or fire.
- In case of partial discoloration of device, immediately turn off the device and repair it.
- In case battery fluid contacts the eye, immediately flush with copious amount of clean
water and seek medical attention.
- Do not use this product on a person with a pacemaker as it may cause malfunction
of the pacemaker.
- Accurate canal measurement is not always possible depending on the shape and
condition of the tooth as well as a decline in the equipment’s performance.
- Do not use damaged accessories (file hook, probe cord, or etc.).
An accurate measurement can not be made with damaged accessories.
- A rubber dam should be used when performing endodontic treatment.
- Check the device operation before each patient. If the indicators in the display do not
all appear normally, the device may not be able to make an accurate measurement.
In this case, stop using the instrument and have it repaired.
- The measured figure on the display does not correspond to any actual distance and
should only be used as estimates.
- Never connect this device to any device not approved by manufacturer.
- In some case such as a blocked canal, a measurement cannot be made.
- Always check the measurement with an x-ray.
In some cases, an accurate measurement cannot be made because of the canal shape,
unusual cases, or poor performance of the device.

Be Smart, Be Compact!
Safety information2
06
Operation
Warning
- Stop using the instrument immediately if you sense something odd or abnormal
while taking a measurement.
- Do not use the device ultrasonic scaler with the lip hook attached to the patient.
Electric noise from the scaler could interfere with canal measurements.
- Autoclave file hook and lip hook after each patient.
- Avoid damage or use of unnecessary force on the power cord and device.
This may cause an electric shock, fire, or malfunction.
- Should battery fluid contact the skin or clothes, immediately wash it off with copious
amount water to avoid skin damage.
- Turn off the device, when don’t use it.
- Do not use this product for any purpose other than dental use.
- This device is not water prove. Be careful the device from the wet or liquid.
In case of malfunction due to this case, it is not covered by warranty.
- Federal law restricts this device to sale by or on the order of a dentist (for U.S.A.).
- Blocked canals cannot be accurately measured.
- This device must not be connected to or used in combination with any other apparatus
or system. It must be used as an integral component of any other apparatus or system.
Manufacturer will not be responsible for accident, equipment damage, bodily injury or
any other trouble which results from ignoring this caution.
Caution

07
Safety information2
- Illumination devices such as fluorescent lights and the Film viewer which use an
inverter can cause the device to operate erratically.
Do not use the device near devices such as these.
- Electromagnetic wave interference could cause this device to operate in an abnormal,
random and possibly dangerous manner.
Cellular phone, transceivers, remote controls and all other devices which transmit
electromagnetic waves located inside the building should be turned off.
- Do not let the file touch the gums. This will cause the meter to jump toApex.
- If the canal is extremely dry, the meter may not move until it is quite close to the apex.
If the meter does not move, try moistening the canal with oxydol or saline.
- Occasionally the meter will make a sudden and large movement as soon as the file is
inserted into the root canal, but it will return to normal as the file is advanced down
towards the apex.
- The lip hook could cause an adverse reaction if the patient has an allergy to metals.
Ask the patient about this before using the lip hook.
- Take care that medicinal solutions such as formalin cresol or sodium hypochlorite
do not get on the file hook or the lip hook. These could cause an adverse reaction
such as inflammation.
- Always clip the file hook to the upper part of file shaft, near the handle.
The metal and plastic part of the file hook can be damaged if they are attached to the
file’s cutting part or the transition to the cutting part.
- Use files and reamers with plastic handles only.
If the file has a metal handle, electrical leakage will occur when the handle is touched by
fingers and it will prevent an accurate root canal measurement. Even if the file handle is
made of plastic, make sure not to touch the metal part of the file with finger.

Be Smart, Be Compact!
Safety information2
08
Maintenance
- Use only accessories supplied from manufacturer to avoid fluid leak, explosion,
or malfunction.
- Do not disassemble or overhaul the device. Unusual performance may cause injuries,
electric shock, fire, or malfunction.
- Be careful from any liquid when cleaning.
- Do not use solvent (containing orange oil, ethanol or acetone) when clean the device.
- User must be in charge of operation, maintenance and check.
- Do not autoclave the probe cord.
Warning
Caution

09
List of components3
Please check the contents described below when removing the contents from the original packaging.
Main body
Charging cable
Probe cord & extension cord
File hook (x 2 ea) Lip hook (x 3 ea)
User ManualRuler (x 2 ea) Stand
Calibration jig

Be Smart, Be Compact!
Parts identification4
10
Probe jack
& Charging port
Touch screen
Charging cable Calibration jig Stand
Power button
Probe cord
& extension cord
File hook
Lip hook
Ruler
Clip

11
Installation5
1. Connecting the probe cord
Insert the probe cord completely into the probe jack
on the upper side of device carefully.
- Make sure the probe cord plug is securely plugged into the probe jack.
A poor connection can prevent measurement.
- Do not drop anything on or bang the probe cord plug after it has been inserted
into the probe jack.
Note
Insert file hook and lip hook into the probe cord.
It doesn’t matter connect the file hook and lip hook any female connector.
Reference
Probe cord
File hook
Probe cord
Lip hook

Be Smart, Be Compact!
Installation5
12
2. Checking the function
Click power button. The display will appear on screen
with beep sound.
Note The device turn off after 1 minute without use.
Check that the probe cord is properly plugged in the jack.
And check that the file hook and lip hook are properly
connected to the probe cord.
Then Touch metal part of the file hook with the lip hook.
Check that all the meter bars on the display light up.
Check the device operation before each patient.
If the indicators in the display do not all appear normally, the device may not be able to
make an accurate measurement.
In this case, stop using the instrument and have it repaired.
Warning
File hook
Lip hook
2.0
0.5
1.0
0.0
0.0
0.0

3. Working length setting
13
Installation5
Drag the screen on upper side to go setting mode.
Set the working length on the setting mode.
Adjust working length by click + or - icon
0.3
0.3
DRAG
3
DRAG

Be Smart, Be Compact!
How to use6
14
1. Operation display and buttons
The meter reading does not correcspond to any actual distance and should only used
as estimates.
Warning
2.0
0.5
1.0
0.0
0.0
0.0
Battery indicator
- On charging:
- Full charged:
- Need to charge:
* If the battery voltage is too low, the device turns
off with “LOW BATTERY” message.
Sound indicator
W.L.S. point
Measured figure
Meter
W.L.S. indicator
Sound indicator
Battery indicator
W.L.S. point
Measured figure
Meter
W.L.S. indicator W.L.S. indicator
Sound indicator
W.L.S. point
Measured figure
Meter
Battery indicator
Can change the display style by drag left or right.
Reference

15
How to use6
2. Operation
1) Turn the device on.
2) Hook the lip hook in the corner of the patient’s mouth.
3) Clip the file hook to the metal shaft of the file.
①
Press in direction of arrow with the thumb.
②
Clip the file
③
Release thumb.
File hook
①
③
②
Lip hook
2.0
0.5
1.0
0.0
0.0
0.0

Be Smart, Be Compact!
16
4) Determine the working length.
- The beep sound is changed as measured figure.
* The working length will differ somewhat depending
on each individual tooth.
This discrepancy must be judged by the dentist as
he works on the tooth.
How to use6
Make sure to take x-ray to check the results.
The beep sound is changed as measured figure.
Reference
Note
2.0
0.5
1.0
0.0
0.0
0.0
2.0
0.5
1.0
0.0
0.5
0.5
2.0
0.5
1.0
0.0
0.5
0.3

17
How to use6
3. After using the device
1) Turn the device off
2) Disconnect the probe cord and other cords or cables.
Note
- Do not pull directly on the cords when connecting or disconnecting the probe
and file hook.
Always grip the connectors to connect and disconnect cords.
- Do not wrap the probe cord around the body of the main unit.
GOOD
BAD
Connect charging cable (micro USB) to device. And connect the charging cable.
4. Charging
Reference
- Charging time is around 1~1.5 hours.
- Can use the electric power source USB port from or 5V AC adapter.
AC adapter for charging should be 5V. If use other voltage adapter, the device could get
malfunction.
Warning

Be Smart, Be Compact!
18
Click the power button for 2 seconds, then the device will be turn off.
5. Turn off
How to use6
If the device is not working for 1 minutes, the device will be turn off to
save electric power.
Reference
1) Display style
There are 3 display style. Drag by finger to left or right.
6. Functions
2) Sound on/off
Click the sound indicator by finger.
Sound on Sound off
DRAG DRAG
1) W.L.S. setting
2) Calibration
Drag the display from bottom to up as follow image by finger. To back drag the display to up again.
7. Setting mode
0.0
DRAG

19
How to use6
1) Ruler
Included ruler can be use as follow
9. Accessory
Drag the display from up to bottom as follow image by finger. To back drag the display to up again.
Click Min. or Sec.
Then adjust the time
by click +, - icon.
8. Timer mode
Reset Start
0100
Click and hold the + or - icon, then the figure change speed will be increased.
Reference
DRAG
This manual suits for next models
1
Table of contents
Popular Medical Equipment manuals by other brands

Ossur
Ossur REBOUND Instructions for use

Chattanooga
Chattanooga Revolution Wireless Service manual

Optimum Medical
Optimum Medical ugofix leg bag straps Instructions for use

Frontiermedical
Frontiermedical toto user guide

Enthermics
Enthermics EC1540bl Operation and care manual

NeuroTek
NeuroTek Advanced Tac/AudioScan operating instructions