Wiring Diagram
⚠Warning
⚡
COLOR CODES:
GR GREEN
SWITCH (PRESS.)
FIELD SPLICE
FIELD GND
LOW VOLTAGE FIELD
RD RED
GY GRAY
EQUIPMENT GND
INTERNAL TO
PROT. DEVICE
INTEGRATED CONTROL
PLUG CONNECTION
SWITCH (TEMP.)
PU PURPLE
JUNCTION
PK PINK
HI VOLTAGE (115V)
LOW VOLTAGE (24V)
BK BLACK
BL BLUE
WH WHITE
OVERCURRENT
BR BROWN
YL YELLOW
HI VOLTAGE FIELD
OR ORANGE TERMINAL
IGNITER
Maximum Airflow Output
Tonnage Menu
Tonnage
Selection Airflow
1.0 400
1.1 440
1.2 480
1.3 520
1.4 560
1.5 600
1.6 640
1.7 680
1.8 720
1.9 760
2.0 800
2.1 840
2.2 880
2.3 920
2.4 960
2.5 1000
2.6 1040
2.7 1080
2.8 1120
2.9 1160
3.0 1200
3.1 1240
3.2 1280
3.3 1320
3.4 1360
Tonnage
Selection Airflow
3.5 1400
3.6 1440
3.7 1480
3.8 1520
3.9 1560
4.0 1600
4.1 1640
4.2 1680
4.3 1720
4.4 1760
4.5 1800
4.6 1840
4.7 1880
4.8 1920
4.9 1960
5.0 2000
5.1 2040
5.2 2080
5.3 2120
5.4 2160
5.5 2200
5.6 2240
5.7 2280
5.8 2320
5.9 2360
6.0 2400
Menu Navigation and Selection Instructions
Using Phone Application over Bluetooth Network:
1) Connect to the furnace (instructions provided by
phone during the connection Process).
2) Select desired settings menu
3) Select item that requires adjustment and make necessary selection
4) Submit Changes
Using On-Board Push Buttons:
1) Use the Right and Left Buttons to scroll between menus
2) Use the Center Button to select desired menu when menu
code is shown on7-segment displays
3) Use the Left and Right Buttons to scroll through options
within the desired menu
(the display will flash while scrolling through options for
selection)
4) Use the Center Button to select the displayed option
(when selected the display will stop flashing)
5) Use the Center Button to finalize selection and return to
the main menu
Airflow Settings Instructions
1) For non-communicating installations, select the type
of unit installed
in the OdS menu (1AC = single-stage air conditioner,
1HP = single-stage heat pump, 2AC = 2 stage air conditioner,
2HP = 2 stage heat pump) Default = OFF (no outdoor unit).
2) The tonnage menu Must be used to select Cooling/Heat Pump
Airflow (non-communicating installation). Tonnage selection options
and corresponding airflow CFM can be found to the right.
[Airflow = Tonnage Selection x 400] Default selection is 6.0
tons.
3) [Optional] Use the Cooling Trim Menu (CtF) to adjust the
cooling airflow from -10% to +10% (2% increments).
This applies for 2 stage communicating outdoor units and single
or 2 stage non-communicating outdoor units.
4) [Optional] Use the Heating Trim Menu (HtF) to adjust the
heat pump airflow from -10% to +10% (2% increments).
This applies for 2 stage communicating outdoor units and single or 2 stage
non-communicating outdoor units.
5) [Optional] Use the Constant Fan Menu (FSD) to select the
percentage of maximum airflow for continuous fan
6) [Optional] Use the Cooling Airflow Profile Menu (CAP) to
select between 5 cooling airflow profiles. Profile options 1-4 are
listed above (option 5 is adjustable). See installation manual for further
details
0140F02616-A
NOTES:.
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE
USED WHEN SERVICING
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE
FURNACE MUST BE REPLACED,
AT LEAST 105
v
C. USE COPPER CONDUCTORS ONLY.
4.UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM
TO N.E.C. AND LOCAL CODES.
• 3 Ton 60k BTUH = 1,400 CFM
•3 Ton 80k BTUH = 1,650 CFM
• 4 Ton Models = 1,760 CFM
• 5 Ton Models = 2,200 CFM
TO +VDC
TO
MICRO
TO
R
GND (4)
+ VDC (1)
RX (2)
TX (3)
CIRCULATOR
INDOOR
AIR
BLWR
RD
GY
PROPERLY POLARIZED
GND
PROTECTION DEVICE
BURNER COMPARTMENT
POWER SUPPLY WITH
LINE
RD
TO
C
BK
RD
DISCONNECT POWER
FLAME SENSOR
INTEGRATED CONTROL MODULE
POWER BEFORE
BR
OR BL
MVC (8)
M
ECM MTR
HARNESS
NO
24 VAC
AUTO RESET PRIMARY
LIMIT CONTROL
BEFORE SERVICING.
PS1 (2)
3
BK
BK
115 VAC/ 1
BLOWER COMPARTMENT
24
BK
BK
INDUCED
DRAFT
BLOWER
C
115 VAC
INDUCTOR COIL
(ON SOME MODELS)
YL
GND
Ø /60 HZ POWER SUPPLY WITHTO 115VAC/ 1
INTEGRATED CONTROL MODULE
GND
2
WH
HOT
SURFACE
IGNITER
MVH (14)
NEUTRAL
DOOR
SWITCH
LOW FIRE
PRESS.
SWITCH
4
3
2
CHASSIS GROUND
WH
VAC
GND
2 CIRCUIT
CONNECTOR
OVERCURRENT
PSO (7)
C
DISCONNECT
HIGH FIRE
PRESS. SW TICH
INDOOR
AIR
CIRCULATOR
BLWR
Ø /60 HZ
N
BK
MANUAL RESET ROLLOUT
LIMIT CO NTROLS
IND LO
40 VA
TRANSFORMER
AUTO RESET AUXILIARY LIMIT
CONTROLS (TWO ON SOME MODELS)
OR
CIRCULATOR
BLOWER
R
GND
JUNCTION BOX
NEUTRAL
LINE
BK
4
POLARIZED AND
HI
FS
2
DISCONNECT
BR
BL
HIGH FIRE
PRESSURE SWITCH
W
NO
MVL (13)
SERVICING. WIRING
WH
BR
ID BLOWER TWO-STAGE PRESSURE
SWITCH ASSEMBLY
5
GND (5)
BK
IND HI
IGN
PK
HLO (10)
PU
L
WH
MANUAL RESET ROLLOUT LIMIT
CONTROLS
Y
ELECTRONIC
AIR CLEANER
BL
NEUTRAL
1
HLI (1)
WH
AUTO RESET PRIMARY
LIMIT CONTROL
NO
WH
MUST BE PROPERLY
OR
OVERCURRENT PROTECTION DEVICE
GR
GROUNDED.
WARNING:
WH
115
NEUTRAL
JUNCTION BOX
GND
1
AND GROUNDED.
BK
GAS
VALVE
24V THERMOSTAT CONNECTIONS
PU
INDUCTOR COIL
(ON SOME MODELS)
TH (4)
C
C
1
TO UNIT MUST BE
VAC
G
C
TR (11)
GR
HOT SURFACE
IGNITER
FLAME
SENSOR
PS2 (12)
LOW FIRE
PRESSURE
SWITCH
1
INTEGRATED CONTROL MODULE
L
BR
3
WIRING TO UNIT
NO
NEUTRAL
N
WH
40 VA
TRANSFORMER
ID
BLWR
TO
MICRO
WARNING:DISCONNECT
BL
AUTO RESET
AUXILIARY LIMIT
CONTROL (TW O ON
SOME MODELS)
FUSE 3 A
2
24 V
3 A
BL
12
2
4
5 CIRCUIT CONNECTOR
4 CIRCUIT MOTOR
CONNECTOR
4
1
FUSE
15
6
5
LINE
2
RD
2
9
14
3
1
BR
11
EAC
CONTROL
MODULE
8
WH
BL
BL
13
3
5
BR
7
1
3
FS
4
YL
OR
DIAGNOSTIC
LED'S
PK
10
GR
RD
BL
BK
EAC
BR
OR
ROLLOUT SWITCH IN (6)
AUX IN (3)
PU
WH
WH
BK
NEUTRAL
THERMOSTAT
C R1 2
DE
YG W
C
R
HUM
-
PK
PU
BK
RD
WH WH
BR
WH
BL
(WHITE-ROGERS)
HI
M
TWO STAGE
GAS VALVE
C
BLOWER
COMPARTEMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
BK
BK
BK
BL
OR