2
ELECTRICAL CONNECTIONS ................................. 21
WIRING HARNESS .............................................. 21
115 VOLT LINE CONNECTIONS .................................. 21
JUNCTION BOX RELOCATION ..................................... 21
24 VOLT THERMOSTAT WIRING .................................. 22
SINGLE-STA G E HEATING T HERMOSTAT A PPLICATION ................ 23
FOSSIL FUEL A PPLICATIONS ...................................... 23
TWINNING .................................................... 23
115 VOLT LINE CONNECTION OF A CCESSORIES
(HUMIDIFIER AND ELECTRONIC A IR CLEANER) .................. 23
GAS SUPPLY AND PIPING ...................................... 24
HIGH A LTITUDE DERATE ........................................ 24
PROPANE GAS CONVERSION ..................................... 24
GAS PIPING CONNECTIONS ...................................... 25
PROPANE GAS T ANKS AND PIPING ............................... 26
CIRCULATING AIR & FILTERS ................................ 27
DUCT WORK - AIR FLOW ....................................... 27
CHECKING DUCT STATIC ........................................ 27
BOTTOM RETURN A IR OPENING [UPFLOW MODELS] ............... 28
FILTERS - READ THIS SECTION BEFORE INSTALLING
THE RETURN A IR DUCT WORK ............................... 28
UPRIGHT INSTALLATIONS ......................................... 29
HORIZONTAL INSTALLATIONS ..................................... 29
STARTUP PROCEDURE & ADJUSTMENT ..................... 29
DRAIN TRAP PRIMING .......................................... 29
FURNACE OPERATION ........................................... 29
GAS SUPPLY P RESSURE MEASUREMENT ........................... 30
GAS MANIFOLD PRESSURE MEASUREMENT AND A DJUSTMENT ........ 31
GAS INPUT RATE MEASUREMENT (NATURAL GAS ONLY) ........... 32
TEMPERATURE RISE ............................................ 32
CIRCULATOR BLOWER SPEEDS ................................... 33
BLOWER HEAT OFF DELAY TIMINGS ............................. 37
NORMAL SEQUENCE OF OPERATION ........................ 37
POWER UP................................................... 37
HEATING MODE ............................................... 37
COOLING MODE ............................................... 38
FAN ONLY MODE ............................................. 38
OPERATIONAL CHECKS ....................................... 38
SAFETY CIRCUIT DESCRIPTION .............................. 38
INTEGRATED CONTROL MODULE ................................. 38
PRIMARY LIMIT ................................................. 38
AUXILIARY LIMIT ............................................... 38
ROLLOUT LIMIT ............................................... 39
PRESSURE SWITCHES ........................................... 39
FLAME SENSOR ................................................ 39
TROUBLESHOOTING ............................................. 39
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS ................... 39
CHECKING FLAME SENSOR ...................................... 39
LIMIT FAULT CODES ........................................... 39
DIAGNOSTIC CHART ............................................ 40
FAULT RECALL ................................................ 40
RESETTING FROM LOCKOUT ..................................... 41
MAINTENANCE ................................................. 41
ANNUAL INSPECTION ........................................... 41
FILTERS ....................................................... 41
BURNERS ..................................................... 42
INDUCED DRAFT AND CIRCULATOR BLOWERS ...................... 42
CONDENSATE TRAP AND DRAIN SYSTEM (QUALIFIED SERVICER ONLY)42
FLAME SENSOR (QUALIFIED SERVICER ONLY) ..................... 42
FLUE PASSAGES (QUALIFIED SERVICER ONLY) ..................... 43
BEFORE LEAVING AN INSTALLATION ........................ 43
REPAIR AND REPLACEMENT PARTS .......................... 43
TROUBLESHOOTING CHART ................................. 44
WIRING DIAGRAM ............................................. 46
SPECIAL INSTRUCTIONS FOR PRODUCTS
INSTALLED IN THE STATE OF MASSACHUSETTS... 47
S
AFETY
C
ONSIDERATIONS
Adhere to the following warnings and cautions when installing,
adjusting, altering, servicing, or operating the furnace. To
ensure proper installation and operation, thoroughly read this
manual for specifics pertaining to the installation and applica-
tion of this product.
This furnace is manufactured for use with natural gas. It may
be field converted to operate on L.P. gas by using the appro-
priate L.P. conversion kit listed in the PROPANE GAS/HIGH ALTITUDE INSTALLATIONS section of this manual
Install this furnace only in a location and position as specified in LOCATION REQUIREMENTS & CONSIDERATIONS section and
INSTALLATION POSITIONS section of this manual.
Provide adequate combustion and ventilation air to the furnace as specified in COMBUSTION & VENTILATION AIR REQUIRE-
MENTS section of this manual.
G
OODMAN
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
.
I
F
YOU
INSTALL
OR
PERFORM
SERVICE
ON
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
PERSONAL
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
. M
ANY
JURISDICTIONS
REQUIRE
A
LICENSE
TO
INSTALL
OR
SERVICE
HEATING
AND
AIR
CONDITIONING
EQUIPMENT
.
WARNING