19
PERFORMANCE DATA
PERFORMANCETEST
Alldatabaseduponlistedindoordrybulbtem-
perature. .00 inches external static pressure
oncoilofoutdoorsection. Indooraircubicfeet
perminute(CFM)aslistedinthe Performance
DataSheets:
Ifconditionsvary from this, resultswill change
asfollows:
1. As indoor dry bulb temperatures in-
crease, a slight increase will occur in
indoor air temperature drop (Delta T).
Lowandhighsidepressuresandpower
willnot change.
2. As indoor CFM decreases, a slight in-
creasewilloccurinindoortemperature
drop (Delta T). A slight decrease will
occur in low and high side pressures
andpower.
A properly operating unit should be within the
subcoolingvalueshownintheCondensingUnit
Specifications.
Aproperlyoperatingunit should be within plus
orminus3 degrees ofthetypical(DeltaT)value
shown.
Aproperlyoperatingunit should be within plus
or minus 7 PSIG of the HI PR shown.
Aproperlyoperatingunit should be within plus
or minus 3 PSIG of the LO PR shown.
Aproperlyoperatingunit should be within plus
or minus 3 Amps of the typical value shown.
NOTE: Pressures are measured at the liquid
andsuction service valve ports.
HIGH STAGE
Outdoor
Temp. ° F. Total
Btuh Sensible
Btuh Latent
Btuh Total
Watts
75° 39,342 27,300 12,043 2,372
80° 38,874 27,318 11,556 2,453
85° 38,406 27,327 11,078 2,534
90° 37,937 27,429 10,508 2,605
95° 37,469 27,520 9,949 2,677
100° 36,532 27,340 9,192 2,737
105° 35,596 27,135 8,461 2,798
110° 34,284 26,244 8,040 2,850
115° 32,973 25,346 7,627 2,903
95° 34,720 27,245 7,476 2,586
TVAConditions@ 95°ODDB, 75°ID DB, 63°ID WB
DSX180361A* / CA*F4961*6** + TXV / MBE2000**-1**,
Design Subcooling @ AHRI 95°F Conditions, 5-7°F @ the Serv. Vlv. -
High Stage
Outdoor
Temp. ° F. Total
Bt uh Sensible
Btuh Latent
Btuh Total
Watts
75° 51,668 37,197 14,471 3,244
80° 51,053 37,221 13,831 3,349
85° 50,438 37,234 13,203 3,454
90° 49,823 37,373 12,450 3,547
95° 49,208 37,497 11,711 3,640
100° 47,977 37,252 10,725 3,718
105° 46,747 36,972 9,775 3,797
110° 45,025 35,759 9,266 3,865
115° 43,303 34,535 8,768 3,933
95° 45,598 37,122 8,476 2,586
TVAConditions @ 95°ODDB, 75°ID DB, 63°ID WB
DSX180481A* / CA*F4961*6** + TXV / MBE2000**-1**,
Design Subcooling @ AHRI 95°F Conditions, 5- 7°F @ the Serv. Vlv. -
High Stage
Outdoor
Temp. ° F. Total
Btuh Sensible
Btuh Latent
Btuh Total
Watts
75° 62,686 43,209 19,476 4,377
80° 61,939 43,238 18,702 4,520
85° 61,193 43,253 17,940 4,662
90° 60,447 43,414 17,033 4,788
95° 59,701 43,558 16,143 4,915
100° 58,208 43,274 14,934 5,022
105° 56,715 42,948 13,767 5,129
110° 54,626 41,539 13,087 5,221
115° 52,536 40,117 12,420 5,314
95° 55,321 43,122 12,199 4,755
TVAConditions @ 95° OD DB, 75° ID DB, 63° ID WB
DSX180601A* / CA*F4961*6** + TXV / MBE2000**-1**,
Design Subcooling @ AHRI 95°F Conditions, 5-7°F @ the Serv. Vlv. -
High Stage