manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Gooxi
  6. •
  7. Chassis
  8. •
  9. Gooxi RMC4124-670-HSE User manual

Gooxi RMC4124-670-HSE User manual

RMC4124-670-HSE
User Manual
Version 1.0
Shenzhen Gooxi Hengyu Technology Co., Ltd
Content
Manual Structure
Foreword
Chapter 1 Chassis Overview
Chapter 2 Easy Installation Instruction
Chapter 3 Chassis Parameters
Shenzhen Gooxi Hengyu Technology Co., Ltd
Foreword
This manual is about the installation and use information of RMC4124-670-HSE
chassis that provided to professional system integrators and personal computer
technicians. The installation and maintenance should be conducted by experienced
technicians only.
Gooxi RMC4124-670-HSE the fourth generation of server chassis is designed
based on standard 2U server and can be assembled into common computing server,
storage server, Internet bar server, database server, VOD storage server, HPC server,
and so on. The server chassis is different from ordinary desktop chassis that pays
more attention to appearance design, as it focuses on the quality and content. Gooxi
RMC4124-670-HSE server chassis uses imported first-class SGCC galvanized steel,
and possessed with the characteristics of fingerprint resistance, corrosion resistance,
heat resistance, heat transfer and thermal reflectivity, formability as well as
weldability.
In addition, taking into account the higher stability requirements of the server
during usage, Gooxi RMC4124-670-HSE server chassis has excellent heat dispersion.
To be specific, the heat dissipation channel is reasonably designed, which can take
away a large amount of heat in the chassis to ensure the stable operation of the server.
The scalability is an important factor to determine whether the server chassis
design is reasonable. Gooxi RMC4124-670-HSE server chassis has stronger
scalability than ordinary chassis, such as: hard disk expander, peripheral expander,
etc.
Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 1 Chassis Overview
1.1 Chassis Structure
(1)Top cover
(2)2.5-inch hard disk box
(3)Backplane
(4)Rear window
(5)Hard disk module
(6)Fan
(7)3.5-inch hard disk box
(8)Left-side ear
(9)Right-side ear
Shenzhen Gooxi Hengyu Technology Co., Ltd
1.2 Rear Window Construction
①Power site
②I/O washer position
③Expansion slot
1.3 Materials Package
96 pieces of #6-32*5mm countersunk screws are used for fixing hard disks.
10 pieces of active studs with the total height of 8mm are used to install the
motherboard.
16 pieces of #6-32*6mm cross recessed pan head
screws are used for fastening the motherboard and
power supply.
0~23 SAS - label.
One 100 * 120 * 0.045mm PE valve bag.
1.4 Chassis View
Front view:
Shenzhen Gooxi Hengyu Technology Co., Ltd
Rear view:
1.5 Related Indicators of Chassis Panel
Shenzhen Gooxi Hengyu Technology Co., Ltd
The above picture shows the front panel buttons and LED indicators; each button
or indicator light has its own function and status description that are described in the
following table:
LED Status Description
No.
Picture
LED Appearance
Description
1
-
LOGO label (labeling or
customized acrylic label)
②
The green light is on
The device is on
③
Reset
The button is used to restart
the server
④
The green light
flashes
The system is running
normally
⑤
The yellow light is
on
Alarm indication,
including system alarm, fan
alarm, power alarm, etc.; the
specific can be viewed
through IPMI management
software
⑥
The green light is on
Internet access 1 connection
is normal
⑦
The green light is on
Internet access 2 connection
is normal
⑧
USB interface
2*USB2.0 interface
Shenzhen Gooxi Hengyu Technology Co., Ltd
1.6 Introduction to Hard Disk Indicator
1、Act LED
2、FaultLED
3、StatusLED
4、LED description is as follows:
Function
Act LED
Fault LED
Status LED
Hard disk at
site
ON
OFF
OFF
Hard disk
activity
Flash 4Hz/s
OFF
OFF
Hard disk
location
ON
Flash 4Hz/s
OFF
Hard disk
fault
ON
OFF
ON
RAID
reconstruction
ON
OFF
Flash 1Hz/s
1.7 Brief Introduction to Backplane
The standard configuration of Gooxi backplane model is RMC4124-BPE-12G,
and the specific description is as follows:
ActLED
Fault LED
StatusLED
Shenzhen Gooxi Hengyu Technology Co., Ltd
RMC4124-BPE-12G
Correspondin
g site
Interface / jumper /
slot
Correspon
ding site
Interface / jumper / slot
1、2、3、4、5
5 ATX power input
10
PMC PM8044 Expander chip
6、7、8、9
4 Sockets of 4PIN
temperature control fans
11、12、13
SFF-8643 12Gb SAS input
interface
1.8 Introduction to the Output Interface of Backplane Hard Disk
Front-built 24-bit expander backplane order:
Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 2 Easy Installation Instruction
2.1 Introduction to the Disassemble Steps of Gooxi 4124 Chassis Cover
⑴Unscrew the top cover screws
⑵Press the button of chassis back cover
Shenzhen Gooxi Hengyu Technology Co., Ltd
⑶Push the back cover
(4) Pull the back cover
2.2 Introduction to the Installation Steps of Gooxi4124 Chassis Fan Module
⑴Install the hot-swappable fan modules into the chassis, respectively.
(1) Finished completion effect of fan module.
Shenzhen Gooxi Hengyu Technology Co., Ltd
(2) Finished completion effect of the last three fan modules.
Shenzhen Gooxi Hengyu Technology Co., Ltd
2.3 Introduction to the Insert and Plug Steps of Gooxi4124 Chassis Hard Disk
⑴Press the button to pull out the hard disk from the hard disk site.
(2)Install the 3.5-inch hard drive to the hard drive bracket according to screw holes, as
shown in the figure below.
Shenzhen Gooxi Hengyu Technology Co., Ltd
(3) The installed hard disk is shown in the following figure:
(4) Insert hard disk to the chassis, and close the switch. As shown in the following
figure.
Shenzhen Gooxi Hengyu Technology Co., Ltd
2.4 Introduction to the Installation Steps of Gooxi4124 Chassis Power Supply
(1) Place the power supply case to the chassis according to the hole site, as shown in
the figure below.
(2) Fix the power supply bracket, and screw on the screws at the position marked in
the figure below.
Shenzhen Gooxi Hengyu Technology Co., Ltd
(3)Insert the hot-swappable power modules PSU1 and PSU2, respectively
Shenzhen Gooxi Hengyu Technology Co., Ltd
(4)The final installation effect of power supply
2.5 Introduction to the Installation Steps of Motherboard on Gooxi 4124 Chassis
(1) Open the chassis, and place insulation pad according to the correct orientation.
Shenzhen Gooxi Hengyu Technology Co., Ltd
Based on the hole of motherboard screw, motherboard active stud (8mm height) is
installed at the corresponding position on the insulation pad. As shown in the figure
below: Install Gooxi G1DE-4B dual circuit motherboard corresponding to the base
hole site.
(2) After the motherboard active stud (8mm height) is installed, place the motherboard
into the chassis and fasten motherboard screw at the hole site. As shown in the figure
below:
Shenzhen Gooxi Hengyu Technology Co., Ltd
2.6 Introduction to the Installation Steps of Built-in 2.5-inch Hard Drive on
Gooxi4124 Chassis
⑴Install the 2.5-inch hard disk on the bracket.
(2) As shown below: Install two 2.5-inch modules on the inside of the chassis
(3)Completed installation effect
Shenzhen Gooxi Hengyu Technology Co., Ltd
(4) Completed installation effect of two built-in hard disks

This manual suits for next models

1

Other Gooxi Chassis manuals

Gooxi RMC2112-670-HSE User manual

Gooxi

Gooxi RMC2112-670-HSE User manual

Gooxi RMC2108-670-HS User manual

Gooxi

Gooxi RMC2108-670-HS User manual

Gooxi RMC4104-790-HTF User manual

Gooxi

Gooxi RMC4104-790-HTF User manual

Gooxi RMC1104-670-HS User manual

Gooxi

Gooxi RMC1104-670-HS User manual

Gooxi RMC3116-670-HSE User manual

Gooxi

Gooxi RMC3116-670-HSE User manual

Gooxi RMC4136-670-HSE User manual

Gooxi

Gooxi RMC4136-670-HSE User manual

Gooxi RMC2112-670-HSE User manual

Gooxi

Gooxi RMC2112-670-HSE User manual

Popular Chassis manuals by other brands

National Instruments SCXI-1373 installation guide

National Instruments

National Instruments SCXI-1373 installation guide

Transition Networks PointSystem CPSMC0100-200 user guide

Transition Networks

Transition Networks PointSystem CPSMC0100-200 user guide

Supermicro SC835XTQ-R982B User

Supermicro

Supermicro SC835XTQ-R982B User

Advantech PCE-5B06-00A1E Startup manual

Advantech

Advantech PCE-5B06-00A1E Startup manual

Advantech ACP-2020 user manual

Advantech

Advantech ACP-2020 user manual

MSI VAMPIRIC 010X manual

MSI

MSI VAMPIRIC 010X manual

National Instruments PXI 1000B user manual

National Instruments

National Instruments PXI 1000B user manual

Cisco ASA5500-HW - Hardware Accessory Kit Network... Hardware installation guide

Cisco

Cisco ASA5500-HW - Hardware Accessory Kit Network... Hardware installation guide

Advantech HPC-7484 user manual

Advantech

Advantech HPC-7484 user manual

CTC Union FRM220-CH01 user guide

CTC Union

CTC Union FRM220-CH01 user guide

SilverStone HB01 manual

SilverStone

SilverStone HB01 manual

InWin 101 TUF GAMING user manual

InWin

InWin 101 TUF GAMING user manual

Multitech ZDXModemRack EN61000-3-2 Brochure & specs

Multitech

Multitech ZDXModemRack EN61000-3-2 Brochure & specs

InWin 3RAMPD017600 user manual

InWin

InWin 3RAMPD017600 user manual

Wyrestorm MX-1616-PP-POH instruction manual

Wyrestorm

Wyrestorm MX-1616-PP-POH instruction manual

Vex Robotics Pro VersaChassis Mini Assembly instructions

Vex Robotics

Vex Robotics Pro VersaChassis Mini Assembly instructions

Svive LUNA X750 manual

Svive

Svive LUNA X750 manual

Allied Telesis SwitchBlade AT-SB4104-00 Quick install guide

Allied Telesis

Allied Telesis SwitchBlade AT-SB4104-00 Quick install guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.