Shenzhen Gooxi Hengyu Technology Co., Ltd
Content
Manual Structure
Foreword
Chapter 1 Chassis Overview
Chapter 2 Easy Installation Instruction
Chapter 3 Chassis Parameters
Shenzhen Gooxi Hengyu Technology Co., Ltd
Foreword
This manual is about the installation and use information of RMC4236-670-HSE
chassis that provided to professional system integrators and personal computer
technicians. The installation and maintenance should be conducted by experienced
technicians only.
Gooxi RMC4236-670-HSE the fourth generation of server chassis is designed
based on standard 2U server and can be assembled into common computing server,
storage server, Internet bar server, database server, VOD storage server, HPC server,
and so on. The server chassis is different from ordinary desktop chassis that pays
more attention to appearance design, as it focuses on the quality and content. Gooxi
RMC4236-670-HSE server chassis uses imported first-class SGCC galvanized steel,
and possessed with the characteristics of fingerprint resistance, corrosion resistance,
heat resistance, heat transfer and thermal reflectivity, formability as well as
weldability.
In addition, taking into account the higher stability requirements of the server
during usage, Gooxi RMC4236-670-HSE server chassis has excellent heat dispersion.
To be specific, the heat dissipation channel is reasonably designed, which can take
away a large amount of heat in the chassis to ensure the stable operation of the server.
The scalability is an important factor to determine whether the server chassis
design is reasonable. Gooxi RMC4236-670-HSE server chassis has stronger
scalability than ordinary chassis, such as: hard disk expansion, peripheral expansion,
etc.
Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 1 Chassis Overview
1.1 Chassis Structure
(1)Top cover
(2)Rear window
(3)Ventilation wall
(4)Backplane
(5)Hard disk module
(6)Base
(7)Hard disk box
(8)Left-side ear
(9)Right-side ear
Shenzhen Gooxi Hengyu Technology Co., Ltd
1.2 Rear Window Construction
①Power site
②I/O washer position
③Expansion slot
1.3 Materials Package
144 pieces of #6-32*5mm countersunk screws are used for fixing hard disks.
10 pieces of active studs with the total height of 8mm are used to install the
motherboard.
16 pieces of #6-32*6mm cross recessed pan head screws are used for fastening
the motherboard and power supply.
0~35 SAS - label.
One 100 * 120 * 0.045mm PE valve bag.
1.4 Chassis View
Front view:
Rear view:
Shenzhen Gooxi Hengyu Technology Co., Ltd
1.5 Related Indicators of Chassis Panel
The above picture shows the front panel buttons and LED indicators; each button
or indicator light has its own function and status description that are described in the
following table:
LED Status Description
No.
Picture
LED Appearance
Description
1
LOGO blue light is
on
The device is on
Shenzhen Gooxi Hengyu Technology Co., Ltd
②
The green light is on
The device is on
③
Reset
The button is used to restart
the server
④
The green light
flashes
The system is running
normally
⑤
The yellow light is
on
Alarm indication,
including system alarm, fan
alarm, power alarm, etc.; the
specific can be viewed
through IPMI management
software
⑥
The green light is on
Internet access 1 connection
is normal
⑦
The green light is on
Internet access 2 connection
is normal
⑧
USB interface
2*USB2.0 interface
1.6 Introduction to Hard Disk Indicator
1、Act LED
2、FaultLED
3、StatusLED
4、LED description is as follows:
Function
Act LED
Fault LED
Status LED
Hard disk at
site
ON
OFF
OFF
Hard disk
activity
Flash 4Hz/s
OFF
OFF
Hard disk
location
ON
Flash 4Hz/s
OFF
ActLED
Fault LED
StatusLED
Shenzhen Gooxi Hengyu Technology Co., Ltd
Hard disk
fault
ON
OFF
ON
RAID
reconstruction
ON
OFF
Flash 1Hz/s
1.7 Brief Introduction to Backplane
The standard configuration of Gooxi backplane models are RMC4124-BPE-12G
and RMC2112-BPE-12G, and the specific description is as follows:
RMC4124-BPE-12G
Correspondin
g site
Interface / jumper /
slot
Correspon
ding site
Interface / jumper / slot
1、2、3、4、5
5 个 ATX 电源输入
10
PMC PM8044 Expander 芯片
6、7、8、9
4 个 4PIN 温控风扇插座
11、12、13
SFF-8643 12Gb SAS 输入接口
RMC2112-BPE-12G
Correspondi
ng site
Interface / jumper /
slot
Correspon
ding site
Interface / jumper / slot
1、2、3
3 ATX power input
11
PMC PM8043 Expander chip
4、5、6、7
4 Sockets of 4PIN
8、9、10
SFF-8643 12Gb SAS input
Shenzhen Gooxi Hengyu Technology Co., Ltd
temperature control fans
interface
1.8 Introduction to the Output Interface of Backplane Hard Disk
Front-built 24-bit expander backplane order:
Back-built 12-bit expander backplane order:
1.9 机箱内部扩展背板连接示意图
Shenzhen Gooxi Hengyu Technology Co., Ltd
Shenzhen Gooxi Hengyu Technology Co., Ltd
Chapter 2 Easy Installation Instruction
2.1 Introduction to the Disassemble Steps of Gooxi 4136 Chassis Cover
⑴Unscrew the top cover screws
⑵Press the button of chassis back cover
⑶Push the back cover
Shenzhen Gooxi Hengyu Technology Co., Ltd
(4) Pull the back cover
2.2 Introduction to the Installation Steps of Gooxi4136 Chassis Fan Module
⑴Install the shock-proof soft nails into the fan.
⑴ 分别将 4 个 8038 风扇安装在风扇模组支架里。
⑵ 风扇安装完成效果图。
Shenzhen Gooxi Hengyu Technology Co., Ltd
⑶ 分别将两个风扇模组安装在机箱内。
⑷ 风扇模组安装完成效果图。
Shenzhen Gooxi Hengyu Technology Co., Ltd
2.3 Introduction to the Insert and Plug Steps of Gooxi4136 Chassis Hard Disk
⑴Press the button to pull out the hard disk from the hard disk site.
Shenzhen Gooxi Hengyu Technology Co., Ltd
(2)Install the 3.5-inch hard drive to the hard drive bracket according to screw holes, as
shown in the figure below.
(3) The installed hard disk is shown in the following figure:
(4) Insert hard disk to the chassis, and close the switch. As shown in the following
figure.
Shenzhen Gooxi Hengyu Technology Co., Ltd
2.4 Introduction to the Installation Steps of Gooxi4136 Chassis Power Supply
(1) Place the power supply case to the chassis according to the hole site, as shown in
the figure below.
(2) Fix the power supply bracket, and screw on the screws at the position marked in
the figure below.
Shenzhen Gooxi Hengyu Technology Co., Ltd
⑴ 将整个底座(含后窗、电源外壳)推进去机箱内,并固定好螺丝。
Shenzhen Gooxi Hengyu Technology Co., Ltd
⑵ 电源外壳完成安装效果图。
(2) Insert the hot-swappable power modules PSU1 and PSU2, respectively
Shenzhen Gooxi Hengyu Technology Co., Ltd
(4)The final installation effect of power supply
2.5 Introduction to the Installation Steps of Motherboard on Gooxi 4136 Chassis
(1) Open the chassis, and place insulation pad according to the correct orientation.
Based on the hole of motherboard screw, motherboard active stud (8mm height) is
installed at the corresponding position on the insulation pad. As shown in the figure
below: Install Gooxi G1DE-4B dual circuit motherboard corresponding to the base
hole site.

Other manuals for RMC4136-670-HSE

1

Other Gooxi Chassis manuals

Gooxi RMC2112-670-HSE User manual

Gooxi

Gooxi RMC2112-670-HSE User manual

Gooxi RMC4124-670-HSE User manual

Gooxi

Gooxi RMC4124-670-HSE User manual

Gooxi RMC4104-790-HTF User manual

Gooxi

Gooxi RMC4104-790-HTF User manual

Gooxi RMC2112-670-HSE User manual

Gooxi

Gooxi RMC2112-670-HSE User manual

Gooxi RMC3116-670-HSE User manual

Gooxi

Gooxi RMC3116-670-HSE User manual

Gooxi RMC1104-670-HS User manual

Gooxi

Gooxi RMC1104-670-HS User manual

Gooxi RMC2108-670-HS User manual

Gooxi

Gooxi RMC2108-670-HS User manual

Popular Chassis manuals by other brands

TP-Link TL-MC1400 installation guide

TP-Link

TP-Link TL-MC1400 installation guide

Lantronix M-MCR-01 user guide

Lantronix

Lantronix M-MCR-01 user guide

SilverStone RM44 user manual

SilverStone

SilverStone RM44 user manual

HDPlex H3 V3 Series installation guide

HDPlex

HDPlex H3 V3 Series installation guide

Supero SC823i user guide

Supero

Supero SC823i user guide

HP StorageWorks P2000 Replacement instructions

HP

HP StorageWorks P2000 Replacement instructions

Cisco Nexus 3000 series Installing

Cisco

Cisco Nexus 3000 series Installing

Philips TES1.0E LA Service manual

Philips

Philips TES1.0E LA Service manual

Supermicro SC213LTQ user manual

Supermicro

Supermicro SC213LTQ user manual

Forcepoint X10G quick start

Forcepoint

Forcepoint X10G quick start

Advantech AIMB-C300 user manual

Advantech

Advantech AIMB-C300 user manual

Hisense MT5659DUHT Service manual

Hisense

Hisense MT5659DUHT Service manual

IXIA XG12 Assembly guide

IXIA

IXIA XG12 Assembly guide

CommScope Quareo 4000 installation instructions

CommScope

CommScope Quareo 4000 installation instructions

Philips L9.2E AA Service manual

Philips

Philips L9.2E AA Service manual

National Instruments NI PXI-1031 user manual

National Instruments

National Instruments NI PXI-1031 user manual

Supermicro SC826E1-R800LP user manual

Supermicro

Supermicro SC826E1-R800LP user manual

Streacom FC5 evo user guide

Streacom

Streacom FC5 evo user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.