Graco 24Z978 User manual

3A5414A
EN
Instructions
Pulse™HUB
For use with Pulse Fluid Management System Components only.
Not approved for use in explosive atmospheres or hazardous locations. For Indoor use
only.
Part Nos.:
Both devices contain ConnectCore6 i.MX6 WiFi/Bluetooth Radio, IC: 1846A-CCIMX6B.
HUB 24Z978 contains XBee Pro S2C TH Radio, IC: 1846A-PS2CTH.
HUB 25D454 contains XBee S2C TH Radio, IC: 1846A-S2CTH.
Both devices contain FCC ID MCQ-CCIMX6B. This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
•This device may not cause harmful interference.
•This device must accept any interference received, including interference that may cause
undesired operation.
HUB 24Z978 contains FCC ID MCQ-PS2CTH. This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
•This device may not cause harmful interference.
•This device must accept any interference received, including interference that may cause
undesired operation.
HUB 25D454 contains FCC ID MCQ-S2CTH. This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
•This device may not cause harmful interference.
•This device must accept any interference received, including interference that may cause
undesired operation.
I
Part No. Approvals
24Z978
25D454
Important Safety
Instructions
Read all warnings and instructions
in this manual and all related Pulse
manuals. Save all instructions.

Pulse HUB Overview and Component ID
23A5414A
Pulse HUB Overview and Component ID
The Pulse HUB is a self-contained computer with the Pulse Fluid Management Software
preloaded. It also is the Personal Area Network (PAN) host used for RF communication with
other Pulse system components (meters, Pump Air Control [PAC’s], Tank Level Monitors
[TLM’s]). Access to the Pulse Fluid Management system is accomplished by http protocol (web
browser on the Local Area Network [LAN]).
FIG. 1
Item Name Description
A Power Inlet Port Plug end of power adapter into power inlet port (A). The other
end of the power adapter is plugged into 120-240 VAC electrical
outlet.
BUSBPort
USB connection port.
C Ethernet
Connection
Supplies connection to the LAN.
D Power Light Steady, green light. When lit, indicates the unit is receiving
power.
E Micro SD Slot Micro SD card access
FAntenna
External antenna for RF signal transmission
G Pulse Fluid
Management
Software Status
Light
Green, Red, and Orange LED indicated status of the Pulse Fluid
Management Software. See HUB Status Light, page 5.
A
ti32390B
C
E
D
G
F
F

Installation
3A5414A 3
Installation
Locate the Pulse HUB in the main part of the shop, high on a wall or on the ceiling, in a
location that provides an unobstructed line of sight, near the meters, PACs, and/or tank level
monitors.
Always c
omply with all applicable local, state and national fire, electrical and safety
regulations.
Facility Layout
FIG. 2

Installation
43A5414A
Connecting HUB to LAN
(Local Area Network)
There are two options available for connect-
ing the HUB to the LAN: Ethernet Cable (C)
or WiFi.
WiFi Connection
See Setup Your Network Guide included with
the HUB for assistance in connection to the
LAN network.
HUB Installation
During installation zip-ties or screws can be
used to allow relocation of the HUB to
optimize RF communication.
Once RF communication is confirmed, the
HUB can be permanently mounted on the
wall or ceiling.
Secure HUB backplate to wall or ceiling using
backplate mounting holes and (user
supplied) screws (FIG. 4).
FIG. 3
C
FIG. 4

Operation
3A5414A 5
Operation
Once the Pulse HUB is installed, verify that
the power light (D) (FIG. 5) is ON and the HUB
is functioning correctly.
When the green power light (D) is illuminated
it indicates the unit is receiving AC power.
The status of the Pulse Fluid Management
Software is indicated by the HUB Status Light
(G) (FIG. 5). See HUB Status Lights table
below for diagnostic definitions.
HUB Diagnostics (D)
HUB Status Light (G)
NOTE: On system boot the SBC will cycle through the LED status lights to confirm they are
functional.
FIG. 5
D
G
Indicator Diagnostic Definition
No green power
light
Indicates that AC power is not connected. Verify that the power adapter is
securely plugged into the component and the AC power outlet
Verify that the AC power outlet is “live”.
Indicator Diagnostic Definition
Solid Green with Blinking
Orange
HUB is running normally using Ethernet.
Solid Green with Blinking
Red
HUB is running normally using WiFi.
Blinking Green with
Blinking Orange
HUB is launching or updating using Ethernet.
Blinking Green with
Blinking Red
HUB is launching or updating using WiFi.
Solid Red HUB has a critical systems failure.
Solid Red with Blinking
Orange
HUB has a critical systems failure with the device network.
Solid Red with Blinking
Green
HUB has a critical systems failure with the Pulse application.

Software
63A5414A
Software
Main Dashboard
Dispenses: Based on user’s selections, displays as a list of pending, active, completed and
canceled dispenses.
Tanks: Displayed as a percentage, reports the amount of fluid remaining in the tank. The fluid
is measured from the bottom of the tank to the full level.
Reports: The Pulse Fluid Management System generates a variety of reports related to data
it collects while the system is operating. Available Reports include:
•Dispense History
•Volumetric History
•Fluid Usage
•Authorization History
•My Reports
Users: There are four User Authorization Levels available in the Pulse Fluid Management
System.
•Administrator (system owner or IT professional) - An Administrator has full access to
the system. they can perform system updates, change device settings, and add new
devices to the system.
•Advanced (parts room/service managers) - An Advanced user can view all system
information. They can update virtual tanks and edit and create work orders. They can
also authorize dispenses.
•Coordinator (service writers/technicians) - A Coordinator can create and edit work
orders.
•Basic (technicians) - A Basic user has the most restricted access to the system. They
can log in to the system and interact with the work orders queue.
Vehicles: The Vehicles Group identifies the vehicles in a service fleet.
FIG. 6

Software
3A5414A 7
Software Setup
Application Settings: General system settings
•General System Settings: Language, Units of Measurement, PIN size, Inactivity
Duration
•Time Settings
•Business Schedule
•E-mail Settings
•Network Settings
Device Settings: Device configuration and firmware settings
•Fluids
•Tanks
•Level Monitors
•Pump Control
•Locations
•Meters
•Device Network
Notification Settings: Configures alerts to be displayed on software or e-mail.
•Pump Control
•Meter
•Network Events
•Tank
•Level Monitor
System Setup
Refer to the Setup Your Network, Register Your Devices, and Configure Your Software Settings
Quick Start Manuals.
FIG. 7

Software
83A5414A
Frequently Asked Questions
1. Q. What does the meter do if the batteries are removed when you are dispensing?
A. If you are not using work orders, the accumulated dispense amount is saved. When
fresh batteries are installed, the meter powers up. The next time a dispense ends, two
entries are entered in the dispense complete log; the accumulated amount from the first
dispense and the dispense just completed.
If the meter is in work order mode, when batteries are reinstalled the meter returns to an
end dispense screen, the trigger is disengaged, and the dispensed amount is displayed.
The dispense must be ended before another can be started.
2. Q. What does the meter do if a low battery condition occurs during a dispense?
A.The trigger is disengaged and the low battery symbol appears on the meter display. If
the meter is allowed to fall asleep in this low battery mode, an attempt will be made to
end the dispense. If the attempt is not successful, when fresh batteries are installed, the
meter returns to an end dispense screen and an end must occur before another dis-
pense can happen.
If the meter is not using work orders, the accumulated dispense value is saved and
entered into the dispense complete log at the next successful end of a dispense.
3. Q. Unplugging the HUB will cause communication over the device to stop immediately.
How is this communication reestablished?
A. Make sure the power is disconnect for at least 5 to 10 seconds. Reconnect the power
supply and allow 6 to 8 minutes for the system to reboot.
4. Q. Why did my work order disappear from the work order queue?
A. The meter might have received a new profile. After the meter receives a new profile
the work order queue is cleaned out.
5. Q. How do I set up a printer?
A. In the Pulse Fluid Management Software, Enable Automatic Print Reports under the
General section of Application Settings. Then, open the Pulse Utility Application. On the
Settings of the Pulse Utility Application select the printer(s) you would like to send auto-
matic print reports to. Once your printers are selected, navigate back to the home screen
of the Pulse Utility Application and click on Start Service. Dispense information will now
automatically print to the desired locations.

Troubleshooting
3A5414A 9
Troubleshooting
Diagnostic Logs
•Login History
•Configuration Log
•Device Events
•Device Status Report
•System Configuration
•Calibration History
•Firmware Update
Problem Cause Solution
HUB will not communicate
with devices (meters, PAC’s,
and TLMs)
HUB is not powered up Verify HUB is powered up
HUB is out of RF range of
meters or TLMs
Ensure HUB is located
within RF range of meters
and TLMs
Weak or no RF signal Changes/obstructions in RF
pathway (i.e., vehicles,
overhead doors, etc.)
Add Graco Extender to
Pulse system. Order Graco
Part No. 17F885 - US,
17F776 - EU, 17F887 - UK,
17F888 - ANZ.
FIG. 8

Parts
10 3A5414A
Parts
Ref Part No. Description Qty
1 131310 FLASH DRIVE
(not shown)
1
2 17S458 ANTENNA 1
3 17S658 POWER ADAPTER
(not shown)
1
4ENCLOSURE
5 LABEL, serial number 1
6 17E169 CABLE, Ethernet 1
3
6
2
4

Technical Specifications
3A5414A 11
Technical Specifications
Dimensions
Pulse HUB
US Metric
Weight HUB with Power Adapter 1.0 lbs 454 g
Operating Temperature Range -4°F to 158°F -20°C to 70°C
Power Supply
To Power Supply 100 - 240 VAC line voltage
50-60 Hz 0.05A
To HUB 5 Vdc (0.5 amps typ)
RF Frequency Band 2400 - 2483.5 MHz
Maximum RF Transmit Power
Model 24Z978 63 mW (18 dBm)
Model 25D454 6.3 mW (8 dBm)

All written and visual data contained in this document reflects the latest product information available at
the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM3A5414
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2018, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com
March 2018
Graco Extended HUB Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and
workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited
warranty published by Graco, Graco will, for a period of twenty four months from the date of sale, repair or replace any
part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed,
operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or
wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence,
accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or
wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied
by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories,
equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco
distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge
any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the
equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which
charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE.
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees
that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to
person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty
must be brought within two (2) years of the date of sale Graco makes no warranty, and disclaims all implied warranties of
merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components
sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors,
switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with
reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying
equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to
a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal
proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in
English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous
documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou
indirectement, avec les procedures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
This manual suits for next models
1
Table of contents
Other Graco Switch manuals
Popular Switch manuals by other brands

NIVELCO
NIVELCO NIVOSWITCH R-2 Series user manual

Spectrex
Spectrex Incite Fire SharpEye FS-1200 user guide

Transition Networks
Transition Networks SISGM1040-184D-LRT install guide

Lindy
Lindy 43387 user manual

Allied Telesis
Allied Telesis Rapier 16fi Hardware reference

Contemporary Controls
Contemporary Controls CTRLink EIDX MP Series installation guide