Granberg 334 User manual

2020-11-14
User manual Height Adjustable Changing Tables
Products
Daycare changing tables
Changing table 332
Changing table 332 - laundry sink
Changing table 333
Changing table 333 - laundry sink
Changing table 334
Changing table 334 - laundry sink
Changing table 335
Changing table 335 - laundry sink
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

Content
1. Introduction
2. Declaration of Conformity with EU-directives
3. Intended use
4. Technical data
5. Safe use
6. Safety arrangements
7. Load distribution and side forces
8. Actions after use
9. Instructions for recycling
10. Spare parts list
11. Electric system
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

1. Introduction
We are proud to supply you with a electric height-adjustable changing table.
The changing table can be adjusted it to a convenient working height by means of the push-button control.
The changing table must only be used by properly qualified persons.
Being qualified carries the obligation to read and comply with these instructions.
It is most important that you read and understand these instructions before using the changing table. If you have
any questions, please contact your supplier.
This instruction booklet should be made available to the personnel concerned, stored in a safe place, and taken with
the product if it is installed in a new location.
Correct use, operation, inspection and maintenance is essential for safe and efficient work.
2. Declaration of Conformity with EU-directives
This product is CE-marked and is granted to conform to the basic safety and operation requirements, in accordance
with de actual Machinery, EMC- and Low voltage Directives. A separate “CE-Declaration of Conformity” is available
in separate document.
3. Intended use
The changing table is designed for its work surface to be raised and lowered.
The table must be used indoors under normal residential conditions of temperature, humidity and lighting.
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

4. Technical data
332 333 334 335
Installation Freestanding Freestanding Wall-mounted Wall-mounted
Total width 620 / 800 / 1000 /
1200 mm
800 / 1400 mm 800 / 1400 mm 800 / 1400 mm
Total depth 800 mm 800 mm 800 mm: 965 mm
1400 mm: 905 mm
822 mm
Width, mattress 620 mm: 530 mm
800 mm: 710 mm
1000 mm: 910 mm
1200 mm: 1110 mm
800 mm: 710 mm
1400 mm: 750 mm
800 mm: 710 mm
1400 mm: 750 mm
800 mm : 710 mm
1400 mm: 750 mm
Depth, mattress 750 mm 710 mm 710 mm 710 mm
Width, wall frame -- -- 625 mm --
Height, wall frame -- -- 1430 mm --
Border height 55 alt. 200 mm 50 alt. 200 mm 50 alt. 200 mm 50 alt. 200 mm
Height adjustment 730 - 1130 mm 720 - 1120 mm 390 - 1110 mm 670 - 1070 mm
Speed level 30 mm / s. 30 mm / s. 41 mm / s. 30 mm / s.
Safety system -- -- Safety switch
beneath the entire
nursing table
--
Power supply
voltage
230 V 230 V 230 V 230 V
Power consumption 230 W 230 W 230 W 230 W
Max. work cycles
per hr
6666
Operating voltage 24 V DC 24 V DC 24 V DC 24 V DC
Weight 800 mm: 70 kg
1400 mm: 80 kg
800 mm: 70 kg
1400 mm: 80 kg
800 mm: 62 kg
1400 mm: 80 kg
800 mm: 50 kg
1400 mm: 65 kg
Max. Load* 50 kg* 50 kg* 50 kg* 50 kg*
IP-Class IP20 IP20 IPX6 IP20
The noise pressure
is less than
70 db(A) 70 db(A) 70 db(A) 70 db(A)
* Distributed load on the table
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

5. Safe use
The changing table is designed to avoid the risk of injury and accident. However, it is still most important that the
user is thoroughly familiar with the correct manner of installing and operating the table.
The changing table must only be used under the conditions described in "Intended use".
The table must be operated in a manner to avoid the risk of personal injury and material damage.
The table must only be operated by persons who have read and understand these instructions and who are
qualified to use it.
Remember that it is your responsibility as user to ensure that nobody suffers injury.
The changing table and the work area must be in good condition. The changing table must not be used in
case of any damage or fault which affects its operational reliability or safety or if it has been repaired,
modified or adjusted without the permission and approval of an authorised person.
Freestading models: Make sure the changing table is steady and horizontal.
Wall-mounted models: Make sure the wall installation is intact.
The push-button unit must be located so that the operator has a clear view of the changing table the whole
time it is moving.
Press only the push-button for the desired direction of movement.
Do not lower the changing table unless the space below is free from persons and objects.
Only handle loads which are steadily and securely arranged.
Never allow the changing table to come in contact with adjacent objects.
Modifications of the changing table which impact on its operational reliability or safety are not permitted.
Plates and markings must not be removed or obliterated.
Do not overload the changing table.
The changing table must undergo annual inspection in the interests of accident prevention.
Do not operate the changing table in potentially explosive environments.
If the changing table is used in a public environment, particularly one where children may enter the
operating area, the operator shall take adequate steps to prevent persons entering the hazardous area, e.g.
by cordoning off said area.
The changing table surface must be clear during inspection, servicing and repair.
Installation, service and repairs may only be carried out by persons possessing the necessary skills.
Only original parts may be used as replacements, otherwise our warranty commitments may be null and
void.
6. Safety arrangements
Model 334 has a built-in comprehensive safety switch beneath the entire nursing table.
7. Load distribution and side forces
Note that the maximum load refers to a load which is spread and distributed evenly over the changing table surface.
Point loads are not permitted.
Essential requirements for load distribution:
The load must be spread over the entire changing table surface.
Lateral forces are not permitted.
Lateral (sideways) forces can be caused e.g. by pressing against the changing table or the load.
It is very difficult to gauge the strength of laterally acting forces, therefore the greatest care must be exercised at all
times.
Safety measures may be required on or around the changing table. Discuss the appropriate measures with your
supplier or with a safety delegate, occupational health inspector or similar person.
We recommend drawing up a Risk Analysis for the work situation in accordance with the Machinery Directive.
If accessory equipment is installed by the user, Granberg must be contacted for approval of the load conditions.
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

8. Actions after use
The changing table shall after use be left in its current position.
Switch off the main switch and lock it in closed position, if unauthorized use can occur.
9. Instructions for recycling
Before the changing table is redeployed in a new location it must be cleaned, inspected, and undergo a functional
test.
The changing table is made of materials which are suitable for recycling or reuse. Specialised firms collect and
dismantle worn-out machinery and recover reusable parts and materials.
10. Spare parts list
If any part does not seem to be working or is broken, contact your supplier.
Only original parts must be used, otherwise all warranty commitments may be void.
Returning parts:
Contact your supplier before returning parts. Do not return parts which are worn out through normal use or
damaged by accident. Return worn, damaged or unserviceable parts if you believe the fault is covered by Warranty.
In this case return the parts promptly, otherwise you may forfeit your rights under Warranty.
When ordering parts, please quote the changing table serial number and type.
Model 332 / 333 / 335
Control box Push button Mattress
Model 334
Control box Cable hand control Mattress
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se

11. Electric system
1. Power supply 220 V AC
2. Control box
3. Motor
4. Push button
Powered by TCPDF (www.tcpdf.org)
Granberg Interior AB - Box 6112 - 600 06 Norrköping - SWEDEN
Tel: +46-11 19 77 50 - E-mail: [email protected] - Internet: www.granberg.se
Other manuals for 334
3
This manual suits for next models
3
Table of contents
Other Granberg Baby & Toddler Furniture manuals

Granberg
Granberg 343 User manual

Granberg
Granberg 332 User manual

Granberg
Granberg 332 User manual

Granberg
Granberg 334 Installation guide

Granberg
Granberg Changing table 333 User manual

Granberg
Granberg 332 User manual

Granberg
Granberg 334 Installation guide

Granberg
Granberg 335 Installation guide

Granberg
Granberg 334 User manual

Granberg
Granberg 332 Installation guide