Code Error Description & Quick Troubleshoo
E00 No error No a tion needed.
E01 Battery Over--
dis harged
Battery voltage is too low.
DC Load will be turned off until battery re-harges to re overy
voltage
E02 Battery
Over-voltage
Battery voltage has ex eeded ontroller Limit.
Che k battery bank voltage for ompatibility with ontroller.
E04 Load Short
Cir uit DC Load short ir uit.
E05 Load Overload DC Load power draw ex eeds ontroller apability.
Redu e load size or upgrade to a higher load apa ity ontroller.
E06 Overheating Controller ex eeds operating temperature limit.
Ensure the ontroller is pla ed in a well-ventilated ool, dry pla e.
E08 Solar Over
--amperage
Solar array amperage ex eeds ontroller rated input amperage.
De rease the amperage of solar panels onne ted to the ontroller
or upgrade to a higher rated ontroller.
E10 Solar Over-voltage
Solar array voltage ex eeds ontroller rated input voltage.
De rease the voltage of solar panels onne ted to the ontroller.
E13 Solar Reverse
Polarity
Solar array input wires onne ted with reverse polarity.
Dis onne t and re- onne t with orre t wire polarity.
E14 Battery Reverse
Polarity
Battery onne tion wires onne ted with reverse polarity.
Dis onne t and re- onne t with orre t wire polarity.
*Conta t Grape Solar for Live te hni al support on additional troubleshooting.
11. Controller Specification
The variable “n" is adopted as a multiplying fa tor when al ulating parameter
voltages, the rule for “n" is listed as: if battery system voltage is 12V, n=l; 24V, n=2.