6INDIGO — Release Notes
Version 1.2.19
Known Restrictions in Software Version 1.2.19
User Manual and Quick Start Guide
The latest versions of User Manual and Quick Start Guide can be down-
loaded from our web site
http://www.thomsongrassvalley.com/docs/
Area Known Problem ID
Acappella No Tally support
Acappella No Audio support
Acappella The integration of an Acappella router works only if both HD serial inputs are connected
to the router outputs. VGA and DVI inputs cannot be used in parallel.
Acappella To avoid re-synchronizating of the Indigo’s integrated scaler it is strictly recommended to
connect a line or frame synchronizer between router output and Indigo’s HD-SDI input.
Acappella If the router output cannot be synchronized after switching to a non-sync source, the
internal scalers of the Indigo needs to be reset by temporary changing the HiRes input
source, e.g. from HD-SDI to VGA or DVI.
Acappella Transitioning Acappella sources faster than two seconds apart will result in transition
command being skipped.
Keyer In PiP mode if Transform is enabled and picture is rotated then edges becomes jagged. To
make edges more soft go to the Crop/Border menu and add crop softness.
Keyer Border menu of HiRes Keyer is only available when keyer is set to PIP mode and Trans-
form is enabled.
80276
Media Player Preroll is only activated when source is selected on PST bus and auto/cut transition is
executed
79938
Scaler Downscaler doesn‘t work for 75Hz standards
Setup SD-Flattened operation mode:
Hi-Res program and preview outputs shows upscaled SD program (because of the hard-
ware restrictions).
Setup HR-Flattened operation mode:
1. Downscaled Hi-Res program and preview are routed to the AUX1 and AUX2 (because
of the hardware restrictions).
2. If SD sources are selected on program and preview bus then preview shows same
source as program (because of the hardware restrictions).
Setup Audio:
Embedding/deembedding is not implemented for DV.
Setup Video/Output:
If Ext. Lock is enabled and H & V are adjusted with some H & V phases combinations,
transformed PiP or key could be damaged. Adjusting the H & V phases of the external
genlock during set up may cause a transformed key to no longer produce the expected
image. Work around - reboot. After adjusting phases will bring key back to normal state.
74347
USB Because of the many different types offered worldwide sometimes an USB Flash Drive is
not detected. Disconnecting and reconnecting the USB Flash Drive may solve this prob-
lem.
75759