GB5
Night Bag
Instructions for use
Order Codes
Re-O de Code P oduct Desc iption
10330Y GB5 Night Bag - rescription
10331Z GB5 Night Bag – Hospital
Night Stands
It is recommended that you use a night stand or
bedside hanger to support the GB5 in use.
Re-O de Code P oduct Desc iption
10705 Flat ack Hanger
10708S 3 in 1 Metal Night Stand
10700J* Hospital Bed Hanger
* For hospital use only
Latex Free Polybag is
Recyclable
Min/Max
Temperature
Keep Dry
Wash Hands
Single Use Only
GB5IFUV1/2017
Great Bear Healthcare Ltd
1 Lambourne Crescent,
Cardiff Business Park,
Cardiff, CF14 5GF
T+44 (0) 29 2074 7770
mail@ bhl.co.uk
www.greatbearhealthcare.co.uk A UK manufacturer committed to Urolo y.
Products available
Nightingale Home Delivery Service
through
1. Call Freephone 0800 318 559 or 02920 747 770.
2. lease ensure you have your G details to hand.
3. Tell us which products are required and how many.
lease make sure you have
at least two week’s supply in
hand before re-ordering.
• Hand Gels
• Radar Keys
• Wet and Dry Wipes
• Disposable Bags
• Night Stands
• Sponge Bag
That’s all – We will do everything else!
Complimentary Items Available:
Instructions For Use
Emptying
1) Close the Libra Leg Bag tap before
disconnecting the GB5 Night Bag (Diagram 3)
2) To empty the GB5 Night Bag pull the safety
clip(4) in a downwards motion (Diagram 4)
3) To activate the t-tap(7), push the plunger to
one side (Diagram 5) – please note once the
tap has been used, it cannot be used again
Befo e Use
1) Wash Hands
2) Remove GB5 Night Bag from packaging
3) Remove the grey protective cap (1) from the
GB5 inlet connector (2)
Disposal
1) Dispose with normal household waste – do not
ush down the toilet
Cautions
• The GB5 is for single use only and cannot be
reused
• Keep out of the reach of children
Connection
1) Insert the ridged inlet connector (2) into the
soft silicone tube on the outlet tap of your
Libra Leg Bag (Diagram 1). Insert the
connector fully to allow a secure connection
between the GB5 and Libra Leg Bag
2) The GB5 should be positioned on a night stand
using the hanger holes (5) located at the top of
the GB5
3) Ensure the GB5 is positioned on a night stand
at a level below the bladder for optimal
drainage
4) Make sure the inlet tubing (3) isn’t kinked which
can restrict the ow of urine
5) To allow urine drainage from your Libra Leg Bag
to the GB5 Night Bag ensure the tap on the
Libra Leg Bag is in the open position (Diagram
2)
Diag am 1
Key
1 rotective Cap 5 Hanger Holes
2 Ridged Inlet Connector 6 Graduated Scale*
3 Inlet Tube 7 T-Tap
4 Safety Clip
5
1
2
3
6
74
* The graduated scale is an approximation and should not be
used for accurate measurement of urine output
Your GB5 Night Bag
GB5 Night Bag is a 3 litre, non-sterile bag designed
for single use.
To reduce the risk of acquiring a catheter
associated urinary tract infection do not
disconnect your Libra Leg Bag from your
Indwelling Catheter. A Leg Bag should only be
disconnected when a new Libra Leg Bag is
required – normally every 5-7 days.
A GB5 can be connected directly to a sheath.
Diag am 2
Open Tap
Diag am 3
Close Tap Diag am 4 Diag am 5

Other Great Bear Healthcare Medical Equipment manuals

Great Bear Healthcare Libra Leg Bag Series User manual

Great Bear Healthcare

Great Bear Healthcare Libra Leg Bag Series User manual

Great Bear Healthcare Libra User manual

Great Bear Healthcare

Great Bear Healthcare Libra User manual

Popular Medical Equipment manuals by other brands

Nellcor N-200 user guide

Nellcor

Nellcor N-200 user guide

PULOX PO-220B instruction manual

PULOX

PULOX PO-220B instruction manual

Vitalograph Asma-1 Using Guide

Vitalograph

Vitalograph Asma-1 Using Guide

Karl Storz TELECAM SL II instruction manual

Karl Storz

Karl Storz TELECAM SL II instruction manual

Bort Generation Knee support manual

Bort

Bort Generation Knee support manual

CUDA XLS-180 Operator's manual

CUDA

CUDA XLS-180 Operator's manual

Dräger Isolette 8000 plus How to Clean

Dräger

Dräger Isolette 8000 plus How to Clean

Nonin Avant 9700 Operator's manual

Nonin

Nonin Avant 9700 Operator's manual

Anetic Aid QA4 21359 Instructions for use

Anetic Aid

Anetic Aid QA4 21359 Instructions for use

Progetti EPG 6 View Plus user manual

Progetti

Progetti EPG 6 View Plus user manual

SCHÖLLY FIBEROPTIC LED Light Source Instructions for use

SCHÖLLY FIBEROPTIC

SCHÖLLY FIBEROPTIC LED Light Source Instructions for use

Supore ST-1200 Operation manual

Supore

Supore ST-1200 Operation manual

Schiller MAGLIFE LIGHT user manual

Schiller

Schiller MAGLIFE LIGHT user manual

Braun Aesculap Acculan 4 Instructions for use/Technical description

Braun

Braun Aesculap Acculan 4 Instructions for use/Technical description

BD EnCor Enspire Quick reference guide

BD

BD EnCor Enspire Quick reference guide

Devon Cirona F-15 quick start guide

Devon

Devon Cirona F-15 quick start guide

Johnson & Johnson ASP STERRAD NX user guide

Johnson & Johnson

Johnson & Johnson ASP STERRAD NX user guide

LINET Eleganza 1 LE Service manual

LINET

LINET Eleganza 1 LE Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.