15
Technical Information
Service Manual
P button
Press this button,the following temperature can be setted circularly: the setting temperature, indoor ambient temperature and
outdoor
to ,displaying the indoor ambient temperature. is the outdoor ambient temperature. 3s laterit will return to the setti
ng temprature or it
depends on the other received signal within3s.
Note: Outdoor ambient temperatue display range is 0~60°C (32~99°F).
As for the outdoor ambient temperature below 0it displays 0°C(32°F).
arm tips: When operating buttons on the cover, please make sure the cover is closed completely.
1. / button(This function is only available for some models)
scavenging function;LCD displays“ ”.Press the button for the second time to start healthy and scavenging functions simultan
eously;LCD
displays“ ”and “ ” .Press this button for the third time to quit healthy and scavenging functions simultaneously
.Press the button for the
fourth time to start healthy function; LCD display“ ” .Press this button again to repeat the operation above.
NOTE: This function is applicable to partial of models.
12. I FEE
L button
button, every 200ms to send I FEE
L once, after this function started,the remote control will send temperature to the main un it in every 10
minutes.When repress this button, this function will be turned of
f.
13. LIGHT button
Press this button at unit On or Of
f status,Light On and Light Off can be set up.After powered on, Light On is defaulted.
AN button
AN button in COOL or DRY mode,the icon is displayed and the indoor fan will continue operation for 2 minutes in order
to dry the indoor unit even though you have turned of
f the unit.After energization, X-FAN OFF is defaulted.X-FAN is not available in
O,FAN or HEAT mode.
15. QUIET button
Press this button,the Quiet status is under the
Auto Quiet mode (display" " and “Auto”signal ) and Quiet mode(display " " singal) and
Quiet OFF(there is no signal of " " displayed),after powered on,the Quiet OFF is defaulted. Under the Quiet mode (Display
" "signal),
the fan speed is not available.
16. SLEE
P button
●Press this button, can select Sleep 1 ( ), Sleep 2 ( ),Sleep 3 ( ) and cancel the Sleep, circulate bet
ween these, after
●Sleep 1 is Sleep mode 1, in Cool, Dehumidify modes: sleep status after run for one hour
, the main unit setting temperature will increase 1°C,
2 hours,setting temperature increased 2°C, the unit will run at this setting temperature; In Heat mode: sleep status after run
for one hour,
the setting temperature will decrease 1°C, 2 hours, setting temperature will decrease 2°C, then the unit will run at this setti
ng temperature.
●Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of sleep temperature curve
.
In Cool mode:
(1) When setting the initial temperature 16~23°C, after turned on Sleep function, the temperature will be increased 1°C in ever
y hour,after
3°C the temperature will be maintained, after 7hours,the temperature will be decreased 1°C, after that the unit will keep on ru
nning under
this temperature;
(2) When setting the initial temperature 24~27°C, after turned on Sleep function, the temperature will be increased 1°C in ever
y hour,after
2°C the temperature will be maintained, after 7hours,the temperature will be decreased 1°C, after that the unit will keep on ru
nning under
this temperature;
(3) When setting the initial temperature 28~29°C, after turned on Sleep function, the temperature will be increased 1°C in ever
y hour, after
1°C the temperature will be maintained, after 7hours,the temperature will be decreased 1°C, after that the unit will keep on ru
nning under
this temperature;
(4) When setting the initial temperature 30°C, under this temperature setting, after 7hours, the temperature will be decreased
1°C, after
that the unit will keep on running under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16°C, it will run under this setting temperature all along.
(2) Under the initial presetting temperature17~20°C, after Sleep function started up, the temperature will decrease 1°C in ever
y hour, after
1°C decreased, this temperature will be maintained.
(3) Under the initial presetting temperature 21~27°C, after Sleep function started up, the temperature will decrease 1°C in ev
ery hour,after
2°C decreased, this temperature will be maintained.
(4) Under the initial presetting temperature 28~30°C, after Sleep function started up, the temperature will decrease 1°C in ev
ery hour, after
3°C decreased, this temperature will be maintained
●Sleep 3- the sleep curve setting under Sleep mode by DI
Y:
(1) Under Sleep 3 mode, press "T
urbo" button for a long time, remote control enters into user individuation sleep setting status, at this time,
the time of remote control will display "1hour ", the setting temperature "88" will display the corresponding temperature of la
st setting sleep
At this time, 1hour will be automatically increased at the timer postion on the remote control, (that are "2hours" or "3hours" or "8hours "),
Outdoor temperature display is not available for some models. At that time, indoor
unit receives " "signal, while it displays indoor