Clean the Filter
indicator light
Continuous operation on
indicator light
Bucket full light indicates
bucket needs to be emptied
4 hour or 2 hour
delay on/off
indicator lights
High Mid and Low fan
indicator lights
Power On
indicator light
About the controls on the dehumidifier.
Controls
Glows when the bucket is ready to be emptied,
or when the bucket is removed or not replaced
in the proper position.
If the bucket is full or missing for more than three
minutes, an alarm will sound for about 10 seconds
to remind you to empty and replace the bucket.
The Water Level Control Switch shuts off the
dehumidifier when the bucket is full, or when
the bucket is removed or not replaced in the
proper position.
When frost builds up on the evaporator coils,
the compressor will cycle off and the fan will
continue to run until the frost disappears.
In the case of a power outage or interruption,
the unit will automatically re-start, in the settings
last used, after the power is restored.
NOTE:
When the bucket is full or removed, the
controls cannot be set.
Press to turn the dehumidifier on and off.
After 250 hours of operation, the Clean the
Filter
indicator light will glow to remind you to
clean the filter. Remove the filter and clean it.
Press to turn off the
Clean the Filter
light.
See the
Care and Cleaning
section.
The humidity level can be set within a range
of 80% RH (Relative Humidity) to 35% RH
(Relative Humidity) in 5% reduce or at
CO for continuous operation.
NOTE:
If
CO
(Continuous) is selected, the
dehumidifier will operate continuously at
its maximum dehumidification settings if
attached to a hose to drain or until the
bucket is full.
For drier air, press the - pad and set to
a lower percent value (%).
For damper air, press the + pad and set
to a higher percent value (%).
When you first use the dehumidifier, set
the humidity control to 45% or 50%. Allow
at least 24 hours for the dehumidifier to
achieve the humidity level. If you still have
damper air than desired, set the humidity
level to a lower setting or select Continuous
for maximum dehumidification.
Shows the set % humidity level while
setting, then shows the actual (+/– 5%
accuracy) room % humidity level.
Controls the fan speed.
Press to select High or Mid or Low fan
speed.
Set the fan control to High for maximum
moisture removal. When the humidity
has been reduced and quiet operation is
preferred, set the fan control to Mid or Low.
This unit has 3-min lag due to the device
for protecting circuit .In order to prolong
the compressor's working life, the compressor
will not start until the unit has run for 3 minutes.
If unit is turned on and running in timer mode
for 2hr or 4hr,can turn off the unit. When unit
stand by and running in timer mode for 2hr or
4hr can turn on the unit.
ON/OFF Pad
FILTER Pad
Humidity Set Control Pads
Display
FAN SPEED Pad
TIMER Pad
Other Features
Auto Shut Off
Alarm
Bucket Full Light
Power Outage
Auto Defrost
3