Greenlife Abby Fresh AF5000z User manual

AF5000z AIR PURIFIER
Owner’s Manual
v1.01
1-888-601-5886

Contents
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
Product Information . . . . . . . . . . . . . . . . . . . . . . . . 03
How to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 05
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 07
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . 08
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 09
NOTE: Plastic wrap on filter must be
removed before use.
*See page 4 for more information.
1-888-601-5886

Dear Customer,
Thank you for choosing the Abby Fresh™.
Our newly introduced Abby Fresh™ will help you have a cleaner, fresher, and
healthier home!
Your new Air Purifier is meticulously designed with high quality materials
and components that are state-of-the-art.
Please read this owner’s manual carefully to familiarize yourself with the
special features and functions of your air purifier.
Keep this owners manual in a safe place for future reference.
Should you have any further questions or need assistance, call our Support
line at 1-888-601-5886.
Thank you again for choosing Abby Fresh™.
1-888-601-58861

Key Features
• Elegant and cozy, creating a favorable environment
for your bedroom or office.
• Effective air cleaner: excellent air flow rate.
• HEPA filter will allow your room to be free from dust
and odor.
• On/Off Activated Oxygen to combat odors.
• Energy-efficient and safe: brushless motor, 110/220V
low-voltage DC, Max power consumption <20 W.
Cautions
Use only Original power adapter, in case the adapter or wire is damaged, please contact
our Customer Center.
DO NOT touch the plug with wet hands, it may cause electric shock.
Unplug the power cord when you clean the unit.
Disconnect the power supply before replacing the filter, or if the unit is not to be used for
a long time.
If there is damage to the adapter, power wire or the socket, do not use the unit or plug
the unit into socket.
Before connecting the unit with the electric power, please check if the power provided in
accordance with the rated power of the product.
DO NOT put any object inside the unit either in inlet or outlet.
DO NOT block the inlet or the outlet of the unit, for this will prevent the air flow and
reduce the effectiveness of air purification.
The unit must be sent to the repair center authorized by our company for service.
DO NOT repair the product yourself, doing so will invalidate the warranty.
DO NOT run the unit without filter, the entry of dust may cause problems in the
equipment and its components.
DO NOT use the unit in a bathroom, it may cause electric shock.
To protect against electrical hazards. DO NOT immerse the unit in water or other liquids.
Keep the unit away from water, heater, and fire.
1-888-601-5886
2
FEATURES

General Instruction (Fig. 1)
Body
Slip Reduction Feet
1-888-601-58863
PRODUCT INFORMATION

Getting Started
• Turn the Air Purifier upside down after unpacking it.
• Rotate the base cover to take out the filter and follow the guide arrow.
• IMPORTANT: Remove outer plastic wrap from new filter before use.
Replace the filter after removing the packing. Take care to rotate the
base cover in reverse direction.
• Keep the unit on a dry, stable and firm surface in straight, upright position.
• Insert the power adapter of the air purifier to the main power supply.
• Switch on with "BEEP“sound, all indicator lights will flash once, indicating
that the product is powered on.
Components
Rotate to open; then lift out
Remove outer plastic wrap
on filter before use
Base Cover
Composite Filter
Bottom of Air
Purifier
1-888-601-58864
PRODUCT INFORMATION

How to use
Start:
After main power is switched on, press the Power button.
The Air Quality indicator Lamp will light up, the unit will run in speed level 1.
AUTO run mode:
Press the [AUTO] button when the unit is in any mode, it will go into the auto
run mode. In the [AUTO] mode, the auto indicator will glow and the unit
automatically adjusts the air flow depending on the indoor air quality. The
Air Quality indicator lamp will glow to the corresponding level of air quality.
A. Power Button B. Z Mode Button C. Air Flow Speed
Select Button
D. Air Flow Speed
Indicator
G. Timer Switch
Button
E. Auto Mode
Button F. Sleep Mode
Button
H. Filter Reset
Button
I. Timer Display /
Residual Life of
Filter Display
Control Panel
51-888-601-5886
HOW TO USE

Sleep mode:
Press the [SLEEP] button after the start or in the other mode, it will go into
the sleep mode. In this mode the sleep indicator will light and the unit will
run in speed 1.
Manual mode:
Press the [Air Flow Speed Select] button after the start or in any other mode,
it will operate in manual mode. In this mode, the corresponding speed
indicator will light and the unit will run at the selected speed. You can
change the speed by pressing the [Air Flow Speed Select ] button.
Z Mode Button (Activated Oxygen)
Press the [Z Mode] button after the start or in any mode, it will go into the Z
Mode. Z Mode will operate for 60 minutes, after which there will be a 15
minute standby period. After the standby period, the Z Mode can be
restarted by pressing [Z Mode] button as needed.
Timer function:
Press the [TIMER] button after the start or in the other mode, it will go into
the timer mode. In this mode you can set the specific time between
0.5-24hrs to automatically switch off the unit. The set time will be indicated
on the display.
Stop function:
If you want to switch off the unit completely press the [Power] button, the
unit will switch off and all lights will go off.
Filter reset button function:
Press this button when starting up, the button lamp light, and the display
will show the residual life of filter "%". 3 seconds later, it will turn back on.
When the filter needs to be changed, the screen will flash “05”. After
replacing filter, hold this button for 5 seconds to reset.
1-888-601-58866
ExcellentBlue
GoodGreen
AverageYellow
PoorRed
AIR QUALITY INDICATOR
HOW TO USE

Maintenance
Before attempting to perform any maintenance on the unit, disconnect the
power adapter.
Filter
Suggested time of changing filter: at least every 6 months.
It depends on different locations and usage level. For example, changing
time of filter may be shorter in contaminated zones or smoking areas, etc.
Please change the filter if the purification results are not good.
Cleanup routine: biweekly - use soft brush or dry cotton cloth to clean the
filter surface only. Do not use water to wash the filter.
Do not force press or pull, because the filter can be broken or deformed
easily. Please change to new one before using, if it is damaged.
Filter Reset
When the filter needs to be changed, the screen will flash “05”. After
replacing filter, hold the [Filter Reset] button for 5 seconds to reset.
Cylinder inner surface cleaning
Notice
1. Keep surface of the sensor clean, or sensitivity is affected and will fail to
work.
2. Recommended cleaning cycle is less than 1 month for daily use.
3. Clean the sensor with a cotton swab as shown in the picture below.
Do not use detergent or any liquid in the cleaning process.
External surface
Please use dry soft fabric to wipe the
surface, inlets and outlets. Do not use a
chemical cleaning agent.
During long periods of no use
Unplug the unit from socket.
Clean the surface and filter.
Store in a dry and cool place and cover with plastic bag.
1-888-601-58867
MAINTENANCE

Problem
Unit will not operate
Smell
Excessive Noise
No air flow
Ineffectiveness
1. Check if air purifier is properly plugged in
and powered on
2. Screen flashing "05", change filter and
reset filter life. See page 7.
1. Make sure parts are firmly positioned in
place
2. Open the base cover and make sure that
any plastic packaging was removed from
the filter
1. Air purifier being operated in sleep mode
- change the mode
2. The air purifier is malfunctioning - check
power supply if problem still exists,
contact your Customer Service
3. Open the base cover and make sure that
any plastic packaging was removed from
the filter
1. The filter is blocked and no longer is
effective - replace the filter
2. Being used in wrong environment such as
an oversized room
1. Filter is too dirty because it’s not replaced
for a long time - replace the filter
2. Using the air purifier in moist conditions
or water entered the filter - Replace filter
3. Using unclean filter for a long time or
completely blocked filter - Clean the filter,
if problem is not resolved, replace the
filter
4. Burning smell - Stop the air purifier
immediately and turn off the power;
contact our customer service department:
1-888-601-5886
Solution
1-888-601-58868
TROUBLESHOOTING

1-888-601-58869
• Green Life™ warrants their air purifiers to the original consumer purchaser
to be free from defects in materials and workmanship under normal
operation and use for a period of three (3) years from the date of original
purchase. Under the terms of the warranty, Green Life™ will repair or
replace any defective part(s) free of charge.
• This warranty is valid only to the original owner with proof of purchase.
• Product abuse, misuse, modification, alteration, or opening the unit
housing, other than as required for filter replacement or routine
maintenance and cleaning (as described in the owner’s manual), will void
the warranty. Spraying fabric cleaners or deodorizers into the product will
cause damage and void the warranty. Use in a commercial application or
marine environment is not authorized, this product is not intended to be
used where salt spray is present and will void the warranty.
• Should the product fail during the warranty period, you must return the air
purifier in original carton or same size acceptable shipping carton prepaid
shipping via UPS, FedEx, or USPS to the address below. Accompanied by
your name, address, telephone number, proof of purchase date and a
description of the defect.
• Upon inspection, if under warranty Green Life™ will repair or replace with a
new or refurbished unit, or an upgrade to similar or higher grade product.
Shipping paid back to original purchaser by Green Life™ (within the
contiguous United States).
• The warranty does not include unusual wear, damage resulting from
accident or unreasonable use and also does not include replacement
filters or other disposable/consumable parts.
PRODUCT WARRANTY

Model
Adapter Power Supply
Unit Power Supply
CADR
Noise Level
Dimensions
AF5000z
Input-110/220V AC/Output-DC24V
12V DC, 2A
100 m’/hr
Max: 56 dBa Min: <25dBa
8.5”x8.5”x13” (220*220*331 mm)
Abby Fresh™ is a Product of Green Life, LLC
320 South Rock Blvd Suite 210 • Reno NV 89502 • Ph 888.601.5886
Produced and distributed exclusively by:
QUESTIONS?
CALL: 1-888-601-5886
Table of contents
Popular Air Cleaner manuals by other brands

Hanseatic
Hanseatic HAP55055WKC user manual

InovaAir
InovaAir AirClean DE20 Plus user manual

Stadler Form
Stadler Form Roger operating instructions

Panasonic
Panasonic EH3020 - AIR PURIFIER-PHCC operating instructions

Panasonic
Panasonic F-PXL45H operating instructions

Kenmore
Kenmore 1500e Series Use & care guide