GreenWorks 41572 User manual

24V LITHIUM-ION AIR COMPRESSOR
41572
Read all safety rules and instructions carefully before operating this tool.
Owner’s Manual
TOLL-FREE HELPLINE: 1-888-90WORKS (888.909.6757)
www.GreenWorksTools.com
Some Greenworks Lithium-Ion products are
sold with or without battery and charger.

2
CONTENTS
Contents .............................................................................................................................. 2
Product specications.......................................................................................................... 2
General safety rules .........................................................................................................3-8
Know your air compressor ................................................................................................... 9
Assembly instruction.......................................................................................................... 9 -11
Operation.......................................................................................................................12-13
Maintenance............................................................................................................................14
Environmentally safe battery disposal....................................................................................15
Troubleshooting..................................................................................................................16-17
Warranty..................................................................................................................18
Exploded View ......................................................................................................................19
Parts List............................................................................................................................ 2 0
Notes ................................................................................................................................ .21
PRODUCT SPECIFICATIONS
24V LITHIUM-ION AIR COMPRESSOR
Motor..........................................................................................................................................24 V
Running horsepower....................................................................................................................1/3
Tank size....................................................................................................0.5 U.S.GALLONS(1.9L)
Air delivery (SCFM*) @ 40 PSI....................................................................................................1.0
Air delivery (SCFM*) @ 90 PSI....................................................................................................0.6
Cut-in pressure (PSI)....................................................................................................................85
Cut-out pressure (PSI)................................................................................................................115
Pump-up time from empty..............................................................................................60 Seconds
Pump-up cycles per full charge....................................................................................................25
Pump-up time from 85 psi (Cut-in pressure)..................................................................30 Seconds
Noise level @ 20ft (dBA)...............................................................................................................74
Power ...............................................................................................................................240 Watts
Weight with battery ..............................................................................................................9.92 lbs
* For use with 24V 2Ah Greenworks battery only. Model # 29842
* For use with 24V Greenworks charger only, Model # 29862

3
GENERAL SAFETY RULES
WARNING
Do not operate this unit until you read and understand this instruction manual for safety, operation
and maintenance instructions.
IMPORTANT SAFETY INSTRUCTIONS
RISK OF EXPLOSION OR FIRE
WHAT CAN HAPPEN HOW TO PREVENT IT
HAZARD
within the motor and pressure
switch to spark.
come into contact with ammable
vapors, they may ignite, causing
re or explosion.
ventilation openings will cause
serious overheating and could
cause re.
Unattended operation of this
product could result in personal
injury or property damage. To
reduce the risk of re, do not
allow the compressor to operate
unattended.
well ventilated area free of
combustible materials, gasoline, or
solvent vapors.
If spraying ammable materials,
locate compressor at least 20 feet
(6.1 m) away from spray area. An
additional length of air hose may
be required.
Store ammable materials in a
secure location away from
compressor.
Never place objects against or on
top of compressor.
Operate commpressor in an open
area at least 12" (30.5 cm) away
from any wall or obstruction that
would restrict the ow of fresh air
to the ventilation openings.
Operate commpressor in a
clean,dry well ventilated area. Do
not operate unit indoors or in any
conned area.
Always remain in attendance with
the product when it is operating.
Always tum off and unplug unit
when not in use.
1.
2.
3.
4.
1.
2/1
2/1
3/1
3/2
3/3
4/1
4/2

4
GENERAL SAFETY RULES
WHAT CAN HAPPEN
RISK OF BURSTING
HOW TO PREVENT IT
1. 1.
2. 2.
The compressed air directly from
your compressor is not safe for
breathing. The air stream may
contain carbon monoxide, toxic
vapors, or solid particles from the
air tank. Breathing these contami-
nants can cause serious injury or
death.
Exposure to chemicals in dust
created by power sanding, sawing,
grinding, drilling, and other
construction activities may be
harmful.
Air obtained directly from the
compressor should never be used to
supply air for human consumption.
In order to use air produced by this
compressor for breathing, suitable
lters and in-line safety equipment
must be properly installed. In-line
lters and safety equipment used
in conjunction with the compressor
must be capable of treating air
to all applicable local and federal
codes prior to human consumption.
Work in an area with good cross
ventilation. Read and follow the
safety instructions provided on the
label or safety data sheets for the
materials you are spraying. Always
use certied safety equipment:
NIOSH/OSHA respiratory protection
or properly t ting face mask
designed for use with your specic
application.
Air Tank: On February 26,2002,the U.S.Consumer Product Safety Commission
published Release # 02-108 concerning air compressor tank safety:
Air compressor receiver tanks do not have an innite life. Tank life is dependent
upon several factors, some of which include operating conditions, ambient conditions,
proper installations, eld modications, and the level of maintenance.
The exact effect of these factors on air receiver life is difcult to predict.
If proper maintenance procedures are not followed, internal corrosion to the
inner wall of the air receiver tank can cause the air tank to unexpectedly rupture
allowing pressurized air to suddenly and forcefully escape, posing risk of injury
to consumers.

5
GENERAL SAFETY RULES
Attachments & accessories:
Tires:
WHAT CAN HAPPEN HOW TO PREVENT IT
1.
1.
1.
1.
1.
1.
2.
3.
Failure to properly drain condensed
water from air tank, causing rust
and thinning of the steel air tank.
Exceeding the pressure rating of
air tools, spray guns, air operated
accessories, tires, and other
inatables can cause them to
explode or y apart, and could
result in serious injury.
Over ination of tires could result in
serious injury and property damage.
Modications or attempted repairs
to the air tank.
Unauthoriaed modications to
the safety valve or any other
components which control air tank
pressure.
Drain air tank daily or after each
use. If air tank develops a leak,
replace it immediately with a
new air tank or replace the entire
compressor.
Follow the equipment
manufacturers recommendation
and never exceed the maximum
allowable pressure rating of
attachments. Never use compressor
to inate small low pressure objects
such as children’s toys, footballs,
basketballs, etc.
Use a tire pressure gauge to check
the tires pressure before each use
and while inating tires; see the tire
sidewall for the correct tire pressure.
NOTE: Air tanks, compressors and
similar equipment used to inate tires
can ll small tires very rapaidly. Adjust
pressure regulator on air supply to
no more than the rating of the tire
pressure. Add air in small increments
and frequently use the tire gauge to
prevent over ination.
2. Never drill into,weld,or make any
modications to the air tank or its
attachments. Never attempt to
repair a damaged or leaking air
tank. Replace with a new air tank.
3. The air tank is designed to
withstand specic operating
pressures. Never make adjustments
or parts substitutions to alter the
factory set operating pressures.
The following conditions could lead to a weakening of the air tank, and result in
a violent air tank explosion:

6
GENERAL SAFETY RULES
WHAT CAN HAPPEN
RISK FROM FLYING OBJECTS
HOW TO PREVENT IT
1. 1/1
1/2
1/3
The compressed air stream can
cause soft tissue damage to
exposed skin and can propel dirt,
chips, loose particles, and small
objects at high speed, resulting in
property damage or personal injury. Never point any nozzle or sprayer
toward any part of the body or at
other people or animals.
Always turn the compressor off and
bleed pressure from the air
hose and air tank before attempting
maintenance, attaching tools or
accessories.
Always wear certied safety
equipment: ANSI Z87.1 eye
protection (CAN/CSA Z94.3)
with side shields when using the
compressor.
WHAT CAN HAPPEN
RISK OF HOT SURFACES
HOW TO PREVENT IT
1. 1/1
1/2
Touching exposed metal such as
the compressor head, engine head,
engine exhaust or outlet tubes, can
result in serious burns.
Never touch any exposed metal parts
on compressor during or
immediately after operation.
Compressor will remain hot for
several minutes after operation.
Do not reach around protective shrouds
or attempt maintenance
until unit has been allowed to cool.

7
GENERAL SAFETY RULES
WHAT CAN HAPPEN
WHAT CAN HAPPEN
RISK FROM MOVING PARTS
RISK OF UNSAFE OPERATION
HOW TO PREVENT IT
HOW TO PREVENT IT
1.
1.
1/1
1
2
3
4
5
6
7
8
1/2
Moving parts such as the pulley,
ywheel, and belt can cause serious
injury if they come into contact with
you or your clothing.
Unsafe operation of your air
compressor could lead to serious
injury or death to you or others.
2. 2.
Attempting to operate compressor
with damaged or missing parts or
attempting to repair compressor
with protective shrouds removed
can expose you to moving parts
and can result in serious injury.
Any repairs required on this product
should be performed by authorized
service center personnel.
Never operate the compressor with
guards or covers which are damaged
or removed.
Review and understand all insructions
and warnings in this manual.
Become familiar with the operation and
con trols of the air compressor.
Keep operating area clear of all persons,
pets, and obstacles.
Keep children away from the air
compressor at all times.
Do not operate the product when
fatigued or under the inuence of
alcohol or drugs. Stay alert at all times.
Never defeat the safety features of this
prod uct.
Equip area of operation with a re
extinguisher.
Do not operate machine with missing,
broken, or un au tho rized parts.
Keep your hair, clothing,and gloves
away from moving parts. Loose
clthes, jewelry, or long hair can be
caught in moving parts.
1/3 Air vents may cover moving parts
and should be avoided as well.

8
GENERAL SAFETY RULES
WHAT CAN HAPPEN
WHAT CAN HAPPEN
RISK OF FALLING
RISK FROM NOISE
GLOSSARY
ACCESSORIES
SAVE THESE INSTRUCTIONS
FOR FUTURE USE
HOW TO PREVENT IT
HOW TO PREVENT IT
1
1
1
1
A portable compressor can fall
from a table, workbench, or roof
causing damage to the compressor
and could result in serious
injury or death to the operator.
Cut-In Pressure: While the motor
is off, air tank pressure drops as you
continue to use your accessory. When
the tank pressure drops to a certain
low level the motor will restart automatically.
The low pressure at which
the motor automatically restarts is
called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor
is turned on and begins to
run, air pressure in the air tank begins
to build. It builds to a certain high
pressure before the motor automatically
shuts off, protecting your air tank
from pressure higher than its capacity.
The high pressure at which the motor
shuts off is called "cut-out" pressure.
Branch Circuit: Circuit carrying electricity
from electrical panel to outlet.
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute;
a unit of measure of air delivery.
PSI: Pounds per square inch gauge;
a unit of measure pressure.
Code Certication: Products that
bear one or more of the following
marks: UL®*, CUL, ETL®*, CETL, have
been evaluated by OSHA certied
independent safety laboratories and
meet the applicable Standards for
Safety.
*UL® is a registered trademark of
Underwriters Laboratories and ETL®
is a registered trademark of Electrical
Testing Laboratories.
Includes: Recoil Hose, Blow gun, 1/4" Quick connector, Tire chuck, Ination needle
Blow gun adaptor, Tapered nozzle, Plumber's tape
Under some conditions and
duration of use, noise from this
product may contribute to hearing
loss.
Always operate commpressor in a
stable secure position to prevent
accidental movement of the unit.
Never operate compressor on a
roof or other elevated position.
Use additional air hose to reach
high locations.
Always wear certied safety
equipment: ANSI S12.6 (S3.19)
hearing protection.

9
KNOW YOUR AIR COMPRESSOR
The safe use of this product requires an understanding of the information on the tool and in this
operator’s manual as well as a knowledge of the project you are attempting. Before use of this
product, familiarize yourself with all operating features and safety rules. (See Fig. 1)
RECOIL HOSE
CHARGER
24V LITHIUM-ION
BATTERY
AIR TANK PRESSURE
GAUGE
TOOL OUTLET
PRESSURE GAUGE
FEMALE QUICK
CONNECT
OUTLET PRESSURE
REGULATOR KNOB
AUTO ON/OFF SWITCH
AIR TANK
AIR TANK DRAIN VALVE
SAFETY VALVE
TIRE CHUCK
END OF HOSE
OR BLOW GUN
OR QUICK CONNECTOR
BLOW GUN
ADAPTOR
OR TAPERED NOZZLE
INFLATION NEEDLE
Fig. 1

10
ASSEMBLY INSTRUCTION
ATTACHING AIR HOSE TO COMPRESSOR
1, Using your left hand push quick connect towards the body of the compressor.
2, Firmly press t the male quick connect portion on the air hose into the female quick
connect and release female quick connect locking hose in place.
NOTE: When connecting or disconnecting air hose remove air from tank,
ASSEMBLE ACCESSORIES
The unit supplied with an accessory kit, choose the accessory needed.
Assemble Accessory Kit
1. Assemble female tire chuck/blow gun/quick coupler to the end of hose and tighten
securely wiith wrenches.
2, Assemble blow gun adaptor to the blow gun.
3, Assemble ination needle/tapered nozzle to the blow gun adaptor.
End of hose
Tire chuck
or quick connector
Blow gun
adaptor
Tapered nozzle
or blow gun
Fig. 2
RECOIL HOSE
Fig. 3

11
UNPACKING
• This product requires assembly.
WARNING
Do not use this product if any parts on the Packing List are already assembled to your product
when you unpack it. Parts on this list are not assembled to the product by the manufacturer and
require customer installation. Use of a product that may have been improperly assembled could
result in serious personal injury.
• Carefully remove the product and any accessories from the box. Make sure that all items
listed in the packing list are included.
• Inspect the product carefully to make sure no breakage or damage occurred during shipping.
• Do not discard the packing material until you have carefully inspected and satisfactorily
operated the product.
• If any parts are damaged or missing, please call 1-888- 909-6757 for assistance.
PACKING LIST
• Air Compressor
• Battery Pack P/N: 31101828
• Battery Charger P/N: 31101830
• Recoil Hose P/N: 3790175A
• Accessory Kit
ASSEMBLY INSTRUCTION
• Operator’s Manual
WARNING
If any parts are damaged or missing do not operate this product until the parts are replaced.
Failure to heed this warning could result in serious personal injury
WARNING
Do not attempt to modify this product or create accessories not recommended for use with this
product. Any such alteration or modication is misuse and could result in a hazardous condition
leading to possible serious personal injury.
1 Blow gun, P/N:37905110
1 1/4” Quick connector, P/N:3790150-1A
1 Tire chuck, P/N:37904110
1 Ination needle, P/N:37902110
1 Blow gun adaptor, P/N:37911110
1 Tapered nozzle, P/N:37904110
1 Plumber’s tape, P/N:37901110

12
BATTERY
IMPORTANT! The battery pack is not charged when it is purchased. Before using the air
compressor for the rst time, place the battery pack in the battery charger and charge. Make
sure to read all safety precautions, and follow the instructions in the Battery Charger section.
To install (See Figure 2.)
1. Align the tongue (3) of the battery pack with the cavity (4) in the air compressor housing.
2. Grasp the air compressor (2) rmly.
3. Push the battery pack into the handle until the latch locks into place.
4. Do not use force when inserting the battery pack. It should slide into position and “click”.
To remove (See Figure 2.)
1. Press the latch button (1) on the battery pack down and hold.
2. Grasp the air compressor (2) rmly, and pull the battery pack out of the housing.
OPERATION
WARNING
Follow these instructions in order to avoid injury and to reduce the risk of electric shock or re:
• Replace the battery pack or the charger immediately if the battery case or charger cord is damaged.
• Verify that the switch is in the OFF position before inserting or removing the battery pack.
• Verify that the battery pack is removed and the switch is in the OFF position before inspecting, adjusting,
or performing maintenance on any part of the blower.
• Read, understand, and follow the instructions contained in the section entitled Charging Procedure.
NOTE: The battery pack ts into the handle snugly in order to prevent accidental dislodging. It may
require a strong pull to remove it.
Fig. 4
4
1
2
3

13
Fig. 5
STARTUP
1. Before each startup,make sure the power switch is in the OFF position
2. Place air compressor on a at,level surface.
3. Release pressure from the system. Drain moisture from the air tank by slowly opening the
air tank drain valve by turning clockwise.Once all the moisture has drained out, close the
tting securely.
4. Turn the pressure regulator knob fully counterclockwise to close airow from air outlet
port.
5. Attach air hose and accessories.
6. Insert the battery pack to the air compressor securely.
7. Turn the compressor ON by moving the switch to the AUTO/ON position and allow the
tank pressure to build.Once the air pressure reaches the maximum preset pressure(“cut-
out “pressure) it will automatically shut off.
8. Slowly turn the pressure regulator knob clockwise to open airow from air outlet port until
desired output pressure is reached.
WARNING
OPERATION
NOTE: Air tank will not pressurize while drain valve is open.
NOTE: The air compressor will automatically restart once the pressure in the air tank
drops below the minimum preset pressure ( "cut-in" pressure).
Too much air pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories.The regulator outlet pressure must never exceed the
maximum pressure rating.
OPEN
AIR TANK PRESSURE
GAUGE
TOOL OUTLET
PRESSURE GAUGE

14
WARNING
Disconnect air compressor from power source and bleed off all air pressure before attempting
any maintenance or repair.
SHUTDOWN AND STORAGE:
MAINTENANCE
NOTE: NEVER stop the air compressor by pulling the battery pack from the compressor housing
as this may result in damage to the compressor.
1. Turn the switch to the OFF position
2. Pull the battery pack out of the air compressor housing.
3. Turn the pressure regulator knob fully counterclockwise to close airow from air outlet port.
Check the outlet pressure gauge to ensure that it reads 0 PSI.
4. Remove the air hose and any air accessories.
5. Drain moisture from the air tank by slowly opening the air tank drain valve by turning counter
clockwise. Tilt tank to remove all moisture. Once all the moisture has drained out, close the
tting securely.
6. Allow the compressor to cool down.
7. Wipe the air compressor clean and store it in a clean, dry, and non-freezing location.
WHEN PERFORMING ANY MAINTENANCE OR SERVICE:
1. The air compressor must be turned off.
2. Pull the battery pack out of the air compressor housing.
3. Open tank drain to bleed off all air pressure before attempting any maintenance or repair.
4. Allow compressor to fully cool before attempting any maintenance or repair.
Check the air compressor frequently for any visible problems and follow maintenance
procedures each time the compressor is used.
MAINTENANCE CHECKLIST:
Daily:
• Drain accumulated liquid from tank.
• Check for unusual noise and/or vibrations.
• Check that all fasteners are secure.
• Wipe compressor clean.
Monthly:
• Check for air leaks.

15
ENVIRONMENTALLY SAFE BATTERY DISPOSAL
The following toxic and corrosive materials are in the batteries used in this blower
battery pack: Lithium-Ion, a toxic material.
WARNING
WARNING
All toxic materials must be disposed of in a specied manner to prevent contamination of the
environment. Before disposing of damaged or worn out Lithium-Ion battery packs, contact your
local waste disposal agency, or the local Environmental Protection Agency for information and
specic instructions. Take the batteries to a local recycling and/or disposal centre, certied for
lithium-ion disposal.
If the battery pack cracks or breaks, with or without leaks, do not recharge it and do not use. Dis-
pose of it and replace with a new battery pack. DO NOT ATTEMPT TO REPAIR IT!
To avoid injury and risk of re, explosion, or electric shock, and to avoid damage to the environ-
ment:
• Cover the battery's terminals with heavy-duty adhesive tape.
• DO NOT attempt to remove or destroy any of the battery pack components.
• DO NOT attempt to open the battery pack.
• If a leak develops, the released electrolytes are corrosive and toxic. DO NOT get the
solution in the eyes or on skin, and do not swallow it.
• DO NOT place these batteries in your regular household trash.
• DO NOT incinerate.
• DO NOT place them where they will become part of any waste landll or municipal solid
waste stream.
• Take them to a certied recycling or disposal centre.

16
TROUBLESHOOTING
I (on)
continuously
when the
power switch
is in the
position.
PROBLEM POSSIBLE CAUSES SOLUTIONS
The motor
will not run or
start.
The power switch is in the 0 (off)
position. Set the power switch to the I (on) position.
The motor’s thermal overload
protection has tripped.
Turn the air compressor off, unplug the power
cord and wait until the motor has cooled
down.
A fuse has blown or a circuit
breaker has been tripped.
Replace the fuse or reset the circuit breaker.
Verify that the fuse has the proper amperage.
Check for low voltage conditions.
Disconnect any other electrical appliances
from the circuit, or operate the compressor on
a dedicated circuit.
The air tank pressure exceeds the
preset pressure switch limit.
The motor will start automatically when the
tank pressure drops below the cut-in
pressure.
The safety valve is stuck open lean or replace the safety valve.
Electrical connections are loose. technician.
The motor, capacitor or safety
valve is defective. technician.
The motor
runs
The pressure switch does not
shut off the motor when the air
compressor reaches the cut-out
pressure and the safety valve
activates.
Set the power switch to the 0 (off) position.
If the motor does not shut off, unplug the air
compressor. If the pressure switch is defective,
replace it.
The compressor’s capacity is not
enough.
Check the air requirements of the accessory
that is being used. If it is higher than the SCFM
(Standard Cubic Feet per Minute, page 2) and
pressure supplied by the compressor, a larger
capacity air compressor is needed. Most
accessories are rated at 25% of actual SCFM
while running continuously.
Battery not fully installed.
Battery requires charging.
Remove and reinstall the battery
Remove battery and fully charge and battery
charger.
C.

17
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSES SOLUTIONS
The
regulator does
not regulate
the pressure.
The regulator or its internal parts
are dirty or damaged. Replace the regulator.
The pressure
is low, or there
is not enough
air.
There is a leak at one of the
threads). Do not overtighten.
The tank drain valve is open. Close the drain valve.
The air intake is restricted. Clean the ventilation openings on the motor's
enclosure.
Prolonged excessive use of air.D ecrease the amount of air used.
There is a hole in the air hose. Check the air hose and replace it if necessary.
The tank leaks. Replace the tank Immediately. Do not attempt
to repair it.
The valve is leaking. Check for worn parts, and replace them if
necessary.
There is
moisture in the
discharge air.
There is condensation in the air
tank caused by a high level of
atmospheric humidity or because
the air compressor has not been
running long enough.
Drain the air tank after each use. Drain the air
tank more often in humid weather and use an
The
compressor
overheats.
The ventilation is inadequate. Relocate the compressor to an area with cool,
dry and well-circulated air.
Cooling surfaces are dirty. Clean all cooling surfaces on the pump and the
motor thoroughly.
The valve is leaking. Replace worn parts and reassemble using new

18
LIMITED FOUR-YEAR WARRANTY
GREENWORKS™ hereby warranties this product, to the original purchaser with proof of
purchase, for a period of four (4) years against defects in materials, parts or workmanship.
GREENWORKS™, at its own discretion will repair or replace any and all parts found to be
defective, through normal use, free of charge to the customer. This warranty is valid only for
units which have been used for personal use that have not been hired or rented for industrial/
commercial use, and that have been maintained in accordance with the instructions in the
owners’ manual supplied with the product from new.
Battery and charger carries a two (2) year warranty against defects in workmanship and
materials. Batteries must be charged in accordance with the operator’s manuals directions and
regulations in order to be valid.
ITEMS NOT COVERED BY WARRANTY:
1. Any part that has become inoperative due to misuse, commercial use, abuse, neglect,
accident, improper maintenance, or alteration; or
2. The unit, if it has not been operated and/or maintained in accordance with the owner's
manual; or
3. Normal wear, except as noted below;
4. Routine maintenance items such as lubricants, blade sharpening;
5. Normal deterioration of the exterior nish due to use or exposure.
GREENWORKS HELPLINE (1 888 90WORKS):
Warranty service is available by calling our toll-free helpline, at 1-888-909-6757
(1-888-90WORKS).
TRANSPORTATION CHARGES:
Transportation charges for the movement of any power equipment unit or attachment are the
responsibility of the purchaser. It is the purchaser’s responsibility to pay transportation charges
for any part submitted for replacement under this warranty unless such return is requested in
writing by GREENWORKS.

19
EXPLODED VIEW
36
37
38
39
44
40
41
43
42

20
PARTS LIST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
31101828
34106978
3290275
33302755
3290252
3410152
3750150A
34102755
32201113
34901755
32206110
33902755
34202744
33209115
3220252A
31901753
31102755
36302750
32203113
34103755
34108755-1
3290651
3220575
3630150
31905551
3390475
31101755
34207531
34217121
34104744
34110113
3320297-1
34101755
32201744
36201828
31101830
3790175A
37904110
37902110
37911110
37905110
37905110
37903110
37901110
1
1
1
1
1
1
1
1
1
4
10
1
2
1
4
2
1
1
1
1
1
1
1
1
1
2
1
1
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
ITEM NO. PART NO. DESCRIPTION QTY
GW 24V 2Ah Li-Ion Battery (29842)
insert base of housing
drain valve
0.5US gallon tank
bellow spring
rubber cushion
tube connector
right housing
screw ST2.9*15
polyfoam foot
screw 4.2*15-F
aluminum tubeφ6
O ring
Male-threaded quick coupler
screw 6*25
φ40pressure gauge φ40
GW 24V Regulator assy
pressure switch
washer
regulator control panel
regulator knob
Internal-tooth washer
screw M5*10
power switch
safety valve
clamping φ14
Motor pump assy. 24V compressor GW
silicone tube
wire sleeve
rubber pad
inner plastic tube
connector
left housing
screw ST2.9*15
24V PCB board
GW 24V Li-Ion Charger - tool (29862)
Recoil Hose
Tapered nozzle
Ination needle
Blow gun adaptor
Blow gun
1/4” Quick connector
Tire chuck
Plumber’s tape
Table of contents
Other GreenWorks Air Compressor manuals