GRNLITE Par 3-36 User manual

GRN Par 3-36 v5.9
GRNlite.com
Warnings .........................................................................................................1
About the GRN Par 3-36 ..................................................................................2
Power & Data Requirements ...........................................................................3
Fixture Placement, Hanging & Maintenance ...................................................4
Fixture Menu Opons .....................................................................................5
DMX Channel Funcons ..................................................................................6
User Control Panel Illustraon ........................................................................7
Technical Specicaons...................................................................................8
Photometrics..............................................................................................9-11
Menu Tree ....................................................................................................12

GRN Par 3-36 v5.9
GRNlite.com
WARNING: This xture is intended for use by qualied personnel only
Always disconnect xture from AC power before aempng any service.
For use only with electrical power that meets all local and naonal codes.
Fixture must be electrically grounded. Do not aempt to operate this xture without a
proper electrical ground!
This xture is rated IP22 and is for indoor use only.
This xture produces intense opcal radiaon which can damage the rena permanently.
Use extreme cauon when servicing the xture or when in close proximity to the powered
xture. Never look directly into the front of the xture when it is connected to electrical
power!
Do not aempt to modify the xture or add unapproved lenses, ngs, or other electronic
devices.
This xture should not be operated in ambient temperatures above 104ºF (40ºC).
The xture must have a minimum clearance of six inches from the surface of the xture.
Never aempt to wrap the xture with any covering, or aempt any cosmec modicaon
of the xture.
The xture has no user serviceable parts.
Page 1

GRN Par 3-36 v5.9
GRNlite.com
GRN Par 3-36
The GRN Par 3-36 is a high performance LED xture that gives a multude of advantages unique to LED
technology. The RGBW LEDs give a much wider color gamut than tradional RGB systems, in addion to
dramacally increased power eciency over older technology like Quartz lamps. The LED xtures
eliminate the need for dimmers, gels, and large mains power feeds.
Page 2

GRN Par 3-36 v5.9
GRNlite.com
Power Input
The GRN Par 3-36 uses an IEC inlet rated at 10A, 240V as standard. The xture will operate at voltages from
120VAC to 240VAC.
The power cord is a European color code type and should be connected as follows:
NOTE: Only qualied personnel should aempt to change the electrical power connector.
Fuse – 2A, 250V Fuse must be replaced with the proper type and rang.
Data Input
The xture uses standard DMX. The xture uses 3-pin XLRs for DMX data input and thru.
The Data connecons for a 3-pin XLR are as follows:
Pin 1 = GND/Shield
Pin 2 = Data (-)
Pin 3 = Data (+)
Adapng a 5-pin XLR data feed to 3-pin XLR is as follows:
5-pin XLR 3-pin XLR
Pin 1 - Pin 1
Pin 2 - Pin 2
Pin 3 - Pin 3
Pin 4 - N/C
Pin 5 - N/C
Page 3
208V
Brown – Phase 1
Blue – Phase 2
Green/Yellow – Ground
120V
Brown – Hot
Blue – Neutral
Green/Yellow – Ground

GRN Par 3-36 v5.9
GRNlite.com
Fixture placement & hanging
The xture uses a standard yoke for aachments. Half-couplers or Pipe clamps should be used for
hanging the xtures from standard truss. Ground support should be weighted stands or something
similar. The yoke clutch should be loosened (rotate counter clockwise) before aempng to rotate the
xture in the yoke. Rotate the clutch handle clockwise to reghten.
A safety cable should be used for every xture when hung. Fixtures that are used on the ground do
not need a safety.
NOTE: The GRN Par 3-36 xtures may be mounted in any orientaon as long as the aachment
is secure.
Maintenance
There is no standard maintenance required for the GRN Par 3-36 xtures. Even though all
hardware is secured with threadlocker or locking hardware, it is always a good idea to look for any loose
or missing hardware, and ghten or replace as needed. The fricon clutch on the yoke is rugged, but if
forcibly over-rotated, the clutch may be damaged. The fricon clutch should be loosened before
aempng to rotate the xture in the yoke.
NOTE: All repairs of electronic or structural issues should be done by qualied personnel.
Page 4

GRN Par 3-36 v5.9
GRNlite.com
Fixture Menu Opons
NOTE: Be aware that DMX is only acve in “ADDR” mode (when the DMX start address is displayed)
and DMX is not acve in any other mode of operaon or when programming.
Page 5
Mode Funcon Sengs
ADDR Set to any DMX channel between 1 and 507
Node Is actually Mode, used to adjust the 3 LED response modes
-Nad.0 = Instant
-Nad.1 = 300ms Fade me
-Nad.2 = 500ms Fade me
UL Select White proporonal output level only (0 =o, 15=brightest)
BL Select Blue proporonal output level only (0 =o, 15=brightest)
GL Select Green proporonal output level only (0 =o, 15=brightest)
RL Select Red proporonal output level only (0 =o, 15=brightest)
FLAS Strobe Rate (All RGBW LEDs only) (0 =slowest, 15=fastest)
FADE Select preprogrammed Color Fade (0 =slowest, 15=fastest)
CE Select preprogrammed Color Chase (0 =slowest, 15=fastest)
PR Preprogrammed Colors and Looks.
SP Controls speed of PR Programs 14-28
**Control channels 0-13 do not have speed parameters** (0 =slowest, 15=fastest)

GRN Par 3-36 v5.9
GRNlite.com
DMX Channel Funcons
The GRN Par 3-36 uses six DMX channels, and the DMX starng channel for any xture may be set to
any starng address from channel 1 to channel 507 as desired.
Channel Funcon DMX Value
1Dimmer 0-255 Proporonal
2Red 0-255 Proporonal
3Green 0-255 Proporonal
4Blue 0-255 Proporonal
5White 0-255 Proporonal
6Macro/Strobe 0-255 (See Funcon Table Below)
Channel (6) Value Macro Funcon Descripon
0-5No Eect
6-127 Strobe Eect : 6 = Slowest, 127 = Fastest
128-170 Slow Overlapping Color Chase :
R-G-B-RB-RBW-RGBW-RGW-RGBW
171-210
(171=Slow, 210=Fast)
Fading Color Chase :
R-G-B-W-RG-RB-RW-GB-GW-BW-RGB-RBW-BGW-RGW-RGBW
211-255
(211=Slow, 255=Fast)
Color Chase :
R-G-B-W-RG-RB-RW-GB-GW-BW-RGB-RBW-BGW-RGW-RGBW
Page 6

GRN Par 3-36 v5.9
GRNlite.com
GRN Par 3-36
User Controls
Page 7
NOTE: There is a lockout feature that disables the control buons. To enable the control panel, press any
control buon for 3 seconds. The display will ash once when it becomes acve. The control
buons will become inacve again 30-40 seconds aer no buons are pressed.

GRN Par 3-36 v5.9
GRNlite.com
Input Power 90V-240VAC @ 60hz
Power Connector 10A C13 IEC
Operang Current 1.2A @ 208V 60Hz; 1.4A @ 110V 60Hz
Mains Fuse 2A 250V
Weight 8 lbs (3.63 kg)
Dimensions 13” high (including yoke), 10.25” wide (including handles)
Output 6250 Lux @ 1.5 Meters (All colors on full)
Beam Spread 20° Color Mixing Lenses
LED 3 Wa RGBW LEDs:
8-Red, 12-Green, 10-Blue, 6-White
DMX Channels 6 Control Channels:
Intensity, Red, Green, Blue, White, Macro/Strobe
DMX Input / Output 3—Pin XLR in and through