manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Grohe
  6. •
  7. Kitchen & Bath Fixture
  8. •
  9. Grohe Eurostyle 33 995 User manual

Grohe Eurostyle 33 995 User manual

D.....1 I.....5 N.....9 GR .....13 TR .....17 BG .....21 RO .....25
GB .....2 NL .....6 FIN .....10 CZ .....14 SK .....18 EST .....22 CN .....26
F.....3 S.....7 PL .....11 H.....15 SLO .....19 LV .....23 RUS .....27
E.....4 DK .....8 UAE .....12 P.....16 HR .....20 LT .....24
Design & Quality Engineering GROHE Germany
Eurostyle
Eurostyle
96.359.031/ÄM 213919/12.08
33 995
D.....1 I.....5 N.....9 GR .....13 TR .....17 BG .....21 RO .....25
AUS .....1 NL .....6 FIN .....10 CZ .....14 SK .....18 EST .....22 CN .....26
NZ .....1 S.....7 PL .....11 H.....15 SLO .....19 LV .....23 RUS .....27
E.....4 DK .....8 UAE .....12 P.....16 HR .....20 LT .....24
I
Please pass these instructions on to the end user of the fitting.
S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
Bitte diese Anleitung an den Benutzer der Armatur weitergeben!
Please pass these instructions on to the end user of the fitting!
II
1
D
Anwendungsbereich
Betrieb ist möglich mit: Druckspeichern, thermisch und hydraulisch
gesteuerten Durchlauferhitzern. Der Betrieb mit drucklosen Speichern
(offenen Warmwasserbereitern) ist nicht möglich!
Technische Daten:
•Fließdruck: min. 0,5 bar - empfohlen 1 - 5 bar
•Betriebsdruck max. 10 bar
•Prüfdruck 16 bar
Zur Einhaltung der Geräuschwerte ist bei Ruhedrücken über 5 bar ein
Druckminderer einzubauen.
Höhere Druckdifferenzen zwischen Kalt- und Warmwasseranschluss
sind zu vermeiden!
•Durchfluss bei 3 bar Fließdruck: ca. 5 l/min
•Temperatur
Warmwassereingang: max. 80 °C
Empfohlen: (Energieeinsparung) 60 °C
Verbrühschutz möglich durch Einbau eines Temperaturbegrenzers
(siehe Ersatzteile Klappseite II, Best.-Nr.: 46 375)
•Wasseranschluss kalt - rechts
warm - links
Installation
Rohrleitungssystem vor und nach der Installation gründlich spülen!
Einbau und Anschluss, siehe Klappseite III, Abb. [1] und [2].
Maßzeichnung auf Klappseite I beachten.
Kalt-und Warmwasserzufuhr öffnen und Anschlüsse auf Dichtheit
prüfen!
Funktion der Armatur prüfen, siehe Abb. [3].
Mengenbegrenzer
Diese Armatur ist mit einer Mengenbegrenzung ausgestattet. Damit ist
eine stufenlose, individuelle Durchflussmengenbegrenzung möglich.
Werkseitig ist der größtmögliche Durchfluss voreingestellt.
In Verbindung mit hydraulischen Durchlauferhitzern ist der Einsatz
der Durchflussmengenbegrenzung nicht zu empfehlen.
Zur Aktivierung siehe “Austausch der Kartusche” Punkt 1 bis 3, Abb. [4]
und [5].
Wartung
Alle Teile prüfen, reinigen, evtl. austauschen und mit Spezialarmaturen-
fett einfetten.
Kalt- und Warmwasserzufuhr absperren!
I. Austausch der Kartusche, siehe Abb. [4].
1. Stopfen (A) aushebeln.
2. Gewindestift (B) mit Innensechskantschlüssel 3mm herausschrauben
und Hebel (C) abziehen.
3. Kappe (D) abziehen.
4. Verschraubung (E) mit Schlüssel 32mm herausdrehen.
5. Kartusche (F) kpl. austauschen.
Montage in umgekehrter Reihenfolge.
Einbaulage beachten!
Es ist darauf zu achten, dass die Dichtungen der Kartusche und die
Positionszapfen am Boden der Kartusche, in die Eindrehungen bzw.
Bohrungen des Gehäuses eingreifen.
Verschraubung (E) einschrauben und fest anziehen.
II. Reinigung des Mousseurs (13 207), siehe Klappseite II.
Mousseur abschrauben und reinigen.
Ersatzteile, siehe Klappseite II ( * = Sonderzubehör).
Pflege
Die Hinweise zur Pflege dieser Armatur sind der beiliegenden
Pflegeanleitung zu entnehmen.
AUS
Application
Can be used in conjunction with: Pressurised storage heaters, thermally
and hydraulically controlled instantaneous heaters. Operation with low-
pressure displacement water heaters is not possible.
Specifications
•Flow pressure min. 0.5 bar - recommended 1 - 5 bar
•Operating pressure max. 10 bar
•Test pressure 16 bar
If static pressure is greater than 5 bar, fit pressure reducer.
Avoid major pressure differences between hot and cold water
supply.
•Flow rate at 3 bar flow pressure: approx. 5 l/min
•Temperature
Hot water inlet: (maximum) 80 °C
Recommended: (energy saving) 60 °C
Scalding protection possible by fitting a temperature limiter (see
replacement parts fold-out page II, ref. No. 46 375).
•Water connection cold - right
hot - left
Installation
Flush piping system prior and after installation of fitting thoroughly!
Installation and connection, see fold-out page III, Figs. [1] and [2].
Refer to the dimensional drawing on fold-out page I.
Open cold and hot-water supply and check connections for
watertightness!
Check fitting for correct operation, see Fig. [3].
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an infinitely
individual variable reduction in the flow rate. The highest possible flow
rate is set by the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous water heaters is not recommended.
For commissioning see “replacing the cartridge” point 1 to 3,
Figs. [4] and [5].
Maintenance
Inspect and clean all parts, replace as necessary and grease with special
grease.
Shut off cold and hot water supply!
I. Replacing the cartridge, see Fig. [4].
1. Lever out plug (A).
2. Remove set screw (B) using a 3mm socket spanner and pull off
lever (C).
3. Pull off cap (D).
4. Turn out screwing (E) with key 32mm.
5. Change complete cartridge (F).
Assemble in reverse order.
Observe the correct installation position!
Make sure that the cartridge seals engage in the grooves and the
locating pins at the base of the cartridge slot into the apertures on the
housing.
Screw in and tighten screwing (E).
II. Cleaning the aerator (13 207), see fold-out page II.
Unscrew and clean aerator.
Replacement parts, see fold-out page II ( * = special accessories).
Care
For directions on the care of this fitting, please refer to the accompanying
Care Instructions.
NZ
III
13mm
1
24mm
3
A
B
C
D
E
F
32mm
4
3mm
2
5
2,5mm
www.grohe.com
Australia
(National, Queensland)
Argent Australia Pty. Ltd.
ACN - 010 387 809
18 Wandoo Street
Fortitude Valley Queensland 4006
Australia
Tel. 1300 364 748
Fax. 1300 656 057
Australia
(New South Wales)
Argent Sydney
280 Abercombie Street
Chippendale New South Wales 2008
Australia
Tel. (02) 8394 5800
Fax. (02) 8394 5888
Australia
(Victoria, South Australia, Tasmania)
Argent Melbourne
206-208 Coventry Street
South Melbourne Victoria 3205
Australia
Tel. (03) 9682 1231
Fax. (03) 9696 7661
New Zealand
Correspondence:
Paterson Trading Co. Ltd.
P.O. Box 511
Auckland 1
New Zealand
Office:
Corner Boston Road
+ Severn Street
Auckland 1
New Zealand
Tel. 09/373 4324
Fax. 09/377 4739
Singapore
Harpers Trading (S) Pte Ltd
103 Kallang Avenue # 03 - 01/02
AIS Industrial Building
Singapore 339304
Tel. 298 6800
Fax. 298 4188

Other Grohe Kitchen & Bath Fixture manuals

Grohe ATRIO 25 048 User manual

Grohe

Grohe ATRIO 25 048 User manual

Grohe Eurodisc SE 36 233 User manual

Grohe

Grohe Eurodisc SE 36 233 User manual

Grohe Euroeco Special 32 788 User manual

Grohe

Grohe Euroeco Special 32 788 User manual

Grohe Eurosmart 33 202 User manual

Grohe

Grohe Eurosmart 33 202 User manual

Grohe GROHTHERM 1000 NEW 34 573 User manual

Grohe

Grohe GROHTHERM 1000 NEW 34 573 User manual

Grohe Eurosmart Cosmopolitan 19 381 User manual

Grohe

Grohe Eurosmart Cosmopolitan 19 381 User manual

Grohe Ondus 31 053 User manual

Grohe

Grohe Ondus 31 053 User manual

Grohe Atrio 20 008 User manual

Grohe

Grohe Atrio 20 008 User manual

Grohe Eurofresh 19 194 User manual

Grohe

Grohe Eurofresh 19 194 User manual

Grohe MintaTouch User manual

Grohe

Grohe MintaTouch User manual

Grohe BAU COSMO E User manual

Grohe

Grohe BAU COSMO E User manual

Grohe 32 824 User manual

Grohe

Grohe 32 824 User manual

Grohe VITALIO 27 685 User manual

Grohe

Grohe VITALIO 27 685 User manual

Grohe Aquatower 3000 User manual

Grohe

Grohe Aquatower 3000 User manual

Grohe Automatic 2000 19 657 User manual

Grohe

Grohe Automatic 2000 19 657 User manual

Grohe Blue 31 323 User manual

Grohe

Grohe Blue 31 323 User manual

Grohe Ondus 31 047 User manual

Grohe

Grohe Ondus 31 047 User manual

Grohe Chiara 32 303 User manual

Grohe

Grohe Chiara 32 303 User manual

Grohe BauLoop 29 062 User manual

Grohe

Grohe BauLoop 29 062 User manual

Grohe 40 686 User manual

Grohe

Grohe 40 686 User manual

Grohe Minta 32 917 User manual

Grohe

Grohe Minta 32 917 User manual

Grohe Ondus 31 049 User manual

Grohe

Grohe Ondus 31 049 User manual

Grohe Tectro User manual

Grohe

Grohe Tectro User manual

Grohe Eurosmart Cosmopolitan 30 193 User manual

Grohe

Grohe Eurosmart Cosmopolitan 30 193 User manual

Popular Kitchen & Bath Fixture manuals by other brands

Sanela SLU 92B Instructions for use

Sanela

Sanela SLU 92B Instructions for use

FRANZ VIEGENER Nerea Installation

FRANZ VIEGENER

FRANZ VIEGENER Nerea Installation

IKEA LANGSKAR manual

IKEA

IKEA LANGSKAR manual

Nobili Hera 2005 Using instructions

Nobili

Nobili Hera 2005 Using instructions

Peerless Faucet P88LF-L quick start guide

Peerless Faucet

Peerless Faucet P88LF-L quick start guide

Delta Touch2O 1914T Series manual

Delta

Delta Touch2O 1914T Series manual

Glacier bay F51A0074CP Installation and care guide

Glacier bay

Glacier bay F51A0074CP Installation and care guide

Miomare 296071 Assembly, operating and safety instructions

Miomare

Miomare 296071 Assembly, operating and safety instructions

Franke F5 Series Installation and operating instructions

Franke

Franke F5 Series Installation and operating instructions

PEERLESS PTT14023 Series manual

PEERLESS

PEERLESS PTT14023 Series manual

Belanger Essential Style SVE78CMBG installation instructions

Belanger

Belanger Essential Style SVE78CMBG installation instructions

JADO New Classic 888/003 Series installation instructions

JADO

JADO New Classic 888/003 Series installation instructions

Kalia BF1800 installation instructions

Kalia

Kalia BF1800 installation instructions

Axor Citterio M 34448 1 Series Installation/User Instructions/Warranty

Axor

Axor Citterio M 34448 1 Series Installation/User Instructions/Warranty

Sanela SLU 08B Instructions for use

Sanela

Sanela SLU 08B Instructions for use

baliv KI-1060 N 415760 instruction manual

baliv

baliv KI-1060 N 415760 instruction manual

Spectrum Brands Pfister Saxton LG89-XGL Maintenance & Care Guide

Spectrum Brands

Spectrum Brands Pfister Saxton LG89-XGL Maintenance & Care Guide

Symmons Canterbury 45-458-TRM Operation and maintenance manual

Symmons

Symmons Canterbury 45-458-TRM Operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.