Grundig MDI231 User manual

USER MANUAL
BENUTZERHANDBUCH
MANUEL DE L’UTILISATEUR
GEBRUIKSAANWIJZING
MANUAL DE INSTRUCCIONES
MANUALE DELL’UTENTE
0123
Model:MDI231
Item no.: 871125224865
EN:3-in-1 Ear and Forehead infrared thermometer
DE: 3-in-1 Ohr- und Stirn-Infrarot-Thermometer
FR: Thermomètre infrarouge auriculaire/frontal 3-en-1
NL:3-in-1 infrarood oor- en voorhoofdthermometer
IT:Termometro a infrarossi da fronte e orecchie 3 in 1
ES: Termómetro infrarrojo frontal y auricular 3 en 1
Edco Deutschland GmbH
Siemensstr. 31 47533 Kleve
Deutschland
Made in China
Manual version 1.0

5
3-in-1 Ear and
Forehead infrared
thermometer
USER MANUAL
2
Model:MDI231
Item no.: 871125224865
0123

Catalog
1. Summary of infrared
thermometer 4
2. Safety precautions 5
3. Intended use 9
4. Temperature measurement
mode and range description 9
5. Feature 11
6. Overall description 13
7. Operation instruction 14
8. Care and cleaning 22
9. Maintenance 23
10. Calibration 23
11. Storage 24
12. Accessories 24
13. Trouble-shooting 25
14. Specications 26
15. Standard list 28
16. Disposal 29
17. Normalized symbols 30
18. EMC declaration 31
3

1. Summary of infrared
thermometer
Thank you for choosing our Infrared
Thermometer. The MDI231 Infrared
Thermometer is used to measure an
objects temperature based on the re-
lationship between temperature and
measurable infrared radiation. Sim-
ply aim the unit’s probe toward the
surface to be measured to obtain a
quick and accurate temperature. To
ensure proper use, please be sure
to read this user manual carefully,
paying close attention to the safety
precautions.
• In order to use this product correct-
ly, please read the user manual be-
fore use.
• In order to properly use this pro-
duct, please carefully read the full
text of this manual before using, in
particular the “safety precautions”
section.
• Please keep the instructions on the
side for easy checking.
Basic principles:
All objects above absolute zero tem-
perature emit certain percentage of
infrared radiation energy based on
its temperature. The amount of the
radiation energy and the distribution
of the wavelength have very close
relationship. When human body tem-
perature in 36-37°C, it emits wave-
length 9-13um of infrared radiation.
Based on this principle, according
4

to the relationship between surface
forehead temperature and eardrum
of ear temperature, we are able to
measure the human body actual tem-
perature.
2. Safety precautions
Warning !
• Use of this thermometer is not
intended as a substitute for con-
sultation with your physician. It is
dangerous for user to perform a
self-evaluation and self-treatment
based on the measuring result. Be
sure to follow doctor’s instruction.
• Keep the thermometer out of reach
of children. For accidental swal-
low of battery or other component,
please consult the doctor at once.
• The patient who suffer the external
otitis and media otitis or other ear
disease that will be prohibited to
using the product to measure ear
temperature. It may worsen the les-
ion.
• Don’t throw the battery into re.
Notice !
• The device is precision instrument,
don’t drop, tramp or impose any
vibration or impact on the thermo-
meter.
• Do not touch the lens of the probe
with your ngers, and do not dis-
semble the device by yourself.
• Before measuring forehead tempe-
rature, make sure the hair removed,
5

sweat dried.
• After you do some exercise, eating
and bathing, you should stay still
indoor about 30 minutes before
measurement.
• To make the measurement data
reliable and stable, when ambient
temperature varies a lot, the ther-
mometer should be placed indoors
for about 30 minutes before using.
• When we measure somebody con-
tinuously, the temperature should
be measured every minute, if you
need to measure yourself conti-
nuously for a short time, there are
some slight errors when you read
the temperature, which is a nor-
mal phenomenon. At this time, we
should choose the average. We re-
commend that you measure your-
self continuously maximum of three
in a unit of time, and because the
temperature of the human will con-
duct to the thermometer, it may af-
fect the accuracy of measurement.
• There is no absolute standard about
the temperature of the human, so
please try to collect the recording of
individual temperature in the usual,
as a reference for having a fever or
not.
• Do not measure the sites of scar-
red tissue or tissue compromised
by skin disorders, because sen-
sing body temperature from sites of
scarred tissue or tissue compromi-
sed by skin disorders.
• Do not measure the site of forehead
temperature if that patients has
6

trauma on forehead.
• Do not measure if that patient is
treated with certain drug therapies.
• Do not immerse the device into wa-
ter or any other liquid, and not di-
rectly sunlight exposure.
• Do not use a mobile or cordless
phone near the thermometer when
measuring.
• Body temperature may increase in
the drug within the effort time limit.
Please don’t measure.
• In order to ensure the accuracy of
measurement data, please don’t
take measurement of body tem-
perature in strong electromagnetic
interference environment (such as
microwave, high frequency equip-
ment operation environment).
• Do not forcibly insert the probe in
the ear. If you fell abnormal such
as pain during measurement, stop
using the unit. It may injure the ex-
ternal auditory canal.
• If the ear is cooled such as being
exposed to the cold for a long peri-
od, wait until the ear is warmed up,
then measure. The measured result
may be indicated low when you use
an ice bag or immediately after co-
ming home from outside in winter.
• Do not use the unit to measurement
ear temperature when the external
auditory canal is wet such as after
swimming or a bath. It may cause
measurement inaccurate.
• Do not disassemble, repair, or mo-
dify the unit.
• This thermometer is only a perso-
7

nal device, please do not use with
others.
• Do not touch the battery output
when measuring.
• The thermometer must be stored
according to the technical speci-
cations.
• The materials (ABS) of expect con-
tact with patient had passed the
ISO 10993-5 and ISO 10993-10
standard test, no toxicity, allergy
and irritation reaction. They are
compliance with the MDD require-
ments. Based on the current scien-
ce and technology, other potential
allergic reactions are unknown.
• The patent is an intended operator.
The patient can measure, read data
and replace battery under normal
circumstances and maintain the de-
vice and its accessories according
to the user manual.
• The device is not intended for PA-
TIENT transport outside a healthca-
re facility.
Recommendations
1. Don’t use this thermometer for
other purposes.
2. It is forbidden to leave the product
exposed to any chemical solvent,
direct sunshine or high tempera-
ture.
3. Don’t expose the thermometer un-
der direct sunlight long time so as
not to damage the battery.
4. Do not measure while talking on
the phone.
8

5. Please report to MANUFACTU-
RER if any unexpected operation
or events occur.
3. Intended use
This thermometer is intended to
measure ear canal and forehead
temperature at home or hospital,
including anyone, such as infants,
children and adults.
For the safety reason, children or the
baby’s temperature must be measu-
red by parent or adults.
4. Temperature
measurement mode
and range description
The infrared thermometer has the fol-
lowing measurement mode:
1. Forehead temperature measure-
ment mode -- measures the skin
surface of human forehead’s tem-
perature accurately, take the place
of traditional mercury thermometer
and electrical thermometer.
2. Ear temperature measurement
mode – measures the skin surface
of human eardrum’s temperature
accurately, take the place of tra-
ditional mercury thermometer and
electrical thermometer.
9

Normal temperature range for
different measuring position
Measuring
position
Normal
tempera-
ture(°C)
Normal
tempera-
ture(°F)
Anus 36.6-38.0 97.9-100.4
Oral 35.5-37.5 95.9-99.5
Armpit 34.7-37.3 94.5-99.1
Ear 35.5-37.8 95.9-100
Forehead 35.8-38.0 96.4-100.4
Normal forehead temperature
range for different ages
Ages
Normal
temperature
(°C)
Normal
temperature
(°F)
0-2 years old 36.4-38.0 97.5-100.4
3-10 years old 36.1-37.8 97.0-100.0
11-65 years old 35.9-37.6 96.6-99.7
>65 years old 35.8-37.5 96.4-99.5
NOTE:
The normal temperature and diffe-
rence between the different body
parts is individual. To dene yours,
measure your temperature for at
least 2 weeks at the same ear canal,
forehead position and time.
NOTE:
When consulting your physician,
communicate that which position the
temperature is measured by infrared
thermometer MDI231, note the indi-
vidual’s normal temperature range
by infrared thermometer MDI231 as
additional reference.
10

NOTE:
Because the forehead temperature
is affected obviously by the external
environment (eg: environment, air
convection and skin tone, etc), we
advice that you take the forehead
temperature only as reference. When
you have a doubt about the measure-
ment result, please use the ear canal
temperature to conrm it.
5. Feature
High reliability
This product has passed the manu-
facturer’s internal life and reliability
test, time to failure is ≥1000h.
A wide range of temperature
The measurement range:
32.0°C-43.0°C (89.6°F - 109.4°F).
High accuracy
This product has passed the infrared
thermometer performance standards
of the European Union and China
for measuring clinical requirements,
measuring clinical repeatability is no
more than ± 0.3°C (0.5°F).
Humanization design
When the temperature exceeds the
range, LCD will display the Lo or Hi
prompt.
When operating environment ex-
ceeds the designed specications,
LCD will display the Err prompt.
When the thermometer battery po-
11

wer is insufcient, it has low voltage
icon.
Has the hardware self-test function,
when hardware malfunction is detec-
ted, LCD will display the ErA or ErC
prompt.
Power saving function
Start the thermometer without any
operation, or no any operation after
temperature measurement, the ther-
mometer will shut off and LCD go out
with one short beep in 60s ± 5s.
Three-color backlight indication
function
Has designed the three-color back-
light function to indicate the tempe-
rature rang:When the correct result
is measured, the backlight from LCD
will light different color to indicate the
temperature range as below:
Temperature
Range °C
Tempera-
ture
Range °F
Indicator
Color
Duration of
light
Way of
Beep
T<37.5°C T<99.5°F Green 4 seconds 1 long
beep
37.5°C≤ T
<38.0°C
99.5°F≤ T
<100.4°F Orange 4 seconds 3 short
beep
38.0°C≤T 100.4°F≤T Red 4 seconds 3 short
beep
Memory mode
The thermometer stores the last tem-
perature measurements. The last
temperature will be automatically
displayed when it is turned on again.
The display will show “M” icon.
12

Measuring indicator light
Measuring indicator light uses a
green light to remind during the pro-
cess of temperature measurement.
6. Overall description
Main component including
Temperature
measuring probe
forehead temperature
measuring cap
Button 1
Button 2
°C/°F selector
Battery
compartment
cover
Switch
measurement
button
LCD screen
LCD display description
Ear temperature mode
Forehead temperature mode
Object temperature mode
Temperature value Temperature unit
Low voltage icon
Beep sound
Recall button
Child mode
Adult mode
13

7. Operation instruction
Preparation
1. Check battery
Replace the batteries to ensure pow-
er supply if there is low voltage icon
for the thermometer.
2. Check sensor
If have pollution and spray, please
clean it. (The cleaning method see
the chapter 8 Care and Cleaning for
detailed.) If the sensor’s lens is dam-
aged, please stop using.
3. Check thermometer
When you press the Switch meas-
urement button, the system will have
self testing of software and hard-
ware. If there are problems, LCD will
display “ErC/ErA “ symbol. If found,
please refer to the chapter 13 Trou-
ble-shooting.
4. In order to make the accurate
measuring result, put the thermome-
ter in the measurement environment
for 30 minutes.
5. Accuracy of unexpected uctua-
tions in ambient temperature may
decrease the measurement results.
When the thermometer at the same
measurement position display at
different ambient temperature, or
measure temperature in front of the
air conditioner, it will not be able to
obtain accurate results.
6. If you measure forehead temper-
ature, clean forehead and arrange
hair, make sure the forehead is na-
ked and clean, in order to ensure the
14

accuracy of measurement.
Instruction for use
1. Battery installment and
replacement
Insert new batteries when the battery
symbol appears on the display. Open
the battery compartment. Remove
the batteries and replace with new
batteries, making sure the poles are
in the right direction. Slide battery
door back until it snaps in place.
NOTE: always change batteries
when LCD displays the low battery
indicator to make sure a accurate
measurement.
Notice:
• Please observe the related national
laws of disposing the abandoned
battery and don’t litter to the gar-
bage can.
• Please take out the battery if the
device is not used for long periods
of time.
• Please don’t put the battery in the
re.
To protect the environment, dispose
of empty battery at your retail store
or at appropriate collection sites ac-
cording to national or local regula-
tions.
15

2. Function settings:
Switch temperature unit between °C
and °F:
Remove the battery compartment
cover. In temperature measuring
state, press the C/F selector, and the
selected temperature unit will be dis-
played on the screen with a “beep”
sound. Then you can proceed to tem-
perature measurements.
3. Switch between ear temperature
mode and forehead temperature
mode:
Ear temperature mode LCD screen Forehead temperature mode
Switch between ear temperature
mode and forehead temperature
mode by removing or installing the
forehead temperature measuring
cap.
4. Mode selection:
In temperature measuring state,
press “1” to select adult mode, child
mode or object temperature mode.
16

5. Enable/disable beep sound:
In temperature measuring state,
press “2” to disable or enable the
beep sound.
6. Call measurement records:
In temperature measuring state, long
press “2” for about 3s to make the
beep sound and display the meas-
urement records in the above se-
quence. Then each time you press
“2”, the previous record will be dis-
played (there are a total of up to 32
temperature value records).
7. Memory clearance:
In temperature measuring state,
press and hold “2” and meanwhile
press and hold the On/Off key for
about 3s, and the screen will be
cleared with four “beep” sounds (all
records are deleted).
17

8. Measure ear temperhature:
Press the On/Off key to turn on the
thermometer and proceed to 2s full-
screen display. Then the temperature
value of the previous measurement
will be displayed for 2s, and then the
thermometer will get into the ear tem-
perature mode with a “beep” sound.
Insert the temperature measuring
probe into the ear canal and press
the On/Off key to perform a measure-
ment, and the temperature value will
be displayed on the screen with
a “beep” sound. Such tempera-
ture value is displayed with green
green(<37.5°C), orange (37.5°C
≤temperature <38.0°C) or red
(≤38.0°C) backlight, as shown below.
NOTE:
Neonate (aged under 1): pull the au-
ricle back and downward and hold it,
so that the temperature measuring
probe can aim at the eardrum.
Child or adult (aged above 1): pull the
auricle back and upward and hold it,
so that the ear canal
will remain in a straight line and the
temperature measuring probe can
aim at the eardrum.
NOTE:
1. Keep the probe surface clean, oth-
erwise the measurement can’t be
accurate.
18

2. Clean the probe with clean cloth or
paper moistened with water or al-
cohol, and conduct measurement
after the water on the surface of
the probe all evaporates.
TEMPERATURE TAKING HINTS
- The right ear temperature may differ
from the left ear. Therefore, always
take the temperature in the same
ear.
- The ear must be free from obstruc-
tion excess earwax build-up to take
an accurate reading.
- External factors may inuence ear
temperatures, including when an
individual has:
■ Been laying on ear or other
■ Had their ears covered
■ Been exposed to very hot or very
cold temperatures, or
■ Been recently swimming or bathing
- In these cases, remove the individ-
ual from the situation and wait 30
minutes prior to tacking a temper-
ature.
■ Use the untreated ear if prescrip-
tion ear drops or other ear medi-
cation have been placed in the ear
canal.
■ Don’t use the thermometer out-
doors.
9. Measure forehead temperature:
Install the temperature measuring
cap to switch to the forehead temper-
ature mode.
19

Press the On/Off key to turn on the
thermometer and proceed to 2s full-
screen display. Then the temperature
value of the previous measurement
will be displayed for 2s, and then
the thermometer will get into the
forehead temperature mode with a
“beep” sound. Aim the temperature
measuring probe at the forehead
and press the Measure key (if you
press and hold the Measure key, the
thermometer will keep scanning with
several “beep” sounds and then com-
plete the measurement when you re-
lease the Measure key) to perform a
measurement, and the temperature
value will be displayed on the screen
with a “beep” sound. Such temper-
ature value is displayed with green
(<37.5°C), orange (37.5°C ≤tem-
perature <38.0°C) or red (≤38.0°C)
backlight, as shown below.
NOTE:
Make sure the temperature measur-
ing probe aims at and touches the
forehead (between the eyebrows)
closely.
TEMPERATURE TAKING HINTS
- Before take the temperature, please
x the forehead hair to prevent
measured deviation.
20
This manual suits for next models
1
Table of contents
Languages: