4 GTC Günes Sanayi ve Ticaret A.S. - www.gtctrade.com –Glass/Glass portable frame 72 Bifacial Cells Modules Installation Manual - Version 2 - 2022
Do not knock or use any nails or screws on or around the modules.
Avoid scratching the module. Do not place any items on the module.
Do not attempt to open, drill holes, or change part of module.
Be especially careful with the glass edges and corners of laminates (frameless modules). Make
sure the edges do not touch anything anywhere.
GTC module is a complete set along with its cables whose integrity should be kept untouched.
Do not remove the label from the modules at any time.
Only use modules with the insulation in perfect condition. Broken modules can cause exposed
live parts. Never install a damaged module.
c. Electrical Safety Precautions :
GTC modules come with the sign, , which is a warning that electric current or voltage
which can lead to personal injury if you fail to observe the instructions.
GTC modules can only be installed by professional electricians who have been trained for PV
module installation.
Keep all electrical contacts clear and dry. Do not use wet plugs, cables.
Do not remove connectors or cables on a module.
Never try to dismantle or open the junction box of any module. Opening the junction box will
void the warranty.
Ensure that the cable connections do not have cracks, contaminations, or soiling.
Before you carry out any work on electrical components, disconnect the PV module.
Match the polarities of cables and terminals when making the connections.
Do not touch damaged parts with your bare hands.
Use protective clothing and suitable, insulated tools.
Only use approved insulated tools for maintenance work on live parts.
Work in dry conditions. While connecting the module, the electrical connections, the cables and
the tools must be all completely dry.
All electrical connections must be made properly otherwise current leakages may cause sparks
with subsequent fatal injuries due to electric shocks and may even cause fires.
All connectors used in the installed system must comply with code requirements MC4
compatible. Non-compliant connectors may be sources of fire.
Once connected, solar modules always operate and generate high voltages. Never touch the
electrical connections of a solar module under any circumstances, not even if you have
disconnected the PV module (photovoltaic module) as there may be a lagged voltage due to
earthed connections.
5. INSTALLATION GUIDELINES
a. Mechanical Installation :
Always carry the GTC modules two or three people holding with two hands evenly apart from
the two long edges.
If the modules come with protection, do not remove the corner protections till modules are
mechanically installed in place.
GTC modules can be installed in various applications on building or free mounting system.
The right direction and the best tilt of the modules must be determined to obtain maximum yield
using proper tools and methods well known in the industry.
Modules may be installed in portrait or landscape orientation. If the roof has a slope over 10°,
then modules should be installed in landscape orientation.
Artificially concentrated sunlight shall not be directed on the module or panel.
A minimum 60mm recommended 100 mm clearance between the module and the mounting
surface (roof, ground, or other solid surface) is required.