Guardall DTX 15 User manual

Installation Instructions
Part No. 320902-0E
DTX 15 / 18
3
5
7
1
2
4
8
6
Diagram 1 - Description
1. Coin slot
2. Off the wall tamper (using this mounting hole
provides off the wall tamper)
3. Detector mounting holes
4. Cable entry knock-outs
5. Mirror adjustment and fixing screw
6. Pyro Detector (Do not touch)
7. Microwave range control
8. Cover screw (Loosen only - do not remove)
Guardall Limited
Lochend Industrial Estate
Newbridge, Edinburgh EH28 8PL
Technical Hotline: 0131- 333-3802
Website: www.guardall.com
Volumetric Plan View 15m / 18m
Volumetric Side View 15m / 18m
7.5m/9m
0m
7.5m/9m
2.3m
Diagram 3 - Coverage Patterns
0 4m/4.5m 7.5m/9m 12m/13.5m 15m/18m
0 4m/4.5m 7.5m/9m 12m/13.5m 15m/18m
Voltage: 12 V (9 V to 16 V dc)
Current: Quiescent – 17 mA @ 12V
Max – 22 mA @12V (All LED’s ON)
Alarm, Aux &
Tamper: Normally closed (NC). Rated at 24 V dc, 50mA
Test Input: Positive supply to enable LEDs and control
Remote Self Test
Control Input: Positive supply for system Set. Otherwise
Unset
Microwave range: 50% to 100% of range via potentiometer
1. Technical Specification
See datasheet for full information
Use in EN50131 Complaint Systems:
DTX 18 meets the requirements of TS50131-2-4:2004, Grade 3, Class II
with SW4 and SW9 ON and SW3 OFF.
DTX 15 meets the requirements of TS50131-2-4:2004, Grade 2, Class II
and is suitable for use on PD6662 Grade 3 systems with SW4 ON and
SW3 OFF.
Diagram 2 - Terminal block
10 9 8 7 6 5 4 3 2 1
NC Aux Ctrl 12 V
Test + -
NC Alarm
NC
Tamper
Red Green Yellow
SW1 Test abFault Other Fault Other
OFF Low √-√-√-
ON x √√ √ √ √
xHigh √√ √ √ √
x =don’t care
-
-
Coverage shown applies with unit mounted 2.3m high, SW2 OFF, micro-
wave at max and mirror at factory set position. Changing these may affect
approval compliance.
Declaration of Conformity :
HerebyGuardallLtd,declaresthatDTX18/100andDTX15/100areapproved
foruseinUK,Italy&EireandthatDTX18/2500,DTX15/2500,areapproved
foruseinPortugalandallareincompliancewiththeessentialrequirements
and other relevant provisions of EU Directive 1999/5/EC.
Intended use: Within a building as an intruder detection device.
Safety Information: The power feed must be fused at 5A or less.
2. Installation Location
The recommended mounting height of the detector is 2.3m. Ensure
the detector’s field of view is not obscured. Please refer to Installation
Guidance Notes available on our website or call the Technical Hotline for
further information.
3. Walk testing
Select switch 1 to ON.
The yellow LED displays PIR activity. The PIR coverage is adjusted by
loosening the two mirror locking screws, moving the mirror up or down,
then re-tighten the locking screws. Position B=18m and C=12m.
The green LED displays microwave activity. Range is adjusted via the
microwaverange control(7 in Diagram 1).The microwaveshould beset to
theminimum necessary to give the required coverage.Note that coverage
under the unit may also change.
The red LED displays unit alarms.
Walk test the area checking that alarms are indicated at the control
panel.
Check tamper operation if wired.
4. Operating Feature Selection
SW1: LED enable - See LED indications section
SW2: Pulse Count
In harsh environments select switch 2 ON (pulse count).
SW3: Microwave Day Disable
OFF - the microwave will be permanently active.
ON - microwave is disabled when system Unset.
SW4: Anti-mask / Fault Output
SW4 Faults Mask Signalled On
ON Aux + LED (if enabled) Alarm + Aux + LED (if enabled)
OFF LED Aux + LED
To reset a mask: Remove the mask, wait 30 secs, generate an alarm.
If Switch 3 (UW day disable) is ON the Anti-mask is disabled.
SW5, SW6 & SW7: Enable built-in EOL resistors for Guardall panels
SW5 SW6 SW7 EOL Connection
No EOL OFF OFF OFF Terminal 3 to 10
Alarm / Tamp ON ON OFF Terminal 3 to 10 (*1)
Alarm / Tamp
/ Aux ON ON ON Terminal 8 to 10 (*2) (*3)
(*1) To monitor Aux output on a separate zone fit external EOL resistors.
(*2) Only Px/Qx V3.2 or above, with Fault EOL option enabled.
(*3) Note: add a link between terminal 3 and 7
SW9: Anti-Mask Sensitivity
In harsh environments select switch 9 OFF.
SW10: Anti-Stealth
SW10 ON - Enhances detection for high security applications.
Pleaserefer to Installation Guidance Notesavailable onwebsite or callthe
Technical Hotline for further information.
5. Remote Self Test
With switch 4 ON, a self test is generated when the TEST Input is taken
high to low. The alarm output will signal a successful remote self test. A
failure will generate a fault condition. This is only reset by a successful
remote self test.
6. Alarm Memory
* System Set
Should an alarm occur the alarm will be memorised.
* System Unset and SW1 OFF
TEST Input Low : the red LED will remain ON (if an alarm is
memorised).
TEST Input High: the LEDs display normally without losing alarm
memory.
Memory reset occurs the next time the system is set.
7. LED Mode Setting
System Set: None
System Unset:
With SW4 OFF, the following table applies.
WithSW4 ON, SW1 OFFand TEST low, the following table appliesexcept
No Faults are displayed.
8. LED Indications
Red LED Indications:
a) Latched Alarm : ON constant.
Anti-Mask Fault: With latched alarm: Flicker...ON..Flicker..ON..etc.
No latched alarm:Flicker..OFF..Flicker..OFF..etc
Low Voltage : One Flash every second.
b) Low Voltage : One Flash every second.
Unit Alarm : ON for 3 secs.
Anti-Mask Fault : Flicker..OFF...Flicker..OFF..etc.
Green LED Indications:
Microwave Alarm :ON for 3 secs.
Microwave detection : One Flash.
Microwave Masked : 2.5 Flashes every second.
Microwave Fault : ON Dull (while Faulty).
Yellow LED Indications:
PIR Alarm : ON for 3 secs.
PIR Alarm event : One Flash.
(pulse count only)
PIR Masked : 2.5 Flashes every second.
PIR Fault : ON Dull while Faulty.
9. Warranty
All Guardall products are warranted against defects in workmanship in materials
(details available on request). In the interests of improving quality and design,
Guardall reserve the right to amend specifications without giving prior notice.
Faulty product should be returned to your supplier.
Note: Guardall recommend that the detector is regularly walk tested back to the
control panel and that installers advise their customers to do this.
Enabled Disabled
ON OFF
Enabled Disabled
Faults on Aux AM on Aux
Connected OFF
Connected OFF
Connected OFF
- -
High Sensitivity Standard
Enabled Disabled
Diagram 4 : Factory Defaults
No. Function
1 LED Enable
2 Pulse Count
3 UW Day disable
4 AM / Faults O/P
5 *EOL 1
6 *EOL 2
7 *EOL 3
8 Not used
9 Anti-Mask Sensitivity
10 Anti-Stealth
* See below
OFF
ON
1 2 3 4 5 6 7 8 9 10

Other manuals for DTX 15

1

This manual suits for next models

1

Other Guardall Security Sensor manuals

Guardall DTX 15 User manual

Guardall

Guardall DTX 15 User manual

Guardall SecuRam BASIC User manual

Guardall

Guardall SecuRam BASIC User manual

Guardall DTSx Plus User manual

Guardall

Guardall DTSx Plus User manual

Guardall DTSx Plus User manual

Guardall

Guardall DTSx Plus User manual

Guardall V12AM User manual

Guardall

Guardall V12AM User manual

Guardall Vega DX User manual

Guardall

Guardall Vega DX User manual

Guardall GP15 User manual

Guardall

Guardall GP15 User manual

Guardall V12AM User manual

Guardall

Guardall V12AM User manual

Popular Security Sensor manuals by other brands

LUDLUM 44-7 Technical manual

LUDLUM

LUDLUM 44-7 Technical manual

Benning VT 1 operating manual

Benning

Benning VT 1 operating manual

Elkron IRT600 Installation, programming and functions manual

Elkron

Elkron IRT600 Installation, programming and functions manual

Toyama T 76 252 Technical manual

Toyama

Toyama T 76 252 Technical manual

EZiCAT EZiSYSTEM user manual

EZiCAT

EZiCAT EZiSYSTEM user manual

rayence 1417WGC User & installation manual

rayence

rayence 1417WGC User & installation manual

Nexa ZMD-107 manual

Nexa

Nexa ZMD-107 manual

Jung Mini basic operating instructions

Jung

Jung Mini basic operating instructions

Velleman PIR500 user manual

Velleman

Velleman PIR500 user manual

Takex PB-100AT-KH instruction manual

Takex

Takex PB-100AT-KH instruction manual

Ansell AE3LED/3M/W/ST installation instructions

Ansell

Ansell AE3LED/3M/W/ST installation instructions

Preifer Vaccum SmartTest HLT 570 operating instructions

Preifer Vaccum

Preifer Vaccum SmartTest HLT 570 operating instructions

DMS MINI MERLIN Installation & operation manual

DMS

DMS MINI MERLIN Installation & operation manual

Panasonic HG-C Series instruction manual

Panasonic

Panasonic HG-C Series instruction manual

Tarmo 603129 instructions

Tarmo

Tarmo 603129 instructions

Hanhart PROFIL1 Instructions for use

Hanhart

Hanhart PROFIL1 Instructions for use

JRC NJJ-105 Handy Search user guide

JRC

JRC NJJ-105 Handy Search user guide

CENS ProFlex digital 1e Additional information

CENS

CENS ProFlex digital 1e Additional information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.