Red Green Yellow
SW1 Test abFault Other Fault Other
OFF Low √-√-√-
ON x √√ √ √ √
xHigh √√ √ √ √
x =don’t care
-
-
Coverage shown applies with unit mounted 2.3m high, SW2 OFF, micro-
wave at max and mirror at factory set position. Changing these may affect
approval compliance.
Declaration of Conformity :
HerebyGuardallLtd,declaresthatDTX18/100andDTX15/100areapproved
foruseinUK,Italy&EireandthatDTX18/2500,DTX15/2500,areapproved
foruseinPortugalandallareincompliancewiththeessentialrequirements
and other relevant provisions of EU Directive 1999/5/EC.
Intended use: Within a building as an intruder detection device.
Safety Information: The power feed must be fused at 5A or less.
2. Installation Location
The recommended mounting height of the detector is 2.3m. Ensure
the detector’s field of view is not obscured. Please refer to Installation
Guidance Notes available on our website or call the Technical Hotline for
further information.
3. Walk testing
Select switch 1 to ON.
The yellow LED displays PIR activity. The PIR coverage is adjusted by
loosening the two mirror locking screws, moving the mirror up or down,
then re-tighten the locking screws. Position B=18m and C=12m.
The green LED displays microwave activity. Range is adjusted via the
microwaverange control(7 in Diagram 1).The microwaveshould beset to
theminimum necessary to give the required coverage.Note that coverage
under the unit may also change.
The red LED displays unit alarms.
Walk test the area checking that alarms are indicated at the control
panel.
Check tamper operation if wired.
4. Operating Feature Selection
SW1: LED enable - See LED indications section
SW2: Pulse Count
In harsh environments select switch 2 ON (pulse count).
SW3: Microwave Day Disable
OFF - the microwave will be permanently active.
ON - microwave is disabled when system Unset.
SW4: Anti-mask / Fault Output
SW4 Faults Mask Signalled On
ON Aux + LED (if enabled) Alarm + Aux + LED (if enabled)
OFF LED Aux + LED
To reset a mask: Remove the mask, wait 30 secs, generate an alarm.
If Switch 3 (UW day disable) is ON the Anti-mask is disabled.
SW5, SW6 & SW7: Enable built-in EOL resistors for Guardall panels
SW5 SW6 SW7 EOL Connection
No EOL OFF OFF OFF Terminal 3 to 10
Alarm / Tamp ON ON OFF Terminal 3 to 10 (*1)
Alarm / Tamp
/ Aux ON ON ON Terminal 8 to 10 (*2) (*3)
(*1) To monitor Aux output on a separate zone fit external EOL resistors.
(*2) Only Px/Qx V3.2 or above, with Fault EOL option enabled.
(*3) Note: add a link between terminal 3 and 7
SW9: Anti-Mask Sensitivity
In harsh environments select switch 9 OFF.
SW10: Anti-Stealth
SW10 ON - Enhances detection for high security applications.
Pleaserefer to Installation Guidance Notesavailable onwebsite or callthe
Technical Hotline for further information.
5. Remote Self Test
With switch 4 ON, a self test is generated when the TEST Input is taken
high to low. The alarm output will signal a successful remote self test. A
failure will generate a fault condition. This is only reset by a successful
remote self test.
6. Alarm Memory
* System Set
Should an alarm occur the alarm will be memorised.
* System Unset and SW1 OFF
TEST Input Low : the red LED will remain ON (if an alarm is
memorised).
TEST Input High: the LEDs display normally without losing alarm
memory.
Memory reset occurs the next time the system is set.
7. LED Mode Setting
System Set: None
System Unset:
With SW4 OFF, the following table applies.
WithSW4 ON, SW1 OFFand TEST low, the following table appliesexcept
No Faults are displayed.
8. LED Indications
Red LED Indications:
a) Latched Alarm : ON constant.
Anti-Mask Fault: With latched alarm: Flicker...ON..Flicker..ON..etc.
No latched alarm:Flicker..OFF..Flicker..OFF..etc
Low Voltage : One Flash every second.
b) Low Voltage : One Flash every second.
Unit Alarm : ON for 3 secs.
Anti-Mask Fault : Flicker..OFF...Flicker..OFF..etc.
Green LED Indications:
Microwave Alarm :ON for 3 secs.
Microwave detection : One Flash.
Microwave Masked : 2.5 Flashes every second.
Microwave Fault : ON Dull (while Faulty).
Yellow LED Indications:
PIR Alarm : ON for 3 secs.
PIR Alarm event : One Flash.
(pulse count only)
PIR Masked : 2.5 Flashes every second.
PIR Fault : ON Dull while Faulty.
9. Warranty
All Guardall products are warranted against defects in workmanship in materials
(details available on request). In the interests of improving quality and design,
Guardall reserve the right to amend specifications without giving prior notice.
Faulty product should be returned to your supplier.
Note: Guardall recommend that the detector is regularly walk tested back to the
control panel and that installers advise their customers to do this.
Enabled Disabled
ON OFF
Enabled Disabled
Faults on Aux AM on Aux
Connected OFF
Connected OFF
Connected OFF
- -
High Sensitivity Standard
Enabled Disabled
Diagram 4 : Factory Defaults
No. Function
1 LED Enable
2 Pulse Count
3 UW Day disable
4 AM / Faults O/P
5 *EOL 1
6 *EOL 2
7 *EOL 3
8 Not used
9 Anti-Mask Sensitivity
10 Anti-Stealth
* See below
OFF
ON
1 2 3 4 5 6 7 8 9 10