Guardall GP15 User manual

© 2021 Carrier Fire & Security Australia Pty Ltd. All rights reserved. 1 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 •ISS 15MAR21
Guardall Detectors GP15, GQ20,
GD20, GCQ and GCD Installation
Manual
Quick Installation
Opening the device
The devices are supplied in the unlocked position. If locked.
Use a flat bladed terminal driver and turn the locking
mechanism ¼ turn anti- clockwise.
Slide the front down and towards you to remove.
For ceiling mount devices remove the facia by
turning it anti-clockwise, and then unlock as above.
Figure 1: Locking Mechanism
Figure 2: Ceiling facia removal
Mounting and cable entry
Location
Ensure you have the correct device for the intended
application, and that it is sited correctly in the desired
location. The field of view should be free from obstacles and
any potential false alert causes.
Devices should be mounted on stable internal surfaces and
are NOT suitable for use externally.

2 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Avoid common false alert causes
Ensure the devices field of view is not obstructed
Install on a flat stable surface only
Ensure surrounding structures are stable
For internal use only
Screws & Fixing
A minimum of 2 opposing fixing holes should be used to
ensure maximum stability. When corner mounting care
should be taken to ensure the chassis is not twisted, if the
corner is uneven then two fixings on the same side would be
acceptable. Where removal from mounting detection is
required you must ensure that the tamper fixing is opposite
to at least one of the corner or wall fixings.
Dependent on the mounting substrate, suitable fixings may
be required. The size and type will depend on the choice of
fixing screw.
•
Minimum screwsize 3.5 X16mm CSK
•
Maximum screw size 4.0X70mm CSK

3 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Cable Routing
If the bottom cable entries are used, care should be taken
to ensure that the cable passes around the post as shown.
This helps avoid cable snagging when refitting the front
chassis.
NOTE: Do not use the screw fixing points to route cable.
Corner mount
Wall, ceiling & flat surface mount
Cable routing
Terminal Block tilt

4 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Wiring and EOL selection
The device allows you to wire to control equipment in
several different ways. To aid wiring and inspections of
cable termination the terminal block can be tilted forwards
or removed entirely.
EOL wiring is considered the most secure. The example
shown assumes you are connecting to a Premier Elite
control panel. For other wiring types, please refer to the
manufacturer’s instructions for your equipment.
The O/C position can be used for other wiring types,
including use of resistor values which are not included on
the device Terminal block identification.
Terminal block identification
1. + to Aux 12V
2. - to Aux 0V
3. A - Alarm
4. B - Alarm
5. C –Tamper
6. D –Tamper
7. RLED can be used to control the LED for walk
testing.
Terminal block
RLED terminal
The RLED (Remote LED) terminal can be used to control the
LED for walk testing from the panel.
To use the RLED feature put switch 1 in the up position
which will disable the LED. When an output is triggered 0V
is applied to the RLED terminal which will enable the LED.
Mode selection
G2 all models
This is the default state for optimum catch performance
and false activation immunity. Switch 2 and the lens
obscuration slider should be in the down position.
•GP15 15m @ 90° compliant to EN50131-2-2,
INCERT and PD6662
•GQ20 20m @ 90° compliant to EN50131-2-2,
INCERT and PD6662
•GD20 20m @ 85° compliant to EN50131-2-4,
INCERT and PD6662

5 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Pet Mode (GP15, GQ20 & GD20)
When using Pet mode, switch 2 and the lens obscuration
slider should both be placed in the UP position.
•GP15 10mtr @ 90° up to 35kg pet immunity
•GQ20 12mtr @ 90° up to 20Kg pet immunity
•GD20 12mtr @ 85° up to 20Kg pet immunity
Note:
Never use CloakWise with PET mode.
CloakWise™ GD20 & GCD
CloakWise is a proprietary detection algorithm that can
distinguish the presence of an intruder even if the
unauthorised person attempts to mask or ‘cloak’ their
presence. Utilising advanced signal processing
techniques to both microwave and PIR channels, the
CloakWise technology can recognise cloaking attempts
and detect accordingly. CW mode will also provide
excellent detection when the ambient temperature is
close to human body temperature.
Note: Never use CloakWise with PET or LOW mode.
GCQ & GCD Slider
Leave in the default position
Do not use

6 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Testing, commissioning & LED indications
When installation is complete, the device should be
thoroughly walk tested to ensure the desired protection is
being achieved, and any adjustments to the device are made
to cater for the specific location and any local site conditions.
Note: LED’s are disabled during normal use if the RLED
switch is ON.
State
Colour
Flash
Warm up
Flash 0.5s on0.5soff
Alarm
PIR only on
GD20/GCD
MW only on
GD20/GCD
Walk test
Walk test all devices to ensure you have adequate
coverage, and that there are no obstructions in the
detection area.
GD20 & GCD Microwave Range Adjustment
Devices are supplied with the microwave adjustment
potentiometer set at the mid- point.
The microwave should be adjusted according the area to
be protected, and great care should be taken to ensure
the microwave cannot “see” beyond protected area. LED
indication of the microwave
pickup allows for accurate
setting of the detection area.
•Power up the device
•Walk test the device taking note of the
LED
indications.
•Adjust the Microwave range until the desired
coverage is achieved.
GD20 Microwave Coverage
GCD Microwave Coverage
Resistance & voltage readings
Resistance and voltage readings should be recorded at the
time of installation.
•Voltage readings should be taken at the device
•Resistance reading should be taken at the CIE or
ACE where the circuit is terminated.

7 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Variants
Guardall GP15
G2 Coverage
Pet Coverage

8 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Guardall GQ20
G2 Coverage
Pet Coverage

9 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Guardall GD20
G2 Coverage
Pet Coverage

10 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Guardall GCQ
DO NOT USE
Guardall

11 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
GCD
Optional wall or ceiling mount brackets
Part Numbers
Pack of 10 brackets AFU-0004
Screws & Fixings
To ensure maximum stability 2 screws should be used for
either mounting option.
Dependent on the mounting substrate, suitable fixings may
be required. The size and type will depend on the choice of
fixing screw.
Ceiling mount
No.6-No.8 CSK 15-25mm
Wall mount
No.6 Pan head 15-25mm
Ceiling mount installation

12 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Wall mount installation
Specification
Specifications
GP15, GQ20, GD20, GCQ, GCD
Alarm System
EN50131-2-2 (GP15, GQ20, GCQ)
EN50131-2-4 (GD20, GCD), EN50131-1,
PD6662:2017 Grade 2 Class II
Product Type
AKB-0004 (GP15) AKC-0004 (GQ20) AKD-
0004 (GD20) AKF-0004 (GCQ) AKG-0004
(GCD)
Operating
Voltage
9-15Vdc (12V + - 25%)
Maximum
Current
(measured at
12V)
GP15, Q20, GCQ –12mA
GD20 –13mA
GCD –17mA
Quiescent
Current
(measured at
12V)
Relative
Humidity
Operating
Temperature
Weight
GP15, GQ20, GCQ –9.3mA
GD20 –11.5mA
GCD –15.5mA
0-95% non-condensing
-10°C to 55°
GP15, GQ20, GCQ (no ring or fascia) –106g
GP15, GQ20 (with fascia and insert) –124g
GCQ (with ring) –163g
GD20, CD (no ring or fascia) –110g
GD20 (with fascia and insert) –128g
GCD (with ring) –167g
Dimensions
Wall Mount: Width 65mm, Height
112mm, Depth 43mm.
Ceiling Mount: 125mm Diameter,
Depth 43mm.
Regulatory information
Manufacturer
Made in U.K for Carrier Fire & Security Australia
Pty Ltd
10 Ferntree Place, Notting Hill, VIC, 3168,
Australia
Year of
manufacture
The first two digits of the product serial number
(located on the product identification label) are
the year of manufacture.
Compliance

13 / 13 P/N MAINST-GUARDALLPIR • REV 1.0 • ISS 15MAR21
Disclaimer
The customer is responsible for testing to determine the
suitability of this product for specific applications. In no event
is Carrier Fire & Security Australia Pty Ltd. responsible or
liable for any damages incurred by the buyer or any third
party arising from its use, or their inability to use the product.
Guardall is a Carrier brand.
Contact information
For contact information, see
www.firesecurityproducts.com.au
This manual suits for next models
4
Table of contents
Other Guardall Security Sensor manuals
Popular Security Sensor manuals by other brands

Pioneering Technologies
Pioneering Technologies Safe T Sensor Installation Instructions and Care & Use Manual

TESTO
TESTO 317-1 instruction manual

PCB Piezotronics
PCB Piezotronics 236B Installation and operating manual

HomeMatic
HomeMatic HM-Sec-MDIR-3 Installation and operating manual

Alarmtech
Alarmtech MC 346 instruction manual

INIM Electronics
INIM Electronics EB0020 manual