GUARDEON G-OP-DPIR W Guide

G-OP-DPIR W|G-OP-DPIR U
V.G2018-10-24
250cm - top
100cm
Bottom
OUTDOOR VOLUMETRIC DETECTOR WITH DOUBLE
ADJUSTABLE HEADS CABLED AND WIRED VERSION
INSTALLATION AND USE MANUAL
G-OP-DPIR W & G-OP-DPIR U is an innovative passive infrared sensor for outdoor use, which has two
completely independent and individually adjustable detection heads. This allows obtaining a
great functioning versatility and at the same time, if correctly installed, an excellent decreasing
of false alarms.
The sensor operates with the IR heads in “OR” or “AND” modes: the last one generates alarm
only when both IR heads detect intrusion. It is possible to select the priority of the head which
causes alarm.
from each other just for the alarm transmission mode:
G-OP_DPIR W : WIRED version, with OptoMOS outputs (NC electronic relay)
G-OP-DPIR U: UNIVERSAL version as it is a low absorption version that can be connected by
wire to any wireless transmitter located in the appropriate case at the bottom of the
sensor.
B
Each detection head is equipped with a Fresnel lens that builds 5 sectors, each divided in a
couple of beams (fig. B-1)
DETECTION AREA
1
1 2
A
60 cm60 cm 60 cm
130 cm
One sector detail at 10 m
READ CAREFULLY THIS MANUAL BEFORE INSTALL YOUR NEW ALARM
SYSTEM. KEEP THIS MANUAL FOR FUTURE REFERENCE.
ONLY QUALIFIED TECHNICIAN MUST INSTALL THIS DEVICE.
INSTALLER MUST FOLLOW CURRENT REGULATIONS.
THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY IMPROPER USE OF
THE PRODUCT, INCORRECT INSTALLATION OR FAILURE TO COMPLY WITH
INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL
SYSTEMS.
Installation height of the center of the sensor must be between 100cm and 250 cm(fig. A1)
The detection arear is max 12 meter long and 100° wide (fig. A-2)
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

The sensore has a IP54 protection level against dust and liquids.
To mantain the IP54 level it is mandatory to insert the o-rings provided.
If possible, it is suggested to install the sensor protected against weathering; do not point
high pressure water jets to the sensor.
This sensor has been designed to guarantee a very high immunity to light interference;
however, a very bright light can produce a range decrease.
It is recommended to pay attention during the installation and avoid, as much as possible,
sensitive elements.
Infrared detector is sensitive to the “amount of heat” produced by a moving body.
The maximum range of the sensor (measured in meters) is referred to a human body.
However the same “amount of heat” may be produced by a smaller body at lower
distances (dog), or by a larger one at greater distances (vehicle).
On outdoor installations, use the “AND” mode for an high immunity to unwanted alarms,
and point both heads towards the same direction (but shifted) to avoid missed detections.
clothes hung, etc. This avoid unwanted detections.
During adjustment, perform several detection tests to verify the correct working of the
sensor. Al tests must be done WITH THE COVER in place.
pointing.
For best IR “sensitivity” adjustment, start setting the sensitivity to minimum (turn
completely counterclockwise the trimmers) and point the heads downwards.
Gradually increase the sensitivity and change the heads orientation until obtain detection
only inside the wanted area.
The sensor may detect pets (no pet-immune function).
F
INSTALLATION (PLACEMENT)
DYES NO
Range
C): the joint of each IR head
allows to adjust the orientation.
To obtain a reliable detection, it is recommended to mount the detector in the way that the
D).
YES YES
CNO NO
INSTALLATION (PRECAUTIONS)
Never point the heads directly towards
detections.
water puddles, wet roads, smooth concrete
surfaces, paved roads.
of heat (very strong sources) or infrared (other
security systems, photocells...) to cause alarms.
Do not point the heads causing parallel beams to the ground.
Do not point towards open space.
NO
YES NO
E
Tight the joint screws once finiched the adjustment
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

TECHNICAL
BATTERY DURATION (ESTIMATED) IS PROPORTIONAL TO:
• HEAT CYCLES OF THE BATTERY WHICH AFFECT CHARGE CAPACITY AND DURATION
• WORKING TEMPERATURE OF THE BATTERY (E.G.: AT TEMPERATURE LOWER THAN 0°C THE BATTERY DURATION MAY DECREASE OF 50 %)
• NUMBER OF DETECTIONS TO WHICH THE SENSOR IS SUBJECT: IF THE SENSOR IS INSTALLED IN HIGH FREQUENCY OF PASSAGE, THE BATTERY DURATION WILL DECREASE DRAMATICALLY
G-OP-DPIR-W G-OP-DPIR-U
Power supply 12 V DC Battery. The sensor can be powered with two
different voltage : 3,6V DC or 9V DC
Absorption *Stand-by: about 8 mA
Alarm: about 24 mA
Stand-by: about 15 µA
Alarm: about 8 mA
Autonomy (estimated) ** -About 2 years at normal use
Stabilization Time (at power-up) About 30 seconds (with LED blinking) About 5 seconds
Quiet Time between detections - About 30 seconds
Detection technologies Infrared (double PIR head with joint) Infrared (double PIR head with joint)
Installation height - center of detector 1,0 to 2,2 m 1,0 to 2,2 m
Detection area (H x W x D) *Max 12 m
100° wide (each IR head)
Max 12 m
100° wide (each IR head)
IR head adjustment Orientation completely independent
(vertically and horizontally)
Orientation completely independent
(vertically and horizontally)
Sensitivity Independent for each head (trimmers)
from 30% (L) to 100% (H)
Independent for each head (trimmers)
from 30% (L) to 100% (H)
Alarm logics OR, AND, Directional AND OR, AND, Directional AND
Wired outputs - Relay (OptoMOS) OptoMOS, N.C. type
(open if power off)
Max 40 V DC / 100 mA
Alarm
Tamper
Max 40 V DC / 100 mA
Alarm output
Tamper output
Low battery output
LEDs 2 red LEDs (IR heads detection)
1 blue LED for alarm
2 red LEDs (IR heads detection)
1 red LED for alarm
Temperature / Humidity -40 ÷ +70 °C / 95 % (relative) -40 ÷ +70 °C / 95 % (relative)
Case / IP degree / IK degree ABS antiUV / IP54 / IK10 ABS antiUV / IP54 (main body) / IK10
Dimension (H x W x D) / Weight 190 x 85 x 75 mm / 410 g 190 x 85 x 113 mm
Internal space for transmitter (H x W x D) - 20 x 70 x 30 mm
Accessories included n. 2 lens cover for curtain effect
n. 2 pre-cut adhesive masks
* All the data are approximate, for sensor in NORMAL mode at operating temperature of 21 °C. THE MAX RANGE DEPENDS SIGNIFICANTLY ON ENVIRONMENT TEMPERATURE.
** Mean value for 10 detections-alarms/day + supervision.
OptoMOS, N.C. type
(open if power off)
n. 2 lens cover for curtain effect
n. 2 pre-cut adhesive masks
Battery clip for 2 x 3,0 v battery (CR123A)
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

G
It is recommended to disable the LED and BUZZER (DIP4 = OFF) after the test.
G-OP-DPIR-W (WIRED)
IR2 detection LED
IR1 detection LED
BUZZER
TX / ALARM LED
TMP
Anti-opening tamper
Terminals
The ALARM and
TAMPER outputs are
OptoMOS relay,
N.C. type (opened if no
power supply)
Max 40 V DC / 100 mA
IR2 connector
IR1 connector
JP5 (Anti-removal
tamper)
Closed = disabled
Opened = enabled
JP7 (TX.LED)
Closed = LED enabled
Opened = LED disabled
R25 (IR1 sensitivity)
Clockwise = increase
Cntclockwise = decrease
R26 (IR2 sensitivity)
Clockwise = increase
Cntclockwise = decrease
JP4 (BUZZER)
(only if DIP4 = ON)
Closed = enabled
Openedo = disabled
JP6 (TAMPER TMP)
Closed= disabled
Opened = enabled
DIP-1÷6
Sensor settings
(see table)
DIP-SWITCH
OFF ON
DIP1 AND / OR AND OR
DIP2 Environment INDOOR
High sensitivity
OUTDOOR
Low sensitivity
DIP3 AND type NORMAL DIRECTIONAL
DIP4 Signals from IR1.LED,
IR2.LED and BUZZER DISABLED ENABLED (the BUZZER
depends on JP4)
DIP5 Anti-shadowing DISABLED ENABLED
DIP6 Not used Leave OFF
Sometimes the heads detection area can be too wide and it can be a potential trouble if in the
area to be protected there are tree branches, curtains, windows, etc.
In this case, it is possible to reduce the detection area by masking some beams with the
accessories provided, to have detection only from beams oriented towards stable zones.
Head with lens cover
Lens cover
! Verify that the two
lateral hooks are
correctly locked !
ADHESIVE MASK
This type of mask allows to select exactely which beams can detect: it ispossible to leave covered
the zones with unwanted movement or limit the detection only for some sectors.
LENS COVER
The lens cover - when mounted on head - creates a CURTAIN detection. With this lens cover, the
detection opening beam of the lens is reduced to 20° (keeping the same detection range).
The lens cover mount on heads thanks to an interlocking system.
Apply on both heads
the adhesive masks
provided.
Use a cutter to
remove the strips
and discover the
sectors
ACCESSORIES
Example
(front view)
135
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

G-OP-DPIR-U ( UNIVERSAL)
I
OUTPUT CONNECTOR
(provided cable)
1
It is recommended to disable the LED and BUZZER (DIP4 = OFF) after the test, to increase
the battery life.
IR2 detection LED
IR1 detection LED
BUZZER
TX / ALARM LED
Connect here (use
special cable) the
trasmitter
TMP
Anti-opening tamper
POWER connector
voltages: 3,6 V or 9 V
IR2 connector
IR1 connector
JP5 (Anti-removal
tamper)
Closed = disabled
Opened = enabled
JP7 (TX.LED)
Closed = LED enabled
Opened = LED disabled
R25 (IR1 sensitivity)
Clockwise = increase
Cntclockwise = decrease
R26 (IR2 sensitivity)
Clockwise = increase
Cntclockwise = decrease
JP4 (BUZZER)
(only if DIP4 = ON)
Closed = enabled
Openedo = disabled
JP6 (TAMPER TMP)
Closed = disabled
Opened = enabled
DIP-1÷6
Sensor settings
(see table)
DIP-SWITCH
OFF ON
DIP1 AND / OR AND OR
DIP2 Environment INDOOR /
High sensitivity
OUTDOOR /
Low sensitivity
DIP3 AND type NORMAL DIRECTIONAL
DIP4 Signals from IR1.LED,
IR2.LED and BUZZER DISABLED ENABLED (the BUZZER
depends on JP4)
DIP5 Anti-shadowing DISABLED ENABLED
DIP6 Pause between alarms Quiet time (30 seconds) Alarms without pause
All outputs are
OptoMOS relay,
N.C. type (opened if no
power supply)
Max 40 V DC / 100 mA
Outputs cable
(connect to transmitter)
Transmitter placement
2
3
Connector
(connect to OUT.CN)
Alarm
(yellow wires)
Low Battery
(white wires)
Tamper
(red wires)
Transmitter
Max. 155x45x35 mm
Cord-gasket
Insert in the proper slot
and leave the free space
for water drainage
Bottom case
Visor
Output cable
Sensor
Lens cover
Tamper
Cover
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

POWER-ON
If the sensor is already powered (or at battery change), before proceed it is necessary to
disconnect the battery, open the jumper JP6 and hold the tamper switch for about 3 seconds:
the circuit will be completely discharged and will be possible to start-up the sensor correctly.
The sensor must be powered EXCLUSIVELY if set as follows:
DIP1 = OFF Detection mode: AND
DIP2 = -- ON or OFF
DIP3 = OFF Normal AND
DIP4 = ON LED and BUZZER enabled
DIP5 = OFF Anti-shadowing OFF
DIP6 = ON Alarm without quiet time
JP6 = OPENED Anti-opening tamper enabled
JP5 = CLOSED Anti-removal tamper excluded
JP7 = CLOSED Alarm/transmission LED enabled
R25 = Minimum UPPER head sensitivity trimmer
R26 = Minimum LOWER head sensitivity trimmer
Each time the sensor is correctly powered, starts the “stabilization”: during this phase the IR
detection LEDs blink and the buzzer emits “beep”. It is important to mantain the sensor in quiet
(no detection) for example placing it in its box.
Wait the sensor ends the stabilization before proceed with installation: the sensor will be ready
about 20 s after the LEDs blink.
OR / AND / DIRECTIONAL AND - DIP1 + DIP2
OR (DIP1 = ON - DIP3 = any)
The sensor goes in alarm when one SINGLE IR head
detects movement.
It’s possible to point the IR heads to protect
coverage.
NOTE: the OR logic can be used only on indoor
environments (DIP2 = OFF) but never on outdoor;
when used on outdoor environment the risk of
NORMAL AND (DIP1 = OFF + DIP3 = OFF)
The sensor goes in alarm only when BOTH IR heads
detect movement within an “AND” time.
starts; if the second IR head detects over this time,
the sensor backs at rest without alarm.
A single IR head detection does not generate alarm.
The IR heads must be oriented to the same
direction.
The “AND” time cannot be changed.
DIRECTIONAL AND (DIP1 = OFF + DIP3 = ON)
It is the same “AND” above, but with control of the detection order.
The sensor goes in alarm only if the detection starts from the UPPER IR head (farthest area) and
then (within the “AND” time) the LOWER IR head (nearest area).
In this mode the detection has a “directionality”: the sensor distinguishes the approach to the
protected area (alarm) but ignores moving away.
L
M
N
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk

EU Declaration of Conformity
The full text of the EU Declaration of Conformity is available at the internet address:
www.guardeon.dk
This manual may be subject to change without notice
BATTERY (MOD. G-OP-DPIR-U-K)
LOW BATTERY
When the battery is low and must be replaced:
the sensor activates the “low battery” output (mod. G-OP-DPIR-U).
The blue TX/ALARM LED blinks 9 times (it must be enabled JP7 = CLOSED). The LED blinks
after each alarm or supervision transmission.
Note: the low battery alerts will continue until the battery is replaced.
BATTERY REPLACEMENT
When the battery must be replaced:
Disconnect the old battery.
Close the jumper JP5 (anti-removal) and open the jumper JP6 (anti-opening) then press
and hold the tamper switch for at least 3 seconds (circuit discharge).
Connect the new battery (see the par. “Power-on”).
QUIET TIME (MOD. / G-OP-DPIR-U) - DIP6
With the DIP6 it is possible to enable the QUIET TIME between two consecutive alarms:
QUIET TIME = OFF DIP6 = ON
The sensor transmits/signals alarm at each detection (depends on OR/AND mode).
This mode allows the installer to adjust installation of the sensor.
This mode is the factory setting.
QUIET TIME = ON DIP6 = OFF
After a detection with alarm (depends on OR/AND mode) – the sensor stops the alarm
signallings for the “quiet time”.
WARNING: during the quiet time NO DETECTION must happens, otherwise the quiet time
restert! If the quiet time ends without detections, the sensor enables alarm signallings.
The quiet time is about 30 seconds (cannot be changed).
The quiet time MUST be enabled in normal working because reduces the battery
consumption.
The G-OP-DPIR-W model works always without the QUIET TIME (leave DIP6 = OFF).
ANTI-REMOVAL TAMPER
The sensor has two types of protection against tampering attempts: anti-opening of the cover
and anti-removal. In case of tampering the sensor sends the “tamper” radio code or activates
the “tamper” output (according to the model).
The ALARM/TX LED switches on in case of tamper events (if JP7 = CLOSED).
ANTI-OPENING
Protection against cover openings. It is managed by jumper JP6:
JP6 = CLOSED EXCLUDED
JP6 = OPENED ACTIVE
ANTI-REMOVAL
Protection against removal from installation position: controls the tamper switch on the back of
the case (normally closed because the sensor is on the wall).
It is managed by jumper JP5:
JP5 = CLOSED EXCLUDED
JP5 = OPENED ACTIVE
NOTE: the two tampers are in series.
ANTI-SHADOWING - DIP5
This function - when enabled - increase the immunity
to false alarms when in harsh environments due to
fast lightings, changes of sun lightings, shadowing
(caused for example by moving trees).
To use this function, the sensor MUST work in AND
mode.
When using this function DO NOT apply the lens
cover or the adhesive mask on upper IR head!
It is possible to use the lens cover or the adhesive
mask on lower IR head.
NO!
YES
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk
This manual suits for next models
1
Table of contents
Other GUARDEON Security Sensor manuals