EU Declaration of Conformity
The full text of the EU Declaration of Conformity is available at the internet address:
www.guardeon.dk
This manual may be subject to change without notice
BATTERY (MOD. G-OP-DPIR-U-K)
LOW BATTERY
When the battery is low and must be replaced:
the sensor activates the “low battery” output (mod. G-OP-DPIR-U).
The blue TX/ALARM LED blinks 9 times (it must be enabled JP7 = CLOSED). The LED blinks
after each alarm or supervision transmission.
Note: the low battery alerts will continue until the battery is replaced.
BATTERY REPLACEMENT
When the battery must be replaced:
Disconnect the old battery.
Close the jumper JP5 (anti-removal) and open the jumper JP6 (anti-opening) then press
and hold the tamper switch for at least 3 seconds (circuit discharge).
Connect the new battery (see the par. “Power-on”).
QUIET TIME (MOD. / G-OP-DPIR-U) - DIP6
With the DIP6 it is possible to enable the QUIET TIME between two consecutive alarms:
QUIET TIME = OFF DIP6 = ON
The sensor transmits/signals alarm at each detection (depends on OR/AND mode).
This mode allows the installer to adjust installation of the sensor.
This mode is the factory setting.
QUIET TIME = ON DIP6 = OFF
After a detection with alarm (depends on OR/AND mode) – the sensor stops the alarm
signallings for the “quiet time”.
WARNING: during the quiet time NO DETECTION must happens, otherwise the quiet time
restert! If the quiet time ends without detections, the sensor enables alarm signallings.
The quiet time is about 30 seconds (cannot be changed).
The quiet time MUST be enabled in normal working because reduces the battery
consumption.
The G-OP-DPIR-W model works always without the QUIET TIME (leave DIP6 = OFF).
ANTI-REMOVAL TAMPER
The sensor has two types of protection against tampering attempts: anti-opening of the cover
and anti-removal. In case of tampering the sensor sends the “tamper” radio code or activates
the “tamper” output (according to the model).
The ALARM/TX LED switches on in case of tamper events (if JP7 = CLOSED).
ANTI-OPENING
Protection against cover openings. It is managed by jumper JP6:
JP6 = CLOSED EXCLUDED
JP6 = OPENED ACTIVE
ANTI-REMOVAL
Protection against removal from installation position: controls the tamper switch on the back of
the case (normally closed because the sensor is on the wall).
It is managed by jumper JP5:
JP5 = CLOSED EXCLUDED
JP5 = OPENED ACTIVE
NOTE: the two tampers are in series.
ANTI-SHADOWING - DIP5
This function - when enabled - increase the immunity
to false alarms when in harsh environments due to
fast lightings, changes of sun lightings, shadowing
(caused for example by moving trees).
To use this function, the sensor MUST work in AND
mode.
When using this function DO NOT apply the lens
cover or the adhesive mask on upper IR head!
It is possible to use the lens cover or the adhesive
mask on lower IR head.
NO!
YES
Guardeon Aps. Vandtårnsvej 100 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: info@guardeon.dk