GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: inf[email protected]GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: inf[email protected]
11
OUTDOOR DUAL TECHNOLOGY DETECTOR
INSTALLATION AND USE MANUAL
G-OP-WPIR-W and U is a curtain detector for protection of doors and windows.
This device has double technology detection: it integrates two infrared passive modules and a
pulsed microwave module, designed to obtain a very narrow detection beam.
The alarm is generated only when both technologies detect at the same time, avoiding false
alarms.
The device is provided with automatic temperature compensation of its partameters.
Its dimensions – particularly reduced in height and width – allow an easy installation in the
narrow spaces available on doors and windows.
The sensor is protected from removal risk, thanks to an integrated anti-removal system.
READ CAREFULLY THIS MANUAL BEFORE INSTALL YOUR NEW ALARM
SYSTEM. KEEP THIS MANUAL FOR FUTURE REFERENCE.
ONLY QUALIFIED TECHNICIAN MUST INSTALL THIS DEVICE.
INSTALLER MUST FOLLOW CURRENT REGULATIONS.
THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY IMPROPER USE OF
THE PRODUCT, INCORRECT INSTALLATION OR FAILURE TO COMPLY WITH
INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL
SYSTEMS.
A
TECHNICAL
DETECTION AREA
BATTERY DURATION (ESTIMATED) IS PROPORTIONAL TO:
HEAT CYCLES OF THE BATTERY WHICH AFFECT CHARGE CAPACITY AND DURATION
WORKING TEMPERATURE OF THE BATTERY (E.G.: AT TEMPERATURE LOWER THAN 0°C THE BATTERY DURATION MAY DECREASE OF 50 %)
NUMBER OF DETECTIONS TO WHICH THE SENSOR IS SUBJECT: IF THE SENSOR IS INSTALLED IN HIGH FREQUENCY OF PASSAGE, THE BATTERY DURATION WILL DECREASE DRAMATICALLY
THE MAX RANGE DEPENDS SIGNIFICANTLY ON ENVIRONMENT TEMPERATURE.
Power supply
8 ÷ 14 V
DC
n. 1 lithium battery pack, 6 V
Absorption *
Stand-by: about 8 mA Stand-by: about 25 µA
Alarm: about 5 mA
Autonomy (estimated) **
- About 2 years
Stabilization Time (at power-up)
About 120 seconds About 120 seconds
Quiet Time between detections ***
- About 30 seconds
TEST mode lasting
-5 minutes (at the end, the sensor backs to
NORMAL mode even if J.MODE = CLOSED)
Detection technologies
Infrared (double head) + Pulsed microwave Infrared (double head) + Pulsed microwave
Microwave frequency / working mode
24 GHz / Pulsed 24 GHz / Pulsed
Detection Area (H x W x D) *
Door: 3 x 2,5 x 0,3 m
Window: 1,2 x 0,8 x 0,2 m
Door: 3 x 2,5 x 0,3 m
Window: 1,2 x 0,8 x 0,2 m
Radio working frequency
- -
Radio range
- -
Radio signalling
- -
Wired outputs
OptoMOS, N.C. type
Max 60V /100mA / 16Ω
Insulation: 1500V
Alarm
Tamper
OptoMOS, N.C. type
Max 60V / 75mA / 10Ω
Insulation: 1500V
Alarm
Tamper
Low Battery
LED signalling
2 red LED (IR heads detection)
1 green LED (microwave detection)
1 blue LED for alarm
2 red LED (IR heads detection)
1 green LED (microwave detection)
1 blue LED for alarm
Temperature **** / Humidity
-40 ÷ +70 °C / 95 % -40 ÷ +70 °C / 95 %
Case
ABS antiUV ABS antiUV
Dimension (H x W x D)
40 x 330 x 30 mm 40 x 330 x 30 mm
Internal space for transmitter (H x W x D)
- 20 x 70 x 30 mm
*All the data are approximate, for sensor in NORMAL mode at operating temperature of 21 °C
** Mean value for 50 detections-alarms/day + supervision
*** Sensor working in NORMAL mode
**** Automatic parameters adjustment with temperature, linear compensation
1
2
DIP2 = ON
DIP2 = OFF
ver.: 2019-06-11_1_fr
G-OP-WPIR-W and -U
G-OP-WPIR-W (wired) G-OP-WPIR-U (Universal)
WINDOW frame
installa�on
DOOR frame
installa�on
GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: inf[email protected]
2
DO NOT CUT OR PUNCH
Push the cables through the cable gland until
it breaks: in this way the sheath will open just
where necessary, bonding to the cables and
ensuring a higher protection.
PRECAUTIONS
Detector must be installed protected from the elements. Install protected from direct rain.
This sensor has been designed to guarantee a very high immunity to light interference;
however, a very bright light can produce a range decrease.
It is recommended to pay attention during the installation and avoid, as much as possible,
sensitive elements.
puddles, wet roads, smooth concrete surfaces, paved roads.
Infrared detector is sensitive to the “amount of heat” produced by a moving body.
The maximum range of the sensor (measured in meters) is referred to a human body.
However the same “amount of heat” may be produced by a smaller body at lower
distances, or by a larger one at greater distances. It should be considered therefore that
the range of any passive infrared sensor is a RELATIVE measure (referring to a human
body) and NOT ABSOLUTE.
The sensor is highly immune to false alarms caused by presence of regular mosquito nets
or rollers within the detection area, provided that nets are always taut and rollers are fully
raised or lowered. If these indications are not met, increase both the risk of false alarms
and the battery consumption for G-OP-WPIR-U.

clothes hung, etc. This avoid unwanted detections.
During adjustment, perform as detection tests as necessary to obtain a correct sensor
behavior.
The sensor may detect pets (no pet-immune function).
B
C
FE
D
The detector must be installed only in horizontal position over the opening to protect, oriented
The detector must be installed with the side that presents the LEDs towards OUTSIDE (garden,
backyard, balcony…) and the opposite side towards INSIDE (door or window) to protect:
LED side: towards outside
If the anti-opening tamper is active, the sensor transmits alarm.
INSTALLATION (PLACEMENT)
It is recommended to disable the LEDs (J.LED = OPENED) after the test.
YES NO
1
YES NO
2
IR2 detection LED
IR1 detection LED
TX / ALARM LED
MW detection LED
Terminals
Infrared head IR2
Infrared head IR1
Fixing screw Fixing screw
Cable gland (model -W)
Microwave MW
Anti-opening tamper
J.LED
Closed = LED enabled
Opened = LED disabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
DIP-1÷2
Sensor settings
DIP-SWITCH
OFF ON
DIP1 Anti-removal Active Excluded
DIP2 Detection type Window (low sensitivity) Door (high sensitivity)
Range
G-OP-WPIR-W (wired)
GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: inf[email protected]
3
LEARNING/PAIRING (ONLY G-OP-WPIR-R )
AN LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON Anti-removal tamper excluded
DIP2 = -- ON or OFF
DIP3 = OFF
DIP4 = -- ON or OFF
J.TMP = OPENED Anti-opening tamper active
J.LED = CLOSED LEDs active
J.MODE = CLOSED Test Mode
3. On control panel/receiver: enter in radio zone learning (“learning by tamper” or “AN” mode).
4. Without any detection press and hold the tamper switch until the BLUE LED turns on:
the detector transmits its AN learning radio code (the BLUE LED stay on for about 2
seconds)
verify the control panel/receiver learned the radio code (press again the tamper switch in
case the learning failed)
DETECTION LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON Anti-removal tamper excluded
DIP2 = -- ON or OFF
DIP3 = OFF
DIP4 = -- ON or OFF
J.TMP = CLOSED Anti-opening tamper disabled
J.LED = CLOSED LEDs active
J.MODE = CLOSED Test Mode
3. On control panel/receiver: enter in radio zone learning (“detection learning”).
4. Make the sensor detect until the BLUE LED lights on:
• the sensors transmits its alarm radio code
• verify the control panel/receiver learned the radio code (make another detection with the
sensor in case the learning failed)
TEST AND NORMAL MODES (ONLY G-OP-WPIR-U )
With J.MODE jumper is possible to set the sensor in TEST or NORMAL mode:
TEST mode: J.MODE = CLOSED
The sensor transmits / signals alarm at each detection.
This mode allows the installer a correct tuning of the detector.
To exit from TEST mode and back to NORMAL, open the J.MODE jumper: some seconds
after last detection, the sensor signals the exit by sequentially turning on the LEDs (round
trip).
The sensor exit automatically from TEST after about 5 minutes – even without opening
the J.MODE jumper. The automatic exit is also signalled by the sequential turning on of
the LEDs.
If necessary to increase the TEST mode time, simply open and close the J.MODE jumper
The TEST mode is set as default.
NORMAL mode: J.MODE = OPENED
It’s the mode the detector MUST be set when in normal working.
In this mode – after last detection and alarm transmission – the detector wait for a “quiet
time” before to consider a new intrusion (alarm).
If during this time there is no detection the sensor will back ready to a new detection,
otherwise the quiet time is extended.
The quiet time is about 30 seconds (not changeable).
The NORMAL mode allow a lower consumption and a longer battery life.
G H
IR2 detection LED IR2 detection LED
IR1 detection LED IR1 detection LED
TX / ALARM LED TX / ALARM LED
MW detection LED MW detection LED
Battery connector Battery connector
Infrared head IR2 Infrared head IR2
Infrared head IR1 Infrared head IR1
Microwave MW Microwave MW
Anti-opening tamper Anti-opening tamper
J.LED
Closed = LED enabled
Opened = LED disabled
J.LED
Closed = LED enabled
Opened = LED disabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.MODE
Closed = Test Mode
Opened = Normal Mode
J.MODE
Closed = Test Mode
Opened = Normal Mode
DIP-1÷4
Sensore settings DIP-1÷4
Sensor settings
OUTPUTS CONNECTOR
(for provided cable)
DIP-SWITCH
OFF ON
DIP1 Anti-removal Active Excluded
DIP2 Detection type Window (low sensitivity) Door (high sensitivity)
DIP3 Radio test Normal working Transmission Test
DIP4 Supervision OFF ON
DIP-SWITCH
OFF ON
DIP1 Anti-removal Active Excluded
DIP2 Detection type Window (low sensitivity) Door (high sensitivity)
DIP3 Not used Leave OFF
DIP4 Not used Leave OFF
1
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
G-OP-WPIR-W works only in TEST mode.
G-OP-WPIR-R G-OP-WPIR-U (universal)
G-OP-WPIR-R - NOT AVALIABEL IN DENMARK
G-OP-WPIR-R - NOT AVALIABEL IN DENMARK
GUARDEON Security Systems ApS. Vandtårnsvej 100, 2860 Søborg CVR: 37769568 T: +45 72 17 00 28 W: guardeon.dk E: inf[email protected]
4
ANTI-REMOVAL TAMPER (INCLINOMETER)
The sensor is provided with an anti-removal function (that can be activated with DIP1) which
establishes whether the sensor is moved from the installing position.
This function is activated just when the sensor is in the HORIZONTAL position and afterwards
it is inclined. In order to activate the removal detection, it is necessary to put the sensor
horizontally: from now on the anti-removal is activated; if the sensor moves it indicates tamper
alarm.
POWER-ON
BEFORE POWER THE SENSOR
If the sensor is already powered (or at battery change), before proceed it is necessary to
disconnect the battery, open the jumper J.TMP and hold the tamper switch for about 10
seconds: in this way the circuit will be completely discharged and will be possible to start-up the
sensor correctly.
G-OP-WPIR-W and U
Power the sensor only after all the wiring is completed.
When the sensor is powered, the LEDs light on is sequence for some seconds: the sensore starts
the “Stabilisation period”
The Stabilisation period takes about 2 minutes (the infrared and microwave LEDa light on
in case of detection)
At the end of the stabilization time, the sensor is ready for use.
BATTERY (ONLY G-OP-WPIR-U)
Caution, the device works by lithium battery.
Replace the battery exclusively with one of the same type.
Follow the polarity indicated in the instructions.
Dispose of empty batteries following the current regulations, even in case of equipment
disposal.
In case of leakage, protect your hands with special gloves.
LOW BATTERY
When the battery is low, the sensor the activates the “low battery” output (model -Universal).
The low battery alert low battery output is activated after three alarm or
supervision transmissions (if in test, it is sent after each transmission).
Depending on the control panel or receiver model, the alert is visualized on display or LED.
Note: the low battery alerts will continue until the battery is replaced.
BATTERY REPLACEMENT
When the battery must be replaced:
Disconnect the old battery
Open the jumper J.TMP , then press and hold the tamper switch for at least 3 seconds
(circuit discharge)
Connect the new battery (see the par. “Power on”)
Output Cable
(connect to the transmitter)
Transmitter Space
(maximum dimension)
2
3
I
L
Battery Sensor board Transmitter
Connector
(connect to CN.OUT)
Low Battery
(yellow wires)
Tamper
(white wires)
Alarm
(red wires)
4

This manual suits for next models

1

Other GUARDEON Security Sensor manuals

GUARDEON G-AIR2-100 User manual

GUARDEON

GUARDEON G-AIR2-100 User manual

GUARDEON G-OP-SCPIR-K Guide

GUARDEON

GUARDEON G-OP-SCPIR-K Guide

GUARDEON GPVM-B200T User manual

GUARDEON

GUARDEON GPVM-B200T User manual

GUARDEON G-OP-DPIR W Guide

GUARDEON

GUARDEON G-OP-DPIR W Guide

Popular Security Sensor manuals by other brands

Polon-Alfa TUN-4046 Installation and maintenance manual

Polon-Alfa

Polon-Alfa TUN-4046 Installation and maintenance manual

Retlux RDT 100 user manual

Retlux

Retlux RDT 100 user manual

Yates Y-530 user manual

Yates

Yates Y-530 user manual

jablotron JA-111ST manual

jablotron

jablotron JA-111ST manual

Safescan 155 Series manual

Safescan

Safescan 155 Series manual

Niko 350-41750 Programming guide

Niko

Niko 350-41750 Programming guide

Redwall V Series installation instructions

Redwall

Redwall V Series installation instructions

Zublin Swiss Garde 360 Presence DALI Master A-Comfort... quick guide

Zublin

Zublin Swiss Garde 360 Presence DALI Master A-Comfort... quick guide

B.E.G. LUXOMAT PD9-DIGI-FC Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT PD9-DIGI-FC Installation and operating instruction

DST ObservAir operating manual

DST

DST ObservAir operating manual

STEINEL IS 180-2 installation instructions

STEINEL

STEINEL IS 180-2 installation instructions

B.E.G. LUXOMAT PD3-1C Installation and operating instruction

B.E.G. LUXOMAT

B.E.G. LUXOMAT PD3-1C Installation and operating instruction

Siemens OOH740 Technical manual

Siemens

Siemens OOH740 Technical manual

GST I-9101 quick start guide

GST

GST I-9101 quick start guide

Thermokon WK02+ manual

Thermokon

Thermokon WK02+ manual

Leak-Guardian 2500 Guide

Leak-Guardian

Leak-Guardian 2500 Guide

Astronics Trig-Tek 850A user manual

Astronics

Astronics Trig-Tek 850A user manual

Honeywell 997 installation instructions

Honeywell

Honeywell 997 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.