GUARDE
ON
Security
Sys
tems
ApS.
V
andt
årnsvej
100,
2860
Søbor
g
CVR:
37769568
T
:
+45
72
17
00
28
W:
guardeon.dk
E:
inf
[email protected]3
LEARNING/PAIRING (ONLY G-OP-WPIR-R )
AN LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON Anti-removal tamper excluded
DIP2 = -- ON or OFF
DIP3 = OFF
DIP4 = -- ON or OFF
J.TMP = OPENED Anti-opening tamper active
J.LED = CLOSED LEDs active
J.MODE = CLOSED Test Mode
3. On control panel/receiver: enter in radio zone learning (“learning by tamper” or “AN” mode).
4. Without any detection press and hold the tamper switch until the BLUE LED turns on:
the detector transmits its AN learning radio code (the BLUE LED stay on for about 2
seconds)
verify the control panel/receiver learned the radio code (press again the tamper switch in
case the learning failed)
DETECTION LEARNING
1. Power on the sensor and wait the end of stabilization.
2. Set DIP-SWITCH and JUMPERs as follows:
DIP1 = ON Anti-removal tamper excluded
DIP2 = -- ON or OFF
DIP3 = OFF
DIP4 = -- ON or OFF
J.TMP = CLOSED Anti-opening tamper disabled
J.LED = CLOSED LEDs active
J.MODE = CLOSED Test Mode
3. On control panel/receiver: enter in radio zone learning (“detection learning”).
4. Make the sensor detect until the BLUE LED lights on:
• the sensors transmits its alarm radio code
• verify the control panel/receiver learned the radio code (make another detection with the
sensor in case the learning failed)
TEST AND NORMAL MODES (ONLY G-OP-WPIR-U )
With J.MODE jumper is possible to set the sensor in TEST or NORMAL mode:
TEST mode: J.MODE = CLOSED
The sensor transmits / signals alarm at each detection.
This mode allows the installer a correct tuning of the detector.
To exit from TEST mode and back to NORMAL, open the J.MODE jumper: some seconds
after last detection, the sensor signals the exit by sequentially turning on the LEDs (round
trip).
The sensor exit automatically from TEST after about 5 minutes – even without opening
the J.MODE jumper. The automatic exit is also signalled by the sequential turning on of
the LEDs.
If necessary to increase the TEST mode time, simply open and close the J.MODE jumper
The TEST mode is set as default.
NORMAL mode: J.MODE = OPENED
It’s the mode the detector MUST be set when in normal working.
In this mode – after last detection and alarm transmission – the detector wait for a “quiet
time” before to consider a new intrusion (alarm).
If during this time there is no detection the sensor will back ready to a new detection,
otherwise the quiet time is extended.
The quiet time is about 30 seconds (not changeable).
The NORMAL mode allow a lower consumption and a longer battery life.
G H
IR2 detection LED IR2 detection LED
IR1 detection LED IR1 detection LED
TX / ALARM LED TX / ALARM LED
MW detection LED MW detection LED
Battery connector Battery connector
Infrared head IR2 Infrared head IR2
Infrared head IR1 Infrared head IR1
Microwave MW Microwave MW
Anti-opening tamper Anti-opening tamper
J.LED
Closed = LED enabled
Opened = LED disabled
J.LED
Closed = LED enabled
Opened = LED disabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.TMP
Closed = Tamper disabled
Opened = Tamper enabled
J.MODE
Closed = Test Mode
Opened = Normal Mode
J.MODE
Closed = Test Mode
Opened = Normal Mode
DIP-1÷4
Sensore settings DIP-1÷4
Sensor settings
OUTPUTS CONNECTOR
(for provided cable)
DIP-SWITCH
OFF ON
DIP1 Anti-removal Active Excluded
DIP2 Detection type Window (low sensitivity) Door (high sensitivity)
DIP3 Radio test Normal working Transmission Test
DIP4 Supervision OFF ON
DIP-SWITCH
OFF ON
DIP1 Anti-removal Active Excluded
DIP2 Detection type Window (low sensitivity) Door (high sensitivity)
DIP3 Not used Leave OFF
DIP4 Not used Leave OFF
1
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
It is recommended to disable the LEDs (J.LED = OPENED) after the test to increase the
battery life.
G-OP-WPIR-W works only in TEST mode.
G-OP-WPIR-R G-OP-WPIR-U (universal)
G-OP-WPIR-R - NOT AVALIABEL IN DENMARK
G-OP-WPIR-R - NOT AVALIABEL IN DENMARK