732.28.427
732.28.427
HDE 25.06.20
HDE 25.06.20
5/5
en
Subject to
alteration
© 2020 by Häfele GmbH & Co KG
Adolf-Häfele-Str. 1 · D-72202 Nagold www.hafele.com
3.5. Update Mode
Option 1: Update Mode by App
• In case the rmware is outdated, the user will be notied inside the Connect Mesh App. There the user can start and
perform the update of the mesh device (more information in the specic Häfele Connect Mesh App).
Option 2: Manual Update by Power On/O
• Start the device (red status LED ashes).
• Switch ON/OFF your Connect Mesh 2 Channel Interface 4 times at consistent intervals of 2 seconds each.
(Attention: Wait until the red status led is o, before switching ON again.)
• The status LED will light constantly to signify the device is in Update Mode and can be updated in the Häfele Connect
Mesh App.
3.6. Reset
Option 1: Reset by App
• In case the device is provisioned and connected through the app, the user can reset the mesh device via the Connect
Mesh App (more information in the specic Häfele Connect Mesh App).
Option 2: Manual Reset by Power On/O
• Switch ON/OFF your Connect Mesh 2 Channel Interface 8 times at consistent intervals of 2 seconds each.
(Attention: Wait until the red status led is o, before switching ON again.)
• The ashing LED will identify that the device is again in provisioning mode.
Now use the Häfele Connect Mesh App to provision the device.
3.7. Status LED
Status LED Behavior Meaning
Off The Connect Mesh 2 Channel Interface is either switched OFF or check your
connections again.
Flashing The Connect Mesh 2 Channel Interface is in provisioning mode and is ready to be
added to an existing BLE Mesh network.
On The Connect Mesh 2 Channel Interface is either in normal operation mode or in
OTA update mode.
If it is OTA update mode, it will remain in OTA update mode for 60 seconds or until
the power is uninterrupted.