1
When the ambient humidity is too high, in
COOLING or DEHUMIDIFYING mode,
there may be water dropped in the air outlet.
During Heating operation, after starting
the unit, the indoor fan motor will not
rotate immediately to prevent cold air from
blowing out.
Please wait
?
Operation points
Operation of air conditioner Anti-cold air blowing out
3-minuteprotectionfunction
If start the unit immediately only after it is
turned off, the compressor will start after 3
minutes have elapsed to protect the compressor.
Defrosting function
During Heating operation, when frost formed
on the heat exchanger of outdoor unit, the
air conditioner will de frost
automatically for several
minutes. During defrosting,
both the fan of indoor and
outdoor unit do not run. After
finishing defrosting, the air
conditioner will automatically
resume operation.
Change of fan speed
InCOOLINGmode,theairsendingissetatAUTO,whenthe
indoortemperatureisnearthesettemperature,thefanspeed
willlowerautomatically.InHEATINGmode,whenroom
temperaturereachesthesettemperature,thecompressorwill
stoprunning,andthefanwillchangetoLOWFANorstop.
InDEHUMIDIFYINGmode,thefanspeedwillchange
automatically.
Hint
When the air conditioner is in Heating mode,
it absorbs heat from outside and release to
indoors. So the outdoor temperature may
affect the Heating effect.
Power failure resume function (please set and use this function according to actual condition)
After setting power failure resume function, if there is a sudden power failure during unit
operation, when power on for again, the unit will resume the previous state.
Setting method: when the wire controller is in ON state (except for TIMER and FAN mode),
press the SLEEP button for 10 times in 5 seconds, after the buzzer sounds 4 times, the unit will
change to POWER FAILURE RESUME function.
Cancellation method: press the SLEEP button 10 times in 5 seconds, after the buzzer 2 times, the
POWER FAILURE RESUME function is cancelled.
Note: After the unit is set POWER FAILURE RESUME function, if there is a sudden power
failure in using, during this period of time if there is no need to use the unit for a long time,
please cut off power to prevent the air conditioner from automatically resuming to the
previous setting if power failure resumes, or press the ON/OFF button to turn off the unit
after power failure resumes.