HAKO FA-430 User manual

®
2. SPECIFICATIONS
4. OPERATION
4. OPERATION
1. PACKING LIST AND PART NAMES
1
 1
1
Main filter (inside main unit)
1
             10pcs.
FUME EXTRACTION
3.WARNINGS, CAUTIONS, NOTES AND EXAMPLES
2012.3
MA01866XZ120301
Copyright © 2012 HAKKO Corporation. All Rights Reserved.
●Duct set (not included)
1. Open the upper cover and then remove the
plastic bag from the main filter.
2. Put the main filter on the main unit. Set the
filter with the arrow pointing down
(as shown in the illustration).
3. Fit the pre-filter on top of the main filter.
(orange side facing up )
●Attach the duct
2. Fit the net on the nozzle. (Figure.2)
3. Insert the duct into the open port.
If using one duct, ensure the cap is in place
on the unused port.
When using two ducts, please store the cap
inside the main unit next to the main filter as
shown in Figure 3 (right).
B. How to attach bench top hood.
A. How to attach duct set
(Fig.1)
Duct set (Duct / Adapter / Rectangular nozzle or
Round nozzle / Net)
Net
*When using the duct for B2410
(φ75 mm), set the 3 inch
adapter to the main unit.
Rectangular nozzle
*1 When using 2 ducts
*2 It is an initial value of collection efficiency based on counting method for airborne dust collected
by a single plate of filter (unfolded).
●HAKKO FA-430
When using a bench top hood,
the following parts are required:
●3 inch adapter
●3 inch duct (φ75 )
●Duct band
*Refer to “7. PARTS LIST” for part numbers.
*The standard duct for the HAKKO FA-430
can not be used to connect a bench top hood.
Do not absorb combustible, explosive or corrosive gas.
Store the fume extraction unit in a dry place.
Do not block the exhaust vent of the fume extraction unit.
Use only genuine HAKKO replacement parts.
Turn the power off when not in use, or left unattended.
Turn the power off when changing parts or storing the HAKKO FA-430.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the appliance.
●
●
●
●
●
●
●
●
●
To prevent accidents or damage to the HAKKO FA-430, be sure to observe the followings:
●
●
●
●
Do not operate the fume extraction without the filter; otherwise it may cause the unit to malfunction.
Hold the plug when inserting or removing the cord in/from the outlet.
Do not allow the HAKKO FA-430 to become wet, or use it with wet hands.
While using the HAKKO FA-430, don’t do anything which may cause bodily harm or physical damage.
Thank you for purchasing the
HAKKO FA-430 Fume Extraction system.
Please read this manual before operating the
HAKKO FA-430
.
Keep this manual readily accessible for reference.
Please check to make sure that all items
listed below are included in the package.
This product includes such features as electrically conductive plastic parts and grounding of the unit
as measures to protect the device to be soldered from the effects of static electricity. Be sure to observe
the following instructions:
1. The plastic parts are not insulators, they are conductors. When making repairs or replacing
parts, take sufficient care not to expose live electrical parts or damage insulation materials.
2. Be sure to ground the unit during use.
4. Close the upper cover
Be sure the pre-filter lies flat and completely
covers the top of the main filter with no gaps.
1. Refer to Figure 1(right), and attach the
nozzle and adapter to the duct.
Insert the nozzle and adapter until it stops,
turn the nozzle clockwise. Make sure the
nozzle and adapter are firmly attached.

Twist the nozzle tight enough to avoid
coming off.
Instruction Manual
HAKKO FA-430 Fume extraction system
Power cord
Cap (inside main unit)
Pre-filter
Instruction manual 1
Power Consumption
Suction Capacity *1
Filtering Efficiency *2
Duct diameter
Dimensions
Weight (w/o cord)
*Specifications and design are subject to
change without notice.
or
Duct Adapter
Round nozzle
●Option
Bench top hood
3 inch adapter
WARNING
CAUTION
(Fig.3)
(Fig.2)
Cap
120W
High   Medium  Low
4.7m³/min 3.7m³/min 2.8m³/min
High: 99.96% / Medium·Low:99.97%
φ55 mm
330(W) x 366(H) x 343(D) mm
7.5 kg
風扇組合
插頭
1Insert the nozzle
until it stops.
Turn the nozzle clockwise.
2
Be sure the duct is
facing in the
proper direction
during assembly.
or
Instruction manual in the language of Japanese, English, Chinse, French, German and Korean
can be downloaded from the HAKKO Document Portal.
(Please note that some languages may not be available depending on the product.)
HAKKO FA-430
Fume extraction
Cap
Main filter
Pre-filter
Power cord
●Set the filter Pre-filter
(orange side
facing up)
Main filter
(facing the
arrow
downward)
●Fume extraction unit
1. Connect the power cord to the power
receptacle on the right of the unit.
2. Plug the power cord into a ground wall socket.
3. Turn the power switch on. Power lamp will light up.
4. Adjust the flow suitable for working environment
by using flow selection switch.
5. Adjust the angle of the duct and nozzle as needed
for optimal performance.
Close the cover before turning the power switch on.
●Do not block the open port on purpose.
●When the fan is running, do not open the
upper cover.
●Turn the power off when not in use.
Failure to do so may result in shorter filter life.
●If it passes more than 2500 hours or one year
since the HAKKO FA-430 is used, replace the
main filter with new one at once.
If using the main filter over replacement
timing, doing so may result in damage to
the main unit.
Replacement Indicator Lamp
(Pre-filter/ orange)
Low
High
Medium
Replacement Indicator Lamp
(Main filter/ red)
Power lamp (Green)
Flow selection
switch
Filter life reset
Power switch
3 inch
adapter
3 inch
duct
Duct band
Exhaust vent
7. PARTS LIST
●HAKKO FA-430
Pre-filter
Main filter
Cap
Knob
Power switch
Power cord, 3 wired cord but no plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord& European plug
Power cord, 3 wired cord & BS plug
Power cord, 3 wired cord & Australian plug
Power cord, 3 wired cord & Chinese plug
Power cord, 3 wired cord & American plug
Power cord, 3 wired cord & SI plug
Power cord, 3 wired cord & BR plug
1
2
3
4
5
6
A1572
A1573
B3619
B1486
B2852
B2421
B2422
B2424
B2425
B2426
B2436
B3508
B3550
B3616
Part No. Part Name Specifications
Item No.
Specifications
●Nothing happens when the power switch
is turned on.
●Orange lamp keeps flashing after replacing
the pre-filter.
●Red lamp is flashing for 5 seconds just
after turning the power switch on.
●Red lamp keeps flashing after replacing
the main filter.
●Red lamp lights up.
●All lamp flashes at the same time.
Is the power cord disconnected ?
Connect it.
Is the main filter set properly ?
Fit the main filter properly before turning
on the power switch again.
Is the flow control set to RESET ?
Adjust the flow suitable for working
environment by using the flow
selection switch.
When replacing the filter, Is the flow
selection switch adjusted to RESET with
the power switch on ?
Make sure that power switch is ON,
and set the flow selection switch to
RESET again.
When replacing the filter, Is the flow
selection switch adjusted to RESET with
the power switch on?
Make sure that power switch is on
and set the flow selection switch to RESET.
Lift the main filter more than 3 seconds.
Main filter needs to be replaced.
Recommend replacing the main filter
otherwise performance
will be reduced.
Main filter has exceeded its service life
and was never replaced. It has passed
more than 2500 hours since it is used.
Main filter must be replaced. Failure to do
so may result in damage to the unit.
Contact your HAKKO representative
because it is necessary to repair the
main unit.
1
2
10
5
7
4
36
34
9
9
8
11
●Option
Duct set /
Rectangular nozzle
Duct set /
Round nozzle
Duct
Adapter
Adapter
Rectangular nozzle
Round nozzle
Bench top hood
Net
Duct
Duct band
Duct (1) / Adapter (1)
Rectangular nozzle(1) / Net (1)
Duct (1) / Adapter (1)
Round nozzle (1) / Net (1)
φ 55 mm 
For 3 inch
5 pcs.
For 3 inch (φ 75 mm) 
Set of 2
C1571
C1572
B3642
B3620
B3621
B3622
B3623
B2418
B3625
B2410
B2416
10
11
Item No. Part No. Part Name
1
2
3
4
5
6
7
8
9
7. PARTS LIST
6. TROUBLE SHOOTING GUIDE
5. MAINTENANCE
Performing proper and periodic maintenance extends the product life. Wear of the product will
differ depending on work environment, the quality and quantity of the solder and flux.
Apply the following service procedure as dictated by the conditions of the usage.
●How to replace the filter
●The lamp status indicates appropriate time to replace the main filter and pre-filter.
If continuing to use the main filter or pre-filter after the lamp status indicates it is time for
replacement, it may result in reduced performance and/or subsequent damage to the unit.
A. Pre-filter
●In case of replacing the pre-filter only with the red and orange lamp flashing.
B. Main filter
*If not replacing the main filter after the lamp indicated to replace it, the red lamp
will flash for 5 seconds every time the power switch is turned on.
●When replacing the filter, set the flow selection switch to RESET
without turning off the power switch.
Pre-filter lamp (orange) flashes.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and remove the pre-filter only. Fit the new pre-filter on top of the main filter
so that it lies flat with no gaps, then close the upper cover.
Set the flow selection switch back to the previous position.
The fan will start running and the unit will return to a normal operating condition.
Pre-filter : 80% of the pre-filter is clogged or it was used for 200 hours. (The orange lamp flashes.)
Pre-filter lamp (orange) and main filter lamp (red) flash.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and then remove the pre-filter only. Fit the new pre-filter on top of the
main filter so that it lies flat with no gaps, then close the upper cover.
Set the flow selection switch back to the previous position.
After 5 seconds are passed, the red lamp will be turned off.
1
2
3
4
Turning on the power
After
5 seconds
MAIN
POWER
PRE
MAIN
POWER
PRE
After
5 seconds
MAINPRE
POWER
MAIN
POWER
PRE MAIN
POWER
PRE
MAIN
POWER
PRE
MAIN
POWER
PRE MAIN
POWER
PREMAINPRE
POWER
MAIN
POWER
PRE
1
2
3
4
Pre-filter lamp (orange) and main filter lamp (red) flash.
Set the flow selection switch to RESET with the power switch on. (The fan will stop.)
Open the upper cover and then remove both main filter and pre-filter.
Replace the filters with the new filters, fit them in the main unit and close the upper cover.
Set the flow selection switch back to the previous position.
The fan will start running and the unit will return to a normal operating condition.
1
2
3
4
MAIN
POWER
PRE MAIN
POWER
PREMAIN
POWER
PRE Flashing
Lighting
OFF
Do not lift the main filter when replacing the pre-filter.If the main filter is lifted for more than
3 seconds with the power switch on and the flow control set to RESET,
the used number of the pre-filter are reset to zero.
●Filter replacement timing
Main filter : When the 10th pre-filter needs replacing. (The orange and red lamp flash.)
Replacing the filter without following the procedure will disrupt the timing for filter replacement
and may cause the overuse of the filters and subsequent damage to the unit.
10 pcs.
HAKKO FA-430 counts used number of the pre-filter in order to determine the
remaining life of the main filter. There are a few points to observe when replacing filters.
Read “How to replace the filter” and follow the procedure.
Replacing the filter without following the procedure may cause the overuse
of the main filter and subsequent damage to the unit.
220 - 240V
India
220V KTL , 230V CE
230V CE , U.K.
China

Popular Air Cleaner manuals by other brands

Robur AD 14 Instructions for installation, use and maintenance manual

Robur

Robur AD 14 Instructions for installation, use and maintenance manual

Philips GP7101 user manual

Philips

Philips GP7101 user manual

HealthWay 20600-3 Deluxe user manual

HealthWay

HealthWay 20600-3 Deluxe user manual

Novy 841.400 operating instructions

Novy

Novy 841.400 operating instructions

Honeywell F300 Product data

Honeywell

Honeywell F300 Product data

Trebs Whisper Air manual

Trebs

Trebs Whisper Air manual

Hama 186438 operating instructions

Hama

Hama 186438 operating instructions

Lifa Air HepaClean 1100 Operating and maintenance manual

Lifa Air

Lifa Air HepaClean 1100 Operating and maintenance manual

AROEVE MK04 user manual

AROEVE

AROEVE MK04 user manual

HoMedics TOTALCLEAN QS-APT20 quick start guide

HoMedics

HoMedics TOTALCLEAN QS-APT20 quick start guide

PureMate NaturoPure PM 380A instruction manual

PureMate

PureMate NaturoPure PM 380A instruction manual

Medify Air MA-40UV Instruction manual and  warranty information

Medify Air

Medify Air MA-40UV Instruction manual and warranty information

Dyson Pure Hot + Cool HP01 user manual

Dyson

Dyson Pure Hot + Cool HP01 user manual

Sharp FP-F60U-W Operation manual

Sharp

Sharp FP-F60U-W Operation manual

Air Oasis iAdaptAir S user manual

Air Oasis

Air Oasis iAdaptAir S user manual

Jafanda JF999 user manual

Jafanda

Jafanda JF999 user manual

Philips AC4072/18 user manual

Philips

Philips AC4072/18 user manual

Honeywell HT-380 Series owner's manual

Honeywell

Honeywell HT-380 Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.