FOR MORE INFO REFERENCE OIM MANUAL P/N FSG–MNL–00210 7
Figure 10. Foam Off Popup Confirmation
After confirmation, all discharges previously providing FOAM continue to provide water ONLY, until closed
individually.
3. USING SMARTCAFS WITH SAM
SAM also interfaces with a HALE SmartCAFS system. When SAM initializes, the SmartCAFS air compressor
(clutch) is engaged and remains engaged unless manually disengaged from the SmartCAFS display/control-
ler. (Reference FSG-MNL-00157, UV SmartCAFS Installation and Operation Manual.) To utilize CAFS with the
SAM system, activate a CAFS associated Quickset from the Auto Mode Home screen or CAFS associated pre-
set from the Valve X via the Select Discharge screen (discharge valve control screen). The CAFS system can
also provide traditional FOAM in addition to CAFS.
It is important to note that when operating SAM with SmartCAFS, that a CAFS (wet, med, or dry) preset (or
Quickset) activates preset #1 on the CAFS system; and that a foam only (FOAM) preset (or Quickset) acti-
vates preset #7 on the CAFS system.
Prior to activating a CAFS associated Quickset or preset, if the apparatus is equipped with an automatic or
manual dual tank (ADT or MDT) or manual single tank (MST) selector, place the selector in position to deliver
the desired foam concentrate.
Once the SmartCAFS system is active, the SmartCAFS display may be used to control the CAFS system as if
the apparatus did not have SAM. Reference FSG-MNL-00157, UV SmartCAFS Installation and Operation
Manual. Additionally, all foam compatibility and flushing notes/recommendations apply when using
SmartCAFS with SAM (see FSG-MNL-00157).
NOTE
Any discharge plumbed into the CAFS manifold prior to the air injection point will be FOAM ONLY
capable. Although this is NOT typical it is supported by SAM via the FOAM label.
ALTHOUGH SMARTFOAM AND SMARTCAFS BOTH UTILIZE THE LABEL FOAM, ON SAM A FOAM LA-
BELED DISCHARGE BALLOON DOES NOT ENABLE THE SAME PRESET ON THE SMARTFOAM AND
SMARTCAFS SYSTEMS.
3.1 Activating A CAFS Quickset
To activate a CAFS ready Quickset, perform the following.
A. If equipped, set ADT, MDT, or MST Selector to desired foam source.
B. Touch desired Quickset. (All CAFS available discharges are labeled with one of the following
words: DRY, MED, or WET.) See Figure 11.