98346C (03/07)
SJ2Q*1A
NOTE: It is important to insure proper ventilation. Allow a
minimum clearance of 6 inches (152 mm) in front and 3 inches
(76mm) in the rear of the unit. If unit is to be installed in an
enclosure, allow the following clearances around unit - 1 inch
(25mm) each side, 3 inches (76mm) in the rear, 3 inches
(76mm) inches above wall.
This chiller has been designed for use with potable water
ONLY.
LEGEND
A= 1/4" (6mm) O.D. TUBE WATER OUT
B = 1/4" (6mm) O.D. TUBE WATER INLET
C=TEMPERATUREADJUSTMENT
D = ELECTRICAL
SJ2
Refrigeration Package
Halsey Taylor Owners Manual
98346C (03/07)
SJ2Q*1A
FORPARTSCONTACTYOURLOCALDISTRIBUTORORVISITOURWEBSITEWWW.HALSEYTAYLOR.COM
2222CAMDENCOURT
OAKBROOK,IL60523
630.574.3500
PRINTEDINU.S.A.
21
15
23
18
3
22
10, 11, 24
4, 5,
6, 7
9
16
17 19 12, 13, 14
*INCLUDES RELAY & OVERLOAD. IF UNDER
WARRANTY, REPLACE WITH SAME COMPRESSOR
USED IN ORIGINALASSEMBLY.
NOTE: All correspondence pertaining to any of the
above water cooler or orders for repair MUST include
model number and serial number of cooler, name and
part number of replacement part.
1, 2
8
INSTALLATION
1. It is important to insure proper ventilation. For remote installation a minimum clearance of 6 inches
(152 mm) to the front must be maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear
above the unit.
2. When unit is installed in a kitchen cabinet, two air openings with a minimum of 40 square inches each
(minimum of 75% open area) must be provided in the cabinet. One opening should be in the overhang
of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with
a minimum of 3 inch clearance between the unit and the walls of the cabinet. In addition a minimum 2
inch clearance must be provided between the toe space air opening and front of remote unit.
3. Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply connections as required.
4. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being
connected to chiller. If flushing does not remove all particles, a water strainer should be installed in
supply line.
5. Connect cooler to building supply line with a shut-off valve and install a union connection between the
valve and chiller.
6. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on chiller
serial plate. Never wire compressor directly to the power supply.
START-UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain to which chiller is connected.
Steady stream assures all air removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLESHOOTING&MAINTENANCE
Temperature Control: Factory set at 50°F (+/- 5°) under normal conditions. For colder water, adjust
screw on item no. 3 CW.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or
vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the
compressor overload protector.
Lubrication: Motors are lifetime lubricated.
ACTUATION OF QUICK CONNECT WATER FITTINGS:
Chiller is provided with a lead-free plug which utilizes an o-ring water seal. To remove plug from chiller,
relieve water pressure, pull the collar towards the fitting and pull the fitting off the tube. To install plug,
push fitting straight onto tubing until it reaches a positive stop, approximately 3/4 in. (19mm).
ITEM
NO. PART
NO.
1
2
3
4
5
6
7
8
9*
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
30040C
30039C
31513C
31341C
30824C
42677000
111543043890
66266C
36242C
36236C
35768C
19037000
101516143550
100806740570
66201C
66505C
50930C
23105C
27304C
23107C
23108C
23109C
66301C
36231C
DESCRIPTION
Cover - Electrical Box
Box - Electrical
Control - Cold
Motor - Fan
Fan - Blade
Fan - Bracket
Nut - Hex #6-32
Condenser
Compressor Service Pak
Overload
Cover - Relay
Clip - Compressor Mounting
Stud
Grommet
Drier
Evaporator Assy
Bumper
Cabinet
Baseplate
Panel - Rear (Not Shown)
Panel - Front
Panel- Condenser Mounting
Heat Exchanger
Relay
115V
WIRINGDIAGRAM

This manual suits for next models

2

Other Halsey Taylor Chiller manuals

Halsey Taylor SJ8GRN Installation manual

Halsey Taylor

Halsey Taylor SJ8GRN Installation manual

Halsey Taylor SJ8 Installation manual

Halsey Taylor

Halsey Taylor SJ8 Installation manual

Popular Chiller manuals by other brands

Foster FX Blast Chiller Service manual

Foster

Foster FX Blast Chiller Service manual

Zip HYDROCHILL HC10 Series Installation instructions & user manual

Zip

Zip HYDROCHILL HC10 Series Installation instructions & user manual

Coolzone CZ003 User instructions

Coolzone

Coolzone CZ003 User instructions

Filtrine PCP-500G-60A-WP manual

Filtrine

Filtrine PCP-500G-60A-WP manual

Lennox MCW 192 P manual

Lennox

Lennox MCW 192 P manual

AERMEC NRB Series Installation and maintenance manual

AERMEC

AERMEC NRB Series Installation and maintenance manual

Daikin EWWD120MBYNN installation manual

Daikin

Daikin EWWD120MBYNN installation manual

Daikin WGZ030DW Installation, operation and maintenance manual

Daikin

Daikin WGZ030DW Installation, operation and maintenance manual

Comet XRCA-5001-OA manual

Comet

Comet XRCA-5001-OA manual

Thermo Scientific ThermoFlex900 Installation, operation and maintenance manual

Thermo Scientific

Thermo Scientific ThermoFlex900 Installation, operation and maintenance manual

Buchi F-305 Operation manual

Buchi

Buchi F-305 Operation manual

Polar Refrigeration CB507 instruction manual

Polar Refrigeration

Polar Refrigeration CB507 instruction manual

AERMEC NRL 028-075 Technical manual

AERMEC

AERMEC NRL 028-075 Technical manual

Williams 6CL10T01 Owner's/operator's manual

Williams

Williams 6CL10T01 Owner's/operator's manual

SMC Networks HRW D Series Operation manual

SMC Networks

SMC Networks HRW D Series Operation manual

Multiaqua MAC036-01-N Wiring diagram

Multiaqua

Multiaqua MAC036-01-N Wiring diagram

Alto-Shaam quickchiller QC-3 Operating procedure guide

Alto-Shaam

Alto-Shaam quickchiller QC-3 Operating procedure guide

BlueBox ZETA 2002 3,2 Installation, operating and maintenance manual

BlueBox

BlueBox ZETA 2002 3,2 Installation, operating and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.