III. INSTALLATION
MOUNTING
Cabinets are pre-drilled for wall mounting or mounting on an optional base. Bases are
pre-drilled for securing to the floor. Do not use leveling screws when fastening to the
floor. Changers mounted on bases should be securely fastened to both the floor and the
wall. Fasteners to be used should be recommended by your engineer as to strength and
suitability for floor and wall composition. HAMILTON WILL NOT BE RESPONSIBLE
FOR INJURY DUE TO IMPORPER INSTALLATION.
For mounting in the wall, cabinet size is 36-3/8”H x 9-15/16”W x 13’1/4”D.
ELECTRICAL
The POS-TD Changer operates on 120 VAC, 60 Hz. Unit may be hard-wired with conduit if
desired.
A GROUND FAULT INTERRUPTER IS REQUIRED
. The recommended Ground Fault
Interrupter is sometimes referred to as an ELCI (Equipment Leakage Circuit Interrupter)
and should have the following specifications:
• 120 VAC
• 15 AMP
• 6-10mA trip level
• Should no trip when power is removed from circuit.
A communications cable is necessary to connect the POS system to the POS-TD Changer.
This cable is not provided. The required cable is a s andard DB9 Male o DB9
Female serial cable wired s raigh hrough. This cable can be found at most
electronics and appliance stores, as well as most mail order computer companies.
To install the cable, connect the Male end of the cable to the back of the POS-TD Changer,
and the Female end to the serial port on the POS system. Be sure to tighten all of the
screws to avoid accidental unplugging of the connectors.
The total length of the serial communications line between the
Hamilton POS-TD and the store POS should not exceed 50 feet.
COMPUTER SOFTWARE
A diskette is provided with your POS-TD Changer. This diskette contains several files
needed for communications with the POS system and also an installation program.
This disk should be passed on to your systems integrator for proper installation and
configuration of the required files. If the systems integrator is not familiar with this
software already, he should contact Hamilton and request the document “Interfacing with
Hamilton C2000SI Controllers”. This document provides a more detailed explanation of
the requirements and operation of the provided software.