HandyHeat GSM User manual

E
xsamples of the application
Thank you for choosing GSM - remote-controlled
contact- and surveillance device. Connected to the thermostat
HandyHeat131 it controls the electrical heating system in the house,
cottages, summer houses and caravans.
The communication to the device is performed by SMS text from
up to 6 mobile phones, one of which is the master number. At the
same time up to 6 people can control and surpervise the system.
- Temperature control
- Free of charge burglar alarm
- Remote readout of room temperatur
- Remote surveillance of water pipes
Start-up of HandyHeat GSM
A SIM-card is not included in the set so it should be bought separa-
tely and with the option to top-up its account.
Unlock of SIM-card:
SIM card should be unlocked,i.e. one should just delete the PIN-
code. The SIM-card should be put in the moble phone and in the
menu the PIN-code should be deleted. Afterwards the SIM-card is
put back to the HandyHeat GSM.
Change / RESET of masternumber
When a new SIM-card is used or the numbers on the SIM-card are
doubtful, the SIM-card itself can be reset. Leave the SIM-card in
the holder, remove the battery and switch off the current. Press the
RESET button in the upper right corner for 3 seconds. Afterwards
SMS with the text OUTPUT=00 is sent from the master number.
From now on the master number has the place NUM 1 in the me-
mory. Nobody else has access to the device before Service num-
bers are typed in. The service numbers get the places from NUM 2
til NUM 5.
Start-up:
When the device is activated the text with an actual status is sent
to all the numbers from the list in the SIM-card (first 6 numbers
in the memory of the SIM-card ) and the alarm is activated.
By the command ”LANGAUGE=1” the language number 1
is chosen, e.g. Danish.
By the command ”LANGAUGE=2” the language number 2
is chosen, e.g. English.
By the command ”LANGAUGE=3” the language number 3
is chosen, e.g. Spanish.
By the command ”LANGAUGE=4“ the language number 4
is chosen, e.g. Turkish.
By the command ”LANGAUGE=5” the language number 5
is chosen, e.g. Swedish.
By the command ”LANGAUGE=6” the language number 6
is chosen, e.g. Finnish.
The device reports with the text ” Language number=x” where
x is a number of the chosen language.
NB: Use only CAPITAL LETTERS in the text of SMS.
Alarm:
When alarm is activated the actual status of entrances is saved.
If the entrace data is changed an alarm SMS is sent with all the
changes. At the same time alarm is deactivated and the coming
changes cannot be registered. This SMS is sent to all numbers in
the list. By the start-up the alarm is activated.
GSM
Instruction manual
DANSK VARMEKABEL A/S
DANSK VARMEKABEL A/S
Language settings
SMS command Function SMS
report
Outcome
position
Relay
position
1 TEMP Read out the temperature
room
temp= xx.xC
2 HEAT ON Heating is on.
Temperature is acoording
to the thermostat´s settings.
? HEAT ON
No signal on
Pilot wire exit
Relay 1
deactivated /
Relay 2 deactiv.
3 HEAT OFF Heating is off. ? HEAT OFF
Positive
half of periods on
Pilot wire exit
Relay 1
deactiv. / Relay
2 activated
4 NIGHT Temperature is sinking for
3,5 degrees.
? NIGHT Positive/negative
periods on Pilot
wire exit
Relay 1 activat.
/ Relay 2
activated
5 FROST Sinking of the temperature
for 7 degrees.
? FROST Negative
half of periods on
Pilot wire exit
Relay 1 activat.
/ Relay 2
deactivated
6 ALARM ON Air sensor is activated ? ALARM ON
The text message is
sent with activating
an entrance
7 ALARM OFF
Air sensor is deactivated. ?ALARM OFF
The text message is
sent with activating
an entrance
By activating of
entrance (e.g. 2) and
alarm is connected
Alarm alarm=in2
changed !!
ALARM
OFF !!
Message to the device Answer from the device Explanation
STATUS
status=HEAT ON /
ALARM ON
/out3 off/out4
off/in1 off/in2 off/in3 off/in4
off/main on (11.1V)
/Signal=24
This is the message, that informs about the actual status
of the system for the moment it is sent. It is usually used
as a report for the receiving messages. It is send auto-
matically to all the numbers from the list. (11.1V) means
that there is a net service. If the battery is in use it should
be minimum7.0V otherwise the system will stop workin
g
Signal=24 means that there is a cover for 24 at the mo-
ment by the scale from 0 til 30. The signal under 10 is
not so good.
SETNUM=2+4512345678
Encoding of the service number +45 12345678 for
plce 2 in the memory list. “+”is obligatary before the
landline code. Place 1 is taken by the master number.
DELNUM=2
Example for deleting of the service number 2
LISTNUM
Svar 1: NUM 2=+4512345678
Svar 2: NUM 3=00
Svar 3: NUM 4=00
Svar 4: NUM 5=00
Svar 5: NUM 6=EMPTY
5 text messages are sent to the master number informing
what service number are in the memory list of the SIM-
card. The service number 2 is with the Danish landline
code +45 and telephone number 12345678.The numbers
from 2 til 4 are deleted and number 5 is empty.
LANGAUGE=1 Language number=1 Language settings. 1 Danish
LANGAUGE=2 Language number=2 Language settings. 2 English
no main! running on battery
(max 1 hour)(08.8V)
If the network disappears the text message is sent to all
the numbers from the list. To save the energy all relays
are deactivated. There is only 1 hour work capacity on
the internal battery. SMS is sent when network is back.
Thank you for choosing GSM - remote-controlled
contact- and surveillance device. Connected to the thermostat
HandyHeat 131 it controls the electrical power system in the house,
cottages, summer houses and caravans.
The communication to the device is performed via SMS text from
up to 6 mobile telephones, one of which is the master number. At the
same time up to 6 people can control and supervise the system.
Instructions
GSM Modem
Installation instructions
DANSK VARMEKABEL A/S
DANSK VARMEKABEL A/S
Model: HandyHeat GSM
Supply voltage: 230 VAC 50 Hz
Storage: -20°C to 50°C
Protection: Class 2
Housing: IP20 DIN Modul
Enviroment: ROHS
Terminals for cables wire 0,33 to 4 mm2
Back-up battery: 9 volt NiMH (option)
Consumption: max. 125 mA
Accurancy of temperature sensor: -/+ 0,5 C
Mechanical dimentions:
58 x 85 x 157 mm without antenna/aerial.
EMC/CE: EMC-directive 89/336/336/EEC
EN6100-6-1
EN6100-6-2
EN6100-6-3
Technical data
Supply voltage 230 VAC:
Phase (L) MUST be connected to terminal 1
Neutral (N) MUST be connected to terminal 3
Room temperature sensor:
is connected to terminal 39 and 40 randomly
Pilot wire:
exit for connection for HandyHeat 131 thermostats.
Up to 50 thermostats can be connected to the device.
Relay 3 and 4:
Relay exit, which is ‘Normaly Open’,contacts max.
10A voltage
Input 1 till 4
Potentialfree inputs with common minus in
terminal 22
12 V DC exit
-12 volt exit at terminal 32 (set)
+12 volt exit at terminal 33
Maximal load: 100 mA
Placing
Installation:
It should be installed in the electrical dashboard
Fixing:
It is installed on the DIN rail. 12 modules are loaded.
Battery:
Only a rechargeable battary can be used.
Connection of the adjuncts:
Connection of the adjuncts, such as room sensor and
PIR sensor, must be performed BEFORE the devicre is
connected to 230 VAC.
Installation of PIR sensor
See connection instructions
Lundagervej 102
DK-8722 Hedensted
Denmark
Tel. +45 7675 8030
Fax +45 7675 8032
Email: [email protected]
www.handyheat.dk
Product of Denmark
DANSK VARMEKABEL A/S
12 13 14 1513 17 18 19 20 22 23 24 25
32 33 35 36 37 39 40
HANDY HEA T
GSM MOD EM Battery
SIM
Phase(L)
iWtoliPer
Neutral(N)
CN
CN
CN
catnoc3ay
l
eR1t
catnoc3ay
l
eR2t
catnoc4ay
l
eR1t
c
at
n
o
c
4
ay
l
e
R2t
Common input
4Input +
3Input +
2Input +
1
Input +
26
oV21-tu
tuoV21+
CN
CN
CN
rPr
oolF ebo
rProolFebo
SIM
card
Connection
Reset
12 13 14 1513 17 18 19 20 22 23 24 25
32 33 35 36 37 39 40
HANDY HE AT
GSM MOD EM Battery
SIM
Ph e(L)sa
Neutral (N)
26
Connection of PIR sensor (Input 1)
PIR sensor
D
N
G
Vcc
oN
m
m
o
Cno
cN
Working status / Trouble shooting
Pilot lamp:
No light: no supply voltage
Constant light: during start-up 30 - 240 seconds
no SIM card inside
1 flash + pause: Normal function with the master
number; Good aerial covering
2 flash + pause: Normal function with the master
number; Bad aerial covering
3 flash + pause: Function without master number
Good aerial covering
4 flash + pause: Work without master number
Bad aerial covering
Constant flash: Battery function

Popular Heating System manuals by other brands

Watts HKV Push'n'Go Series Installation and operating manual

Watts

Watts HKV Push'n'Go Series Installation and operating manual

Daikin DCC Series installation instructions

Daikin

Daikin DCC Series installation instructions

Helios KWL EC 270 W L Installation and operating instructions

Helios

Helios KWL EC 270 W L Installation and operating instructions

Immergas SUPER TRIO Instructions and warnings

Immergas

Immergas SUPER TRIO Instructions and warnings

aerauliqa QR400A Installation, use & maintenance manual

aerauliqa

aerauliqa QR400A Installation, use & maintenance manual

Valeo Thermo AC 070 Workshop manual

Valeo

Valeo Thermo AC 070 Workshop manual

Galletti REKO 06 Installation - use - maintenance

Galletti

Galletti REKO 06 Installation - use - maintenance

Toyostove Laser 30 Type B user guide

Toyostove

Toyostove Laser 30 Type B user guide

Paul FOCUS 200 Base Translation of the original instruction manual

Paul

Paul FOCUS 200 Base Translation of the original instruction manual

NuAire MRXBOXAB-ECO2B-AE installation manual

NuAire

NuAire MRXBOXAB-ECO2B-AE installation manual

Roca LAIA GTI Operating, cleaning and maintenance instructions

Roca

Roca LAIA GTI Operating, cleaning and maintenance instructions

LG Multi V Water 5 manual

LG

LG Multi V Water 5 manual

Bryant ZONEBB3Z Installation and operating instructions

Bryant

Bryant ZONEBB3Z Installation and operating instructions

flamco Flexcon C/K Installation and operating instruction

flamco

flamco Flexcon C/K Installation and operating instruction

Ferroli UT REC+ Installation, use and maintenance manual

Ferroli

Ferroli UT REC+ Installation, use and maintenance manual

Riello 20083503 manual

Riello

Riello 20083503 manual

International Thermal Research Diesel and AC Heating System for Recreational Vehicles and... Installation and operating manual

International Thermal Research

International Thermal Research Diesel and AC Heating System for Recreational Vehicles and... Installation and operating manual

ibidi Universal Fit 10918 instruction manual

ibidi

ibidi Universal Fit 10918 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.