• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
HI701
To save the battery, the instrument shuts down after 2 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Tips for an Accurate Measurement
Battery Management
Recommendations for Users
Accessories
Reagent Sets
HI701-25 Reagents for 25 Free Chlorine tests
Other Accessories
HI701-11 Free Chlorine Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST701 06/18
HI701 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Any variation
introducedbythe usertothe suppliedequipmentmay degradethemeter's performance.Toavoid
damages or burns, do not put the meter in microwave oven. For yours and the meter's safety
do not use or store the meter in hazardous environments.
www. .com information@itm.com1.800.561.8187
• Turn the meter on by pressing the button. All
segments are displayed. When the display
shows “Add”, “C.1” with “Press” blinking,
the meter is ready.
• Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
• Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
• Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI701-0 reagent. Replace the cap
and shake gently for 20 seconds. Replace the
cuvette into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 1 minute and press the
button.
• The instrument displays the concentration of
free chlorine in ppm. The meter automatically
turns off after 2 minutes.
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you use
the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI701 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0.00 to 2.50 ppm
Resolution 0.01 ppm
Accuracy ±0.03 ppm ±3% of reading @25 °C/77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method Adaptation of USEPA method 330.5. The reaction between free
chlorine and the DPD reagent causes a pink tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 2 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications
www. .com information@itm.com1.800.561.8187

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 253 User manual

Hanna Instruments

Hanna Instruments HI 253 User manual

Hanna Instruments HALO 2 HI9810352 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810352 User manual

Hanna Instruments HI97711 User manual

Hanna Instruments

Hanna Instruments HI97711 User manual

Hanna Instruments HI 98140 User manual

Hanna Instruments

Hanna Instruments HI 98140 User manual

Hanna Instruments edge DO User manual

Hanna Instruments

Hanna Instruments edge DO User manual

Hanna Instruments HI 2550 User manual

Hanna Instruments

Hanna Instruments HI 2550 User manual

Hanna Instruments HI97715 User manual

Hanna Instruments

Hanna Instruments HI97715 User manual

Hanna Instruments HI 96739 User manual

Hanna Instruments

Hanna Instruments HI 96739 User manual

Hanna Instruments HI 96734C User manual

Hanna Instruments

Hanna Instruments HI 96734C User manual

Hanna Instruments HI 96831 User manual

Hanna Instruments

Hanna Instruments HI 96831 User manual

Hanna Instruments HI 95771C User manual

Hanna Instruments

Hanna Instruments HI 95771C User manual

Hanna Instruments HI 8732 User manual

Hanna Instruments

Hanna Instruments HI 8732 User manual

Hanna Instruments HI 9812-0 User manual

Hanna Instruments

Hanna Instruments HI 9812-0 User manual

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments HI727 User manual

Hanna Instruments

Hanna Instruments HI727 User manual

Hanna Instruments Checker HI716 Instruction Manual

Hanna Instruments

Hanna Instruments Checker HI716 Instruction Manual

Hanna Instruments HI96739C User manual

Hanna Instruments

Hanna Instruments HI96739C User manual

Hanna Instruments HI97726 User manual

Hanna Instruments

Hanna Instruments HI97726 User manual

Hanna Instruments HI 93752 User manual

Hanna Instruments

Hanna Instruments HI 93752 User manual

Hanna Instruments HI 93735 User manual

Hanna Instruments

Hanna Instruments HI 93735 User manual

Hanna Instruments HI 93718 User manual

Hanna Instruments

Hanna Instruments HI 93718 User manual

Hanna Instruments HI 96750 User manual

Hanna Instruments

Hanna Instruments HI 96750 User manual

Hanna Instruments HI97106 User manual

Hanna Instruments

Hanna Instruments HI97106 User manual

Hanna Instruments HI736 User manual

Hanna Instruments

Hanna Instruments HI736 User manual

Popular Measuring Instrument manuals by other brands

Viavi MPOL*-85P user guide

Viavi

Viavi MPOL*-85P user guide

Agilent Technologies N9010AK-REA installation guide

Agilent Technologies

Agilent Technologies N9010AK-REA installation guide

Dwyer Instruments UTG Installation and operating instructions

Dwyer Instruments

Dwyer Instruments UTG Installation and operating instructions

RMG EC 900 operating instructions

RMG

RMG EC 900 operating instructions

CPS AC750 Operation manual

CPS

CPS AC750 Operation manual

Datakom DSD-080 user manual

Datakom

Datakom DSD-080 user manual

SJ MXB quick start guide

SJ

SJ MXB quick start guide

Omnitronic DB-100B user manual

Omnitronic

Omnitronic DB-100B user manual

Klemsan Klea 320P-D user manual

Klemsan

Klemsan Klea 320P-D user manual

CLA-VAL X144D e-FlowMeter Quick Start Installation & Removal Instructions

CLA-VAL

CLA-VAL X144D e-FlowMeter Quick Start Installation & Removal Instructions

GLI International P53 Operating instructions manual

GLI International

GLI International P53 Operating instructions manual

Apera Instruments LabSen 243-6 user manual

Apera Instruments

Apera Instruments LabSen 243-6 user manual

Campbell 108 instruction manual

Campbell

Campbell 108 instruction manual

Tektronix 495 Operator's manual

Tektronix

Tektronix 495 Operator's manual

TSI Instruments 4000 Series Design guide

TSI Instruments

TSI Instruments 4000 Series Design guide

geo-FENNEL FL 510HV-G TRACKING user manual

geo-FENNEL

geo-FENNEL FL 510HV-G TRACKING user manual

3M LM1 Charging Instructions

3M

3M LM1 Charging Instructions

Blue-White F-300 quick start guide

Blue-White

Blue-White F-300 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.