Hanna Instruments HI 702 User manual

Copper High Range
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 702 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• HI 702-25 Reagents for 25 tests
• 1 x 1.5V AAA Battery
• Instruction Manual and Quick Reference
HI 702
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs
less light than the zero reference. Check the procedure and make sure
you use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
www.hannainst.com
Technical specifications:
Range 0.00 to 5.00 ppm
Resolution 0.01 ppm
Accuracy ±0.05 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 575 nm
Light Detector Silicon Photocell
Method Adaptation of the EPA approved method. The reaction
between copper and the bicinchoninate reagent causes
a purple tint in the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 64 g (2.3 oz.)
•Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI 702-0 reagent. Replace the
cap and shake gently for about 15 seconds.
Place the cuvette back into the meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement)
or, alternatively, wait for 45 seconds and
press the button.
•The instrument displays the concentration in
ppm of copper. The meter automatically turns
off after 10 minutes.
10 mL
REAGENT SETS
HI 702-25 Reagent for 25 Copper High Range Tests
OTHER ACCESSORIES
HI 702-11 Copper HR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Black Cuvette Cap for Checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvettes cleaning solution (230 mL)
Recommendations for Users
For additional information, contact your
dealer or the nearest
Hanna Customer Service Center.
To find a Hanna Office in your area,
visit our web site:
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
IST702 06/15
Measurement procedure: Accessories:Tips for an accurate measurement
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments Checker HI 723 User manual

Hanna Instruments

Hanna Instruments Checker HI 723 User manual

Hanna Instruments HI 93731 User manual

Hanna Instruments

Hanna Instruments HI 93731 User manual

Hanna Instruments HI 141 Series User manual

Hanna Instruments

Hanna Instruments HI 141 Series User manual

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments

Hanna Instruments Conmet1 (HI 98305 User manual

Hanna Instruments HI 847492 User manual

Hanna Instruments

Hanna Instruments HI 847492 User manual

Hanna Instruments HI 221 User manual

Hanna Instruments

Hanna Instruments HI 221 User manual

Hanna Instruments HI 93719 User manual

Hanna Instruments

Hanna Instruments HI 93719 User manual

Hanna Instruments HI 8014 User manual

Hanna Instruments

Hanna Instruments HI 8014 User manual

Hanna Instruments HI 93751 User manual

Hanna Instruments

Hanna Instruments HI 93751 User manual

Hanna Instruments HI 99161 User manual

Hanna Instruments

Hanna Instruments HI 99161 User manual

Hanna Instruments HI 254 User manual

Hanna Instruments

Hanna Instruments HI 254 User manual

Hanna Instruments HI705 User manual

Hanna Instruments

Hanna Instruments HI705 User manual

Hanna Instruments HI97725 User manual

Hanna Instruments

Hanna Instruments HI97725 User manual

Hanna Instruments HI 9812 User manual

Hanna Instruments

Hanna Instruments HI 9812 User manual

Hanna Instruments HI 9219 User manual

Hanna Instruments

Hanna Instruments HI 9219 User manual

Hanna Instruments HI 9828 User manual

Hanna Instruments

Hanna Instruments HI 9828 User manual

Hanna Instruments HI 755 User manual

Hanna Instruments

Hanna Instruments HI 755 User manual

Hanna Instruments HI 8314 User manual

Hanna Instruments

Hanna Instruments HI 8314 User manual

Hanna Instruments HI 9143 User manual

Hanna Instruments

Hanna Instruments HI 9143 User manual

Hanna Instruments HI 5421 User manual

Hanna Instruments

Hanna Instruments HI 5421 User manual

Hanna Instruments HI 991003 User manual

Hanna Instruments

Hanna Instruments HI 991003 User manual

Hanna Instruments HI 991002 User manual

Hanna Instruments

Hanna Instruments HI 991002 User manual

Hanna Instruments HI97729 User manual

Hanna Instruments

Hanna Instruments HI97729 User manual

Hanna Instruments HI 83099 User manual

Hanna Instruments

Hanna Instruments HI 83099 User manual

Popular Measuring Instrument manuals by other brands

AEMC MN353 user manual

AEMC

AEMC MN353 user manual

Eickemeyer LIFEVET O2 user manual

Eickemeyer

Eickemeyer LIFEVET O2 user manual

Giropes GI620 COMPACT user manual

Giropes

Giropes GI620 COMPACT user manual

Megger DCM340 user guide

Megger

Megger DCM340 user guide

TINRS Edgecutter manual

TINRS

TINRS Edgecutter manual

Bender PEM353 quick start guide

Bender

Bender PEM353 quick start guide

Knick SensoGate WA 131 H user manual

Knick

Knick SensoGate WA 131 H user manual

3M The Edge quick start guide

3M

3M The Edge quick start guide

Campbell LI200R instruction manual

Campbell

Campbell LI200R instruction manual

GE SimpliNano Original instructions

GE

GE SimpliNano Original instructions

Balmac 205ce Operation manual

Balmac

Balmac 205ce Operation manual

Shanghai Grandway Telecom Tech. Co., Ltd. FHP12 user guide

Shanghai Grandway Telecom Tech. Co., Ltd.

Shanghai Grandway Telecom Tech. Co., Ltd. FHP12 user guide

Nikon Nivo Series instruction manual

Nikon

Nikon Nivo Series instruction manual

Elma Instruments RT606 A user manual

Elma Instruments

Elma Instruments RT606 A user manual

Minolta SPOTMETER F - IR REMOTE CONTRO LRC-3 manual

Minolta

Minolta SPOTMETER F - IR REMOTE CONTRO LRC-3 manual

Megger DLRO-10 user guide

Megger

Megger DLRO-10 user guide

iSTEK K100-TB instruction manual

iSTEK

iSTEK K100-TB instruction manual

AITE ATC1006A Operation manual

AITE

AITE ATC1006A Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.