Instruction Manual
HI 93708
Nitrite High Range ISM
http://www.hannainst.com ThisInstrumentisin
Compliancewith the CE Directives
HannaInstrumentsreservestherighttomodifythedesign,construction
andappearanceofitsproductswithoutadvancenotice.
WARRANTYWARRANTY
WARRANTYWARRANTY
WARRANTY
HI93708iswarrantedfor two years against defects in workman-
shipand materialswhenusedforits intendedpurposeandmaintained
accordingtoinstructions.
Thiswarrantyislimitedtorepairorreplacementfreeofcharge.
Damages due to accident, misuse, tampering or lack of prescribed
maintenanceare not covered.
Ifserviceis required,contactthedealerfromwhom youpurchasedthe
instrument.Ifunderwarranty, report the model number, dateofpur-
chase,serialnumberandthe nature of the failure. Iftherepairisnot
coveredby the warranty,youwillbe notified ofthechargesincurred. If
theinstrumentistobereturnedtoHannaInstruments,firstobtaina
ReturnedGoodsAuthorizationNumber from the Customer Service de-
partmentand thensenditwith shipmentcostsprepaid.Whenshipping
anyinstrument, makesureitisproperly packagedforcompleteprotec-
tion.
Tovalidate yourwarranty,filloutandreturntheenclosedwarrantycard
within14 daysfromthedateofpurchase.
Allrightsare reserved. Reproduction inwholeor in part isprohibited
without the written consent of the copyright owner, Hanna Instru-
mentsInc.,Woonsocket, Rhode Island, 02895,USA.
DearCustomer,
Thank you for choosing a Hanna product. This manual will
provide you with the necessary information for the correct
operation of the meter. Please read it carefully before using
the meter. If you need additional technical information, do
not hesitate to e-mail us at [email protected].
This instrument is in compliance with directives
EN 50081-1 and EN 50082-1.
Remove the instrument from the packing material and
examine it carefully to make sure that no damage has
occurred during shipment. If there is any damage, notify
your Dealer.
Each Ion Specific Meter is supplied complete with
• 9V Battery
• Two Sample Cuvets and Caps
• One Transport Cap
Note: Conserve all packing material until the instrument
has been observed to function correctly. Any defective
item must be returned in its original packing.
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATIONPRELIMINARY EXAMINATION
PRELIMINARY EXAMINATION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTIONGENERAL DESCRIPTION
GENERAL DESCRIPTION
The HI 93708 meter measures the nitrite (NO2–) content in
water and wastewater in the 0 to 150 mg/L (ppm) range.
Themeter usesan exclusivepositive-locking systemto ensure
that the cuvet is in the same place every time it is placed
into the measurement cell.
The reagents are in powder form and are supplied in
packets. The amount of reagent is precisely dosed to ensure
maximum repeatability.
Display codes aid the user in routine operations.
The meters have an auto-shut off feature that will turn the
instrument off after 10 minutes of non-use.
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONSSPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
Range 0 to 150 mg/L
Resolution 1 mg/L
Accuracy ±4 mg/L ±4% of reading
TypicalEMC ±1 mg/L
Deviation
Light Source Light Emitting Diode @ 585 nm
Method Adaptation of the Ferrous Sulfate method.
The reaction between nitrite and the re-
agent causes a greenish-brown tint in the
sample
Light Detector SiliconPhotocell
Environment 0 to 50°C (32 to 122°F);
max 95% RH non-condensing
Battery Type/Life1 x 9 volt/40 hours
Auto-Shut off After 10' of non-use
Dimensions 180 x 83 x 46 mm (7.1 x 3.3 x 1.8")
Weight 290 g (10 oz.).
REQUIRED REAGENTS
Code Description Quantity
HI 93708-0 Powder reagent 1 packet
REAGENT SETS
HI93708-01 Reagents for 100 tests
HI93708-03 Reagents for 300 tests
This indicates that the meter is in a
ready state and zeroing can be per-
formed.
Sampling in Progress. This prompt ap-
pears each time the meter is performing
a measurement.
This indicates that the meter is in a
zeroed state and measurement can be
performed.
A zero reading was not taken. Insert a
sample before adding reagent and press
ZERO.
Under range. A blinking "0.00" indicates
that the sample absorbs less light than
the zero reference. Check the procedure
and make sure you use the same cuvet
for reference (zero) and measurement.
Over range. A flashing value higher than
themaximumconcentrationreadable(see
specifications) indicates that the sample
absorbs too much light, meaning that
the concentration is too high. Dilute the
sample.
Light over range. The cuvet is not in-
serted correctly and an excess ambient
light is reaching the detector. If the cover
is properly installed, then contact your
dealer or the nearest Hanna Customer
Service Center.
Light under range. The zero sample is
too dark for proper zeroing. If this is not
the case, contact your dealer or the
nearest Hanna Customer Service Center.
The "V" indicates that the battery volt-
age is getting low and the battery needs
to be replaced.
This indicates that the battery is dead
and must be replaced.
Note: once this indication is displayed,
the meter will lockup. Change the bat-
tery to restart.
DISPLAY CODE GUIDEDISPLAY CODE GUIDE
DISPLAY CODE GUIDEDISPLAY CODE GUIDE
DISPLAY CODE GUIDE
V
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDEOPERATIONAL GUIDE
OPERATIONAL GUIDE
ON
OFF
MEASUREMENT PROCEDURE
• Turn the meter on by pressing ON/OFF.
• When the LCD displays “- - -”, it is
ready.
• Fill the cuvet up to 1.5 cm (¾”) below
therimwith 10mLof unreactedsample,
and replace the cap.
• Placethe cuvetinto theholder
and ensure that the notch on
the cap is positioned securely
into the groove.
• Press ZERO and “SIP” will appear on the display.
• Wait for a few seconds and the dis-
playwillshow“-0.0-”. Nowthemeter
is zeroed and ready for measure-
ment.
• Remove the cuvet.
• Add the content of one
packetof HI 93708 re-
agent. Replace the cap
and shake gently.
• Reinsert the cuvet into the in-
strument.
1.5 cm
ZERO
READ
TIMED
• Press READ TIMED and the display will show the count-
down prior to the measurement, or, alternatively wait
for 10 minutes and press READ DIRECT. In both cases
“SIP” will appear during measurement.
• Theinstrument directly displays concentration in mg/L of
nitrite on the Liquid Crystal Display.
• Toconvert the NO2–ionconcentration to NO2–-Nconcen-
tration, divide the reading by a factor of 3.29.
• To convert the NO2–ion to sodium nitrite NaNO2
concentration, multiply the reading by a factor of 1.5.
INTERFERENCES
HI 93708 will not recognize any glycol based samples.
The instruction listed below should be carefully followed
during testing to ensure best accuracy.
• Do not touch the cuvet walls with hands.
• In order to maintain the same conditions during the
zeroing and the measuring phases, it is necessary to
close the cuvet to prevent any contamination.
• Do not let the test sample stand too long after reagent
is added or accuracy will be lost.
• Whenever the cuvet is placed into the measurement cell,
it must be completely free of fingerprints, oil or dirt.
Wipe it thoroughly with HI 731318 or a lint-free cloth
prior to insertion.
• It is important that the sample does not contain any
debris. This would corrupt the readings.
• It is possible to take multiple readings in a row, but it
is recommended that a zero reading be taken for each
sample and that the same cuvet is used for zeroing and
measurement.
• It is important to discard the sample immediately after
the reading is taken because the glass might become
permanently stained.
• Shaking the cuvet can generate bubbles in the sample,
causing higher readings. To obtain accurate measure-
ments, remove such bubbles by swirling or by gently
tapping the vial.
• All the reaction times reported in this manual are
referred to 20°C (68°F). As a general rule of thumb,
they should be doubled at 10°C (50°F) and halved at
30°C(86°F).
TIPS FOR AN ACCURATETIPS FOR AN ACCURATE
TIPS FOR AN ACCURATETIPS FOR AN ACCURATE
TIPS FOR AN ACCURATE
MEASUREMENTMEASUREMENT
MEASUREMENTMEASUREMENT
MEASUREMENT
BATTERY REPLACEMENTBATTERY REPLACEMENT
BATTERY REPLACEMENTBATTERY REPLACEMENT
BATTERY REPLACEMENT
Battery replacement must only take place in a non-hazard-
ous area using a 9V alkaline battery.
Simply slide off the battery cover on the back of the meter.
Detach the battery from the terminals and attach a fresh
9V battery while paying attention to the correct polarity.
Replace the battery and the cover.
9V
SLID
E
OFF
RecommendationsforUsers
Before using these products, make sure that they are entirely suitable for the environ-
mentinwhichtheyareused.
Operationoftheseinstrumentsinresidentialareacouldcauseunacceptableinterferences
toradioandTV equipments, requiring the operatortotakeallnecessary steps to correct
interferences.
Any variation introduced by the user to the supplied equipment may degrade the
instruments'EMCperformance.
Toavoiddamagesorburns,donotperformanymeasurementinmicrowaveovens.
ACCESSORIESACCESSORIES
ACCESSORIESACCESSORIES
ACCESSORIES
REAGENT SETS
HI93708-01 Reagents for 100 tests
HI93708-03 Reagents for 300 tests
OTHER ACCESSORIES
HI710009 Blue rubber boot
HI710010 Orange rubber boot
HI721310 9V battery (10 pcs)
HI731318 Tissue for wiping cuvets (4 pcs)
HI731321 Glass cuvets (4 pcs)
HI731325 Caps for cuvets (4 pcs)
HI93703-50 Cuvets cleaning solution (230 mL).
CE DECLARATIONCE DECLARATION
CE DECLARATIONCE DECLARATION
CE DECLARATION
OF CONFORMITYOF CONFORMITY
OF CONFORMITYOF CONFORMITY
OF CONFORMITY
IST93708R1 06/98
PRINTED IN PORTUGAL

This manual suits for next models

6

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI774 User manual

Hanna Instruments

Hanna Instruments HI774 User manual

Hanna Instruments HI 749 User manual

Hanna Instruments

Hanna Instruments HI 749 User manual

Hanna Instruments HI 93640N User manual

Hanna Instruments

Hanna Instruments HI 93640N User manual

Hanna Instruments HI739 User manual

Hanna Instruments

Hanna Instruments HI739 User manual

Hanna Instruments HI 713 User manual

Hanna Instruments

Hanna Instruments HI 713 User manual

Hanna Instruments 96711C User manual

Hanna Instruments

Hanna Instruments 96711C User manual

Hanna Instruments HI 3512 User manual

Hanna Instruments

Hanna Instruments HI 3512 User manual

Hanna Instruments HI 9023C User manual

Hanna Instruments

Hanna Instruments HI 9023C User manual

Hanna Instruments HI 96801 User manual

Hanna Instruments

Hanna Instruments HI 96801 User manual

Hanna Instruments HI97727 User manual

Hanna Instruments

Hanna Instruments HI97727 User manual

Hanna Instruments HI 98171 User manual

Hanna Instruments

Hanna Instruments HI 98171 User manual

Hanna Instruments C 221 User manual

Hanna Instruments

Hanna Instruments C 221 User manual

Hanna Instruments HI 83748 User manual

Hanna Instruments

Hanna Instruments HI 83748 User manual

Hanna Instruments HI96000 Series User manual

Hanna Instruments

Hanna Instruments HI96000 Series User manual

Hanna Instruments HI97779 User manual

Hanna Instruments

Hanna Instruments HI97779 User manual

Hanna Instruments HI98190 User manual

Hanna Instruments

Hanna Instruments HI98190 User manual

Hanna Instruments HI 93730 User manual

Hanna Instruments

Hanna Instruments HI 93730 User manual

Hanna Instruments HI 99181 User manual

Hanna Instruments

Hanna Instruments HI 99181 User manual

Hanna Instruments HI 95759 User manual

Hanna Instruments

Hanna Instruments HI 95759 User manual

Hanna Instruments HI 83141 User manual

Hanna Instruments

Hanna Instruments HI 83141 User manual

Hanna Instruments HI 93716 User manual

Hanna Instruments

Hanna Instruments HI 93716 User manual

Hanna Instruments HI 9023C User manual

Hanna Instruments

Hanna Instruments HI 9023C User manual

Hanna Instruments HI 4112 User manual

Hanna Instruments

Hanna Instruments HI 4112 User manual

Hanna Instruments HI96716C User manual

Hanna Instruments

Hanna Instruments HI96716C User manual

Popular Measuring Instrument manuals by other brands

Zebra-Tech MEASURING BOARD Operation manual

Zebra-Tech

Zebra-Tech MEASURING BOARD Operation manual

Siemens Siemeca Operating	 instruction

Siemens

Siemens Siemeca Operating instruction

JUMO AQUIS touch P Interface description

JUMO

JUMO AQUIS touch P Interface description

PEAK INSTRUMENTS P-512 user manual

PEAK INSTRUMENTS

PEAK INSTRUMENTS P-512 user manual

HT Instruments HT4011 user manual

HT Instruments

HT Instruments HT4011 user manual

ATIM ACW/SF8-WL-I user guide

ATIM

ATIM ACW/SF8-WL-I user guide

ABERLINK Axiom Too installation manual

ABERLINK

ABERLINK Axiom Too installation manual

Skye APOLLO SKA 400 manual

Skye

Skye APOLLO SKA 400 manual

Metsys ML3 manual

Metsys

Metsys ML3 manual

KPFM X2 user manual

KPFM

KPFM X2 user manual

Sonel MRU-30 user manual

Sonel

Sonel MRU-30 user manual

Tenmars TM-1016 user manual

Tenmars

Tenmars TM-1016 user manual

Herutu 21D-429C instruction manual

Herutu

Herutu 21D-429C instruction manual

Endress+Hauser Prosonic M FMU40 technical information

Endress+Hauser

Endress+Hauser Prosonic M FMU40 technical information

Altana BYK color2view Short instructions

Altana

Altana BYK color2view Short instructions

horiba LAQUAact D-75 Quick manual

horiba

horiba LAQUAact D-75 Quick manual

Omega Volume VII-System Description Operation manual

Omega

Omega Volume VII-System Description Operation manual

ANALOX Sub Mk III F user manual

ANALOX

ANALOX Sub Mk III F user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.