manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments AquaDip User manual

Hanna Instruments AquaDip User manual

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI 991301 User manual

Hanna Instruments

Hanna Instruments HI 991301 User manual

Hanna Instruments Checker HI717 User manual

Hanna Instruments

Hanna Instruments Checker HI717 User manual

Hanna Instruments HI9146-04 User manual

Hanna Instruments

Hanna Instruments HI9146-04 User manual

Hanna Instruments HI96711C User manual

Hanna Instruments

Hanna Instruments HI96711C User manual

Hanna Instruments HI 720 User manual

Hanna Instruments

Hanna Instruments HI 720 User manual

Hanna Instruments HI 93703-11 User manual

Hanna Instruments

Hanna Instruments HI 93703-11 User manual

Hanna Instruments HI96719C User manual

Hanna Instruments

Hanna Instruments HI96719C User manual

Hanna Instruments HI97709 User manual

Hanna Instruments

Hanna Instruments HI97709 User manual

Hanna Instruments HI715 User manual

Hanna Instruments

Hanna Instruments HI715 User manual

Hanna Instruments Ammonia Medium Range User manual

Hanna Instruments

Hanna Instruments Ammonia Medium Range User manual

Hanna Instruments HI 83214 User manual

Hanna Instruments

Hanna Instruments HI 83214 User manual

Hanna Instruments HI 93711 User manual

Hanna Instruments

Hanna Instruments HI 93711 User manual

Hanna Instruments HI 2400 User manual

Hanna Instruments

Hanna Instruments HI 2400 User manual

Hanna Instruments HI 96811 User manual

Hanna Instruments

Hanna Instruments HI 96811 User manual

Hanna Instruments HI 4101 User manual

Hanna Instruments

Hanna Instruments HI 4101 User manual

Hanna Instruments HI 8915 User manual

Hanna Instruments

Hanna Instruments HI 8915 User manual

Hanna Instruments HI 96812 User manual

Hanna Instruments

Hanna Instruments HI 96812 User manual

Hanna Instruments HI 98401 User manual

Hanna Instruments

Hanna Instruments HI 98401 User manual

Hanna Instruments HI 96706C User manual

Hanna Instruments

Hanna Instruments HI 96706C User manual

Hanna Instruments HI 83141V User manual

Hanna Instruments

Hanna Instruments HI 83141V User manual

Hanna Instruments HI774 User manual

Hanna Instruments

Hanna Instruments HI774 User manual

Hanna Instruments HI83300 User manual

Hanna Instruments

Hanna Instruments HI83300 User manual

Hanna Instruments HI96751C User manual

Hanna Instruments

Hanna Instruments HI96751C User manual

Hanna Instruments HI 83225 User manual

Hanna Instruments

Hanna Instruments HI 83225 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

IRIMO 984-6D-1 owner's manual

IRIMO

IRIMO 984-6D-1 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

InstructionManual
AquaDip
Rugged Waterproof
TDS / °C meter
www.hannainst.com
SPECIFICATIONS
Range
0 to 1999 ppm
0.0 to 60.0 °C
Resolution
1 ppm / 0.1°C
Accuracy
±2% f.s. (ppm) / ±0.5°C
Typical EMC
±2% f.s. (ppm) / ±0.5°C
Deviation
TDS Factor
0.5
Calibration
Factory-calibrated
Temperature
Automatic from 0 to 60°C
Compensation
β=2%/°C, T(ref.)=25°C
Battery Type
2 x 1.5V AAA alkaline
Battery Life
1000 hours of continuous use
Auto-off
After 5 minutes of non-use
Environment
0 to 50°C; 100% RH
Dimensions
94 x 38 x 440 mm (3.7 x 1.5 x 17.3’’)
Weight
200 g (7.8 oz.)
Warranty
All Hanna Instruments meters are warranted for two years against defects in
workmanship and materials when used for their intended purpose and main-
tained according to instructions. This warranty is limited to repair or replacement
free of charge. Damages due to accident, misuse, tampering or lack of pre-
scribed maintenance are not covered. If service is required, contact the dealer
from whom you purchased the instrument. If under warranty, report the model
number, date of purchase, serial number and the nature of the failure. If the
repair is not covered by the warranty, you will be notified of the charges in-
curred. If the instrument is to be returned to Hanna Instruments, first obtain a
Returned Goods Authorization number from the Customer Service department
and then send it with shipping costs prepaid. When shipping any instrument,
make sure it is properly packaged for complete protection.
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the environ-
ment in which it is used. Operation of this instrument in residential areas could
cause interference to radio and TV equipment. Any variation introduced by the
user to the supplied equipment may degrade the instrument EMC performance.
To avoid electrical shocks, do not use this instrument when voltage at the
measurement surface exceeds 24 Vac or 60 Vdc. To avoid damage or burns,
do not perform any measurement in microwave ovens.
ISTAQUADIPR2 05/05
Dear Customer,
Thank you for choosing a Hanna product.
Please read this instruction manual carefully before
using the instrument.
If you need additional technical information, do not hesi-
tate to e-mail us at [email protected].
This instrument is in compliance with directives.
TAKING MEASUREMENTS
The meter is factory calibrated for ppm and temeprature.
Press the ON/OFF key to turn
the meter on.
Immerse the probe into the so-
lution to be tested. The minimum
water level must be approx.
of 4½ cm, while the maximum
level has not to exceed the
indicated hole. If possible, tap
the probe to remove any air
bubbles that may be trapped
inside.
Allow for the reading to stabi-
lize. The LCD displays the
ppm reading.
Press the RANGE key to view
the temperature reading.
Press RANGE again to return
to ppm reading.
If the ppm reading is out of range, the “
---
” indication
is displayed. If the temperature reading is out of range,
the “°C” symbol blinks.
HOLD FUNCTION
To freeze the current measure-
ment on the LCD, press and
hold the RANGE/HOLD key for
about 3 seconds.
When the hold function is active, the LCD displays
alternatively the
“HLd”
indication and the frozen read-
ing.
Press RANGE to switch from ppm to temperature
reading.
Press the ON/OFF key to exit the hold mode and
return to normal operation.
BATTERY REPLACEMENT
To prolong the battery life, the meter switches itself
off after 5 minutes of non-use.
Variations in readings or fading display can indicate
weak batteries.
If the batteries are too weak to support proper opera-
tions, the LCD displays the message “Eb” and then the
meter switches itself off.
Battery replacement must only take place in a non-
hazardous area using 1.5V AAA alkaline batteries.
In order to replace run down
batteries, simply remove the
two screws on the bottom
cover and replace the two
1.5V AAA batteries with new
ones, while paying attention
to the correct polarity.