Hanna Instruments Gro Line HI98318 User manual

INSTRUCTION MANUAL
HI98318
Waterproof EC/TDS Tester
Liquid Crystal
Display
CAL button
Operation
Thank You
Thank you for choosing a Hanna Instruments product. Please read
this instruction manual carefully before using the instrument.
For more information about Hanna and our products,
visit www.hannainst.com or e-mail us at [email protected].
For technical support, contact your local Hanna office or e-mail us
at tech@hannainst.com
Find your local Hanna office on www.hannainst.com
Preliminary Examination
Remove the meter from the packing material and examine it carefully to make sure
that no damage has occurred during shipment. If noticeable damage is evident, contact
your local Hanna office.
Each meter is supplied with:
• CR2032 battery (1 pc.)
• Storage / Protection sleeve
• Instruction manual
• Quality Certificate
Note: Save all packing material until you are sure that the instrument functions
correctly. All defective items must be returned in the original packaging with the
supplied accessories.
Preparation
The probe is shipped dry. Before using the electrode, remove the protective cap. Then
follow the calibration procedure.
• Turn the tester on by pressing ON/OFF button.
• Remove the protective cap and immerse the tip of the probe in the sample to
be tested.
• Stir gently and wait for a stability tag to disappear.
• The electrode automatically compensates for temperature variations.
• The reading on display is directly expressed in: mS/cm or ppm.
• For best results, recalibrate periodically.
• After use rinse the probe with water.
• Always replace the protective cap after each use.
Specifications
TDS Conversion factor
(CF)*
0.5 (500 ppm) or
0.7 (700 ppm)
Calibration
Solutions
HI50036 HI70031
(Quick Cal) (1.41 mS/cm)
Calibration automatic,single point (1.41 mS/cm)
Quick calibration one point calibration using Quick Cal pH and EC
one point calibration solution HI50036
Temperature
Compensation automatic, 0.0 to 50.0 ºC (32.0 to 122.0 ºF)
Battery type CR2032 Li-Ion 3V (1 pc.)
Battery life approximately 250 hours of continuous use
Environment 0 to 50 ºC (32 to 122 ºF);
RH 100% max
Weight
(without battery) 68 g (2.4 oz.)
ON/OFF button
Temperature
Sensor (inside)
EC Probe
Range EC/TDS
0.00 to 6.00 mS/cm
0 to 3000 ppm (0.5)
0 to 4000 ppm (0.7)
0.0 to 50.0 °C (32.0 to 122.0 °F)
Resolution EC/TDS
0.01 mS/cm
10 ppm (0.5)
10 ppm (0.7)
0.1 °C (0.1 °F)
Accuracy
(@25 °C/77 °F) EC/TDS ±2% F.S.
±0.5 °C (±1.0 °F)
All rights are reserved. Reproduction in whole or in part is prohibited
without the written consent of the copyright owner. Hanna Instruments reserves the right to modify the design,
construction, or appearance of its products without advance notice.
*1000 µS/cm =500 ppm with 0.5 CF
• Quick Cal pH and EC one point calibration solution sachet (4 pcs.)
2. Place the probe in calibration solution. The probe tip should be centered in the
solution and submersed 1.18” (3 cm). The meter will automatically recognize the
solution.
3. If the solution is not recognized or is out of the accepted range “---- Err“ is
displayed.
4. If the buffer is recognized “REC“ is displayed until the reading is stable and the
calibration is accepted.
• After acceptance, the “Stor“ message is displayed and meter returns to
measurement mode.
Clear Calibration
Place meter in calibration mode. Press ON/OFF and “Clr” is displayed. The meter will
now be at default calibration.
Quick Calibration
Select calibration type “CAL quic “ from meter setup.
• Enter calibration mode.
• Immerse the probe in the HI50036 calibration solution.
• When the standard values is recognized and stability is reached the meter
automatically accepts the calibration.
• The LCD will display “Stor“ for 1 second and return to normal measurement mode.
• If the standard is not recognized or the slope is out of accepted range “----Err‘ is
displayed. Change the calibration solution, clean the electrode or press any key
to exit calibration.
Error message
During user calibration, if the reading is out of the accepted range, the meter will
display “---- Err“.i.e. 3000 ppm blinking means the limit of the measured value is
out of range.
If the measured temperature is higher than 50.0 ºC or lower than 0.0 ºC, the 50.0 ºC or
0.0 ºC temperature value will blink on the LCD in measure mode.
Operational Guide
To turn the meter ON and check the battery status
Press the ON/OFF button to turn the meter on. At start-up, all the LCD segments are
displayed for 1 second, then the percent indication of the remaining battery life is
displayed for another second. The meter then enters the normal measuring mode.
Note: Keeping the ON/OFF button pressed while turning the meter on will
display all LCD segments as long as the button is pressed.
To enter calibration mode
Press the CAL button. “CAL“ message is displayed.
To enter setup mode
Remove the battery cover and press the Setup button located on the side of the battery.
Meter Setup
While in measurement mode, remove the battery cover. Press the Setup button located
on the side of the battery in the battery compartment. The meter will enter in setup
mode. Press the ON/OFF button to move through setup parameters. Change option by
pressing CAL button. The default settings are: Set t measure unit - °C, AOFF - 8 min,
CAL - standard and EC unit.
To select the temperature unit (°C/°F)
To select the temperature unit when “SET t” is displayed press the CAL button to
change between °C or °F.
To select the Auto-Off time
To select the AUTO OFF when “AOFF” is displayed press the CAL button to change
between 8 min, 60 min or --- (disabled).
To select calibration type
To select calibration type when “CAL“is displayed press the CAL button to choose from
“CAL STD“ (standard calibration) or “CAL quick “(one-point quick calibration).
To select EC or TDS
To select TDS measurement with 0.5 TDS factor press CAL button until “ppm 500 UNIT“ is
displayed. To select TDS measurement with 0.7 TDS factor press CAL button until “ppm
700 UNIT“ is displayed. By pressing CAL button again “mS/cm EC UNIT“ is selected.
To return to measurement mode
Press the ON/OFF button.
To obtain the highest accuracy for measurements it is important to follow these tips:
• Calibration is only as good as the solution being used. The calibration solution
values change over time. Fresh solution should be used for each calibration.
• The probe should be rinsed with purified water each time before placing in
calibration solution or sample to be tested.
Care and Maintenance
Battery Replacement
Setup
Button
Warranty
These meters are warranted for a period of one year against defects in workmanship
and materials when used for their intended purpose and maintained according to
instructions. Probes are warranted for a period of six months. This warranty is limited
to repair or replacement free of charge. Damage due to accidents, misuse, tampering or
lack of prescribed maintenance is not covered. If service is required, contact your local
Hanna office. If under warranty, report the model number, date of purchase, serial
number and the nature of the problem. If the repair is not covered by the warranty,
you will be notified of the charges incurred. If the instrument is to be returned to
Hanna Instruments, first obtain a Returned Goods Authorization (RGA) number from
the Technical Service department and then send it with shipping costs prepaid. When
shipping any instrument, make sure it is properly packaged for complete protection.
Before using Hanna products, make sure that they are entirely suitable for your
specific application and for the environment in which they are used. Operation of these
instruments may cause unacceptable interferences to other electronic equipment,
thus requiring the operator to take all necessary steps to correct such interferences.
Any variation introduced by the user to the supplied equipment may degrade the
instrument’s EMC performance. To avoid damages or burns, do not put the instrument
in microwave oven. For yours and the instrument safety do not use or store the
instrument in hazardous environments.
Recommendations for Users
Solutions
Code Description
HI5036-023
Quick Cal pH and EC one-point
calibration solution,
230 mL bottle
HI50036P
Quick Cal pH and EC one-point
calibration solution,
20 mL sachets (25 pcs.)
HI70031P 1413 µS/cm calibration solution,
20 mL sachets (25 pcs.)
HI7031L 1413 µS/cm calibration solution,
500 mL bottle
HI8031L 1413 µS/cm calibration solution,
500 mL bottle
Accessories
IST98318 07/16-1
Measurement and Calibration
For better accuracy, frequent calibration of the meter is recommended. In addition,
the instrument must be recalibrated:
• When high accuracy is required.
• At least once a month.
Measurement
Press the ON/OFF button to turn the meter ON. Place the probe to the desired solution.
The conductivity value, automatically compensated for temperature, will be shown
on the LCD.
The measured temperature will be shown on the secondary LCD.
Note: Before taking any measurement make sure the meter has been calibrated.
• Press CAL button to enter calibration mode from measurement mode.
• The meter will enter the calibration mode, displaying “mS/cm 1.41 USE” with
CAL tag blinking.
1. Pour 2” (5 cm) of standard solution into a container.
• When the calibration procedure is completed, the “CAL“ tag is turned on.
• After entering in the calibration mode and before the point is accepted, it is
possible to quit the procedure and return to the last calibration data by pressing
the CAL button. The LCD displays”----ESC” for 1 second and the meter returns to
measurement mode.
To change the CR2032 Li-ion battery, turn the battery cover located on the back of
the meter counterclockwise to unlock. Remove cover and replace with new battery
+ side facing up.
Note: Batteries should only be replaced in a safe area using the battery
type specified in this instruction manual. Old batteries should be disposed in
accordance with local regulations.
Calibration Procedure
The meter features a low battery indicator. When the battery is running low (under
10%), the battery indicator will blink on the LCD. When the battery is discharged
“dEAd bAtt” will be displayed on the LCD for 2 seconds and the meter will turn off.

Other Hanna Instruments Test Equipment manuals

Hanna Instruments HI 3831T User manual

Hanna Instruments

Hanna Instruments HI 3831T User manual

Hanna Instruments 3815 User manual

Hanna Instruments

Hanna Instruments 3815 User manual

Hanna Instruments HI 3831F User manual

Hanna Instruments

Hanna Instruments HI 3831F User manual

Hanna Instruments HALO2 User manual

Hanna Instruments

Hanna Instruments HALO2 User manual

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments GroLine HI98318 User manual

Hanna Instruments

Hanna Instruments GroLine HI98318 User manual

Hanna Instruments HI 3812 User manual

Hanna Instruments

Hanna Instruments HI 3812 User manual

Hanna Instruments DiST 3 User manual

Hanna Instruments

Hanna Instruments DiST 3 User manual

Hanna Instruments Checker HI772 User manual

Hanna Instruments

Hanna Instruments Checker HI772 User manual

Hanna Instruments Primo Series User manual

Hanna Instruments

Hanna Instruments Primo Series User manual

Hanna Instruments DiST 1 User manual

Hanna Instruments

Hanna Instruments DiST 1 User manual

Hanna Instruments HI719 User manual

Hanna Instruments

Hanna Instruments HI719 User manual

Hanna Instruments PICCOLO 2 HI 98112 User manual

Hanna Instruments

Hanna Instruments PICCOLO 2 HI 98112 User manual

Hanna Instruments HI 38081 User manual

Hanna Instruments

Hanna Instruments HI 38081 User manual

Hanna Instruments HALO 2 HI9810442 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810442 User manual

Hanna Instruments HI 99104 User manual

Hanna Instruments

Hanna Instruments HI 99104 User manual

Hanna Instruments Foodcare HI981038 User manual

Hanna Instruments

Hanna Instruments Foodcare HI981038 User manual

Hanna Instruments PH GROCHEK User manual

Hanna Instruments

Hanna Instruments PH GROCHEK User manual

Hanna Instruments HI98330 User manual

Hanna Instruments

Hanna Instruments HI98330 User manual

Hanna Instruments HI981037 User manual

Hanna Instruments

Hanna Instruments HI981037 User manual

Hanna Instruments HI 93739 User manual

Hanna Instruments

Hanna Instruments HI 93739 User manual

Hanna Instruments HI 38077 User manual

Hanna Instruments

Hanna Instruments HI 38077 User manual

Hanna Instruments HI 38074 User manual

Hanna Instruments

Hanna Instruments HI 38074 User manual

Hanna Instruments HALO2 HI9810352 User manual

Hanna Instruments

Hanna Instruments HALO2 HI9810352 User manual

Popular Test Equipment manuals by other brands

Ossila T2003 user manual

Ossila

Ossila T2003 user manual

az-instrument 8930 Operation manual

az-instrument

az-instrument 8930 Operation manual

DAKOTA ULTRASONICS PR-9 Operation manual

DAKOTA ULTRASONICS

DAKOTA ULTRASONICS PR-9 Operation manual

Itm Elditest CT2982B user manual

Itm

Itm Elditest CT2982B user manual

Netscout OneTouch AT 10G user manual

Netscout

Netscout OneTouch AT 10G user manual

HT MPP300 user manual

HT

HT MPP300 user manual

Mecmesin Helixa Assembly and installation

Mecmesin

Mecmesin Helixa Assembly and installation

Rigol DS1074B user guide

Rigol

Rigol DS1074B user guide

Gallagher W810 v2 user manual

Gallagher

Gallagher W810 v2 user manual

STEP SYSTEMS pH Soil instruction manual

STEP SYSTEMS

STEP SYSTEMS pH Soil instruction manual

DANPHONE Futronic MKII user manual

DANPHONE

DANPHONE Futronic MKII user manual

Komshine KFL-11P Instructions for use

Komshine

Komshine KFL-11P Instructions for use

Beta 1464AP Operation manual and instructions

Beta

Beta 1464AP Operation manual and instructions

Kenwood CAX-AD100 instruction manual

Kenwood

Kenwood CAX-AD100 instruction manual

FLIR VT8-600 user manual

FLIR

FLIR VT8-600 user manual

SKI 18BDC Owner's/operator's manual

SKI

SKI 18BDC Owner's/operator's manual

Sifam Tinsley Insu 5Dx user manual

Sifam Tinsley

Sifam Tinsley Insu 5Dx user manual

Bosch EPS 807 Repair instructions

Bosch

Bosch EPS 807 Repair instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.